A comparative study of the cytotoxicity and corrosion resistance of nickel–titanium and titanium–niobium shape memory alloys
Source abstract
Abstract
Nickel-titanium (NiTi) shape memory alloys (SMAs) are commonly used in a range of biomedical applications. However, concerns exist regarding their use in certain biomedical scenarios due to the known toxicity of Ni and conflicting reports of NiTi corrosion resistance, particularly under dynamic loading. Titanium-niobium (TiNb) SMAs have recently been proposed as an alternative to NiTi SMAs due to the biocompatibility of both constituents, the ability of both Ti and Nb to form protective surface oxides, and their superior workability. However, several properties critical to the use of TiNb SMAs in biomedical applications have not been systematically explored in comparison with NiTi SMAs. These properties include cytocompatibility, corrosion resistance, and alterations in alloy surface composition in response to prolonged exposure to physiological solutions. Therefore, the goal of the present work was to comparatively investigate these aspects of NiTi (49.2 at.% Ti) and TiNb (26 at.% Nb) SMAs. The results from the current studies indicate that TiNb SMAs are less cytotoxic than NiTi SMAs, at least under static culture conditions. This increased TiNb cytocompatibility was correlated with reduced ion release as well as with increased corrosion resistance according to potentio-dynamic tests. Measurements of the surface composition of samples exposed to cell culture medium further supported the reduced ion release observed from TiNb relative to NiTi SMAs. Alloy composition depth profiles also suggested the formation of calcium phosphate deposits within the surface oxide layers of medium-exposed NiTi but not of TiNb. Collectively, the present results indicate that TiNb SMAs may be promising alternatives to NiTi for certain biomedical applications.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Shape Memory Alloy Transformations · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (61)
Show source-provided references
1. The utility of superelasticity in medicine
2. Biomedical applications of shape memory alloys10.1155/2011/501483 ↗
3. Comparative cell culture effects of shape memory metal (nitinol), nickel and titanium: a biocompatibility estimation10.1159/000129231 ↗
4. Tissue reaction in rabbit muscle exposed to metallic implants10.1002/jbm.820010113 ↗
5. Toxicity and carcinogenicity of nickel compounds10.3109/10408448909029327 ↗
6. Nickel sensitivity in the general population10.1111/j.1600-0536.1979.tb05531.x ↗
7. Nickel, chromium, cobalt dental alloys and allergic reactions: an overview10.1016/0142-9612(89)90060-4 ↗
8. Assessing the biocompatibility of NiTi shape memory alloys used for medical applications10.1007/s00216-004-2888-3 ↗
9. Physicochemical and biological aspects of nitinol as a biomaterial10.1179/095066001771048745 ↗
10. Surface corrosion and biocompatibility aspects of nitinol as an implant material
11. In vitro biocompatibility assessment of a nickel–titanium alloy using electron microscopy in situ end-labeling (EM-ISEL)10.1002/(SICI)1097-4636(199807)41:1<154::AID-JBM18>3.0.CO;2-N ↗
12. Corroded nitinol wires in explanted aortic endografts: an important mechanism of failure?10.1177/152660280100800303 ↗
13. The cytotoxicity of corrosion products of nitinol stent wire on cultured smooth muscle cells10.1002/1097-4636(200011)52:2<395::AID-JBM21>3.0.CO;2-B ↗
14. Influence of stent design and material composition on procedure outcome10.1067/mva.2002.129113 ↗
15. What can we learn from explanted endovascular devices?10.1053/ejvs.2002.1677 ↗
16. Martensitic transformations in Ti–(16–26at%) Nb alloys10.1007/BF00356449 ↗
17. Development and characterization of Ni-free Ti-base shape memory and superelastic alloys10.1016/j.msea.2006.02.054 ↗
18. Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium10.1016/S0142-9612(00)00275-1 ↗
19. Cytotoxicity of titanium and titanium alloying elements10.1177/0022034510363675 ↗
20. Cytotoxicity evaluation of 43 metal salts using murine fibroblasts and osteoblastic cells10.1002/(SICI)1097-4636(199802)39:2<331::AID-JBM22>3.0.CO;2-E ↗
21. New developments in jewellery and dental materials10.1111/j.1600-0536.1998.tb05832.x ↗
22. Trends in cardiac pacemaker batteries
23. Structure–property relationship of cast Ti–Nb alloys10.1046/j.1365-2842.2002.00825.x ↗
24. The influence of niobium and vanadium on passivity of titanium-based implants in physiological solution10.1016/S0142-9612(03)00252-7 ↗
25. Corrosion behaviour and biocompatibility evaluation of low modulus Ti–16Nb shape memory alloy as potential biomaterial10.1016/j.matlet.2009.02.062 ↗
26. Martensitic transformation, shape memory effect and superelasticity of Ti–Nb binary alloys10.1016/j.actamat.2006.01.019 ↗
27. Mechanical properties and grindability of dental cast Ti–Nb alloys10.4012/dmj.22.328 ↗
28. Mechanical properties and shape memory behavior of Ti-Nb alloys
29. Ti based biomaterials, the ultimate choice for orthopaedic implants – a review10.1016/j.pmatsci.2008.06.004 ↗
30. Electrochemical and cytocompatibility assessment of NiTiNOL memory shape alloy for orthodontic use10.1016/S1389-0344(02)00041-2 ↗
31. Cytocompatibility of UV and visible light photoinitiating systems on cultured NIH/3T3 fibroblasts in vitro10.1163/156856200743805 ↗
32. Improving the biocompatibility of NiTi alloy by chemical treatments: an in vitro evaluation in 3T3 human fibroblast cell10.1016/j.msec.2007.05.006 ↗
33. Easy assessment of the biocompatibility of Ni-Ti alloys by in vitro cell culture experiments on a functionally graded Ni–NiTi–Ti material10.1016/S0142-9612(02)00200-4 ↗
34. Physical metallurgy of Ti–Ni-based shape memory alloys10.1016/j.pmatsci.2004.10.001 ↗
35. Otsuka · 1998
36. Hydrogel properties influence ECM production by chondrocytes photoencapsulated in poly(ethylene glycol) hydrogels10.1002/jbm.1217 ↗
37. Variable cytocompatibility of six cell lines with photoinitiators used for polymerizing hydrogels and cell encapsulation10.1016/j.biomaterials.2004.04.024 ↗
38. Impact of endothelial cells and mechanical conditioning on smooth muscle cell extracellular matrix production and differentiation10.1089/ten.tea.2008.0179 ↗
39. Probing vocal fold fibroblast response to hyaluronan in 3D contexts10.1002/bit.22436 ↗
40. Effects of sterilization processes on NiTi alloy: surface characterization10.1002/(SICI)1097-4636(200001)49:1<88::AID-JBM11>3.0.CO;2-I ↗
41. Titanium nickelide-based alloys: surface modifications with ion beam, plasma flows and chemical treatment
42. Physiologic pulsatile flow bioreactor conditioning of poly(ethylene glycol)-based tissue engineered vascular grafts10.1007/s10439-006-9099-3 ↗
43. Calcium phosphate naturally formed on titanium in electrolyte solution10.1016/0142-9612(91)90028-9 ↗
44. One-dimensional topography underlies three-dimensional fibrillar cell migration10.1083/jcb.200810041 ↗
45. Optimizing a 3D culture system to study the interaction between epithelial breast cancer and its surrounding fibroblasts10.7150/jca.2.458 ↗
46. Repassivation of titanium and surface oxide film regenerated in simulated bioliquid10.1002/(SICI)1097-4636(19980615)40:4<530::AID-JBM3>3.0.CO;2-G ↗
47. Shabalovskaya S, Rondelli G, Itin V, Anderegg J. Surface and corrosion aspects of NiTi alloys. In: SMST-2000. Proceedings of the international conference on shape memory and superelastic technologies; 2001. p. 299–308.
48. On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys
49. Study of a nitinol stent deployed into anatomically accurate artery geometry and subjected to realistic service loading10.1007/s11665-009-9375-0 ↗
50. Influence of niobium and zirconium alloying additions on the anodic dissolution behavior of activated titanium in HCl solutions10.1149/1.1337605 ↗
51. Corrosion behavior of a low modulus beta-Ti-45%Nb alloy for use in medical implants
52. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel–titanium alloys: a comparative study with commonly used medical grade materials10.1002/jbm.a.31154 ↗
53. Assays of cytotoxicity of the nickel-titanium shape memory alloy
54. Histomorphometric analysis of the response of rat tibiae to shape memory alloy (nitinol)10.1016/S0142-9612(96)00051-8 ↗
55. Biocompatibility testing of NiTi screws using immunohistochemistry on sections containing metallic implants10.1002/(SICI)1097-4636(199610)32:2<243::AID-JBM14>3.0.CO;2-K ↗
56. In vitro cytotoxicity evaluation of a 508% NiTi single crystal10.1002/jbm.a.10134 ↗
57. Heavy metals of relevance to human health induce genomic instability10.1002/path.950 ↗
58. Corrosion resistance improvement of NiTi osteosynthesis staples by plasma polymerized tetrafluoroethylene coating
59. Effect of modification of oxide layer on NiTi stent corrosion resistance10.1002/(SICI)1097-4636(199824)43:4<433::AID-JBM11>3.0.CO;2-# ↗
60. Effect of surface treatment of NiTi alloy on its corrosion behavior in Hanks’ solution10.1002/jbm.10114 ↗
61. Effect of hydroxyapatite coating on nickel release of the porous NiTi shape memory alloy fabricated by SHS method10.1016/j.surfcoat.2006.01.015 ↗