journal article·2017-11

Mechanical characterization of structurally porous biomaterials built via additive manufacturing: experiments, predictive models, and design maps for load-bearing bone replacement implants

D. Melancon, Z.S. Bagheri, R.B. Johnston, L. Liu, M. Tanzer, D. Pasini

Acta Biomaterialia· Volume 63
Publisher page

Abstract

Porous biomaterials can be additively manufactured with micro-architecture tailored to satisfy the stringent mechano-biological requirements imposed by bone replacement implants. In a previous investigation, we introduced structurally porous biomaterials, featuring strength five times stronger than commercially available porous materials, and confirmed their bone ingrowth capability in an in vivo canine model. While encouraging, the manufactured biomaterials showed geometric mismatches between their internal porous architecture and that of its as-designed counterpart, as well as discrepancies between predicted and tested mechanical properties, issues not fully elucidated. In this work, we propose a systematic approach integrating computed tomography, mechanical testing, and statistical analysis of geometric imperfections to generate statistical based numerical models of high-strength additively manufactured porous biomaterials. The method is used to develop morphology and mechanical maps that illustrate the role played by pore size, porosity, strut thickness, and topology on the relations governing their elastic modulus and compressive yield strength. Overall, there are mismatches between the mechanical properties of ideal-geometry models and as-manufactured porous biomaterials with average errors of 49% and 41% respectively for compressive elastic modulus and yield strength. The proposed methodology gives more accurate predictions for the compressive stiffness and the compressive strength properties with a reduction of the average error to 11% and 7.6%. The implications of the results and the methodology here introduced are discussed in the relevant biomechanical and clinical context, with insight that highlights promises and limitations of additively manufactured porous biomaterials for load-bearing bone replacement implants. Statement of significance In this work, we perform mechanical characterization of load-bearing porous biomaterials for bone replacement over their entire design space. Results capture the shift in geometry and mechanical properties between as-designed and as-manufactured biomaterials induced by additive manufacturing. Characterization of this shift is crucial to ensure appropriate manufacturing of bone replacement implants that enable biological fixation through bone ingrowth as well as mechanical property harmonization with the native bone tissue. In addition, we propose a method to include manufacturing imperfections in the numerical models that can reduce the discrepancy between predicted and tested properties. The results give insight into the use of structurally porous biomaterials for the design and additive fabrication of load-bearing implants for bone replacement.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Cellular and Composite Structures · Bone Tissue Engineering Materials · Topology Optimization in Engineering

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (69)

Show source-provided references
1. Bone tissue engineering using 3d printing10.1016/j.mattod.2013.11.017 ↗
2. 3d modeling, custom implants and its future perspectives in craniofacial surgery10.4103/2231-0746.133065 ↗
3. A new era in porous metals: Applications in orthopaedics10.1002/adem.200800215 ↗
4. The optimum pore-size for the fixation of porous-surfaced metal implants by the ingrowth of bone10.1097/00003086-198007000-00045 ↗
5. Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial10.1302/0301-620X.81B5.0810907 ↗
6. The correlation of pore morphology, interconnectivity and physical properties of 3d ceramic scaffolds with bone ingrowth10.1016/j.biomaterials.2008.10.056 ↗
7. Next-generation biomedical implants using additive manufacturing of complex, cellular and functional mesh arrays10.1098/rsta.2010.0010 ↗
8. High-strength porous biomaterials for bone replacement: a strategy to assess the interplay between cell morphology, mechanical properties, bone ingrowth and manufacturing constraints10.1016/j.actbio.2015.10.048 ↗
9. Mechanical evaluation of porous titanium (ti6al4v) structures with electron beam melting (ebm)10.1016/j.jmbbm.2009.10.006 ↗
10. Multiscale design and multiobjective optimization of orthopedic hip implants with functionally graded cellular material
11. The fatigue design of a bone preserving hip implant with functionally graded cellular material
12. Producing and avoiding stress shielding - laboratory and clinical observations of noncemented total hip-arthroplasty
13. Fabrication methods of porous metals for use in orthopaedic applications10.1016/j.biomaterials.2005.12.002 ↗
14. Three-dimensional plotted scaffolds with controlled pore size gradients: effect of scaffold geometry on mechanical performance and cell seeding efficiency10.1016/j.actbio.2010.11.003 ↗
15. Engineered tissue scaffolds with variational porous architecture10.1115/1.4002933 ↗
16. Characterization of cellular solids in ti6al4v for orthopaedic implant applications: trabecular titanium10.1016/j.jmbbm.2010.02.001 ↗
17. Scaffold translation: barriers between concept and clinic10.1089/ten.teb.2011.0251 ↗
18. Biomimetic porous scaffolds for bone tissue engineering10.1016/j.mser.2014.04.001 ↗
19. S. Arabnejad, B. Johnston, M. Tanzer, D. Pasini, Fully porous 3d printed titanium femoral stem to reduce stress-shielding following total hip arthroplasty, J. Orthop. Res. (in press). doi:10.1002/jor.23445. https://www.ncbi.nlm.nih.gov/pubmed/27664796.10.1002/jor.23445 ↗
20. Peri- and intra-implant bone response to microporous ti coatings with surface modification10.1016/j.actbio.2013.10.017 ↗
21. Geometry of carriers controlling phenotypic expression in bmp-induced osteogenesis and chondrogenesis
22. The design of scaffolds for use in tissue engineering. part 1. Traditional factors10.1089/107632701753337645 ↗
23. Hierarchical tailoring of strut architecture to control permeability of additive manufactured titanium implants10.1016/j.msec.2013.05.050 ↗
24. Accurate measurement of cortical bone elasticity tensor with resonant ultrasound spectroscopy10.1016/j.jmbbm.2012.09.017 ↗
25. A novel method for biomaterial scaffold internal architecture design to match bone elastic properties with desired porosity10.1016/j.jbiomech.2003.09.029 ↗
26. Mechanical response of ti-6al-4v octet-truss lattice structures10.1016/j.ijsolstr.2015.02.020 ↗
27. Foam topology bending versus stretching dominated architectures10.1016/S1359-6454(00)00379-7 ↗
28. Effective properties of the octet-truss lattice material10.1016/S0022-5096(01)00010-2 ↗
29. Direct metal fabrication of titanium implants with tailored materials and mechanical properties using electron beam melting technology10.1016/j.msec.2007.04.022 ↗
30. Cellular ti-6al-4v structures with interconnected macro porosity for bone implants fabricated by selective electron beam melting10.1016/j.actbio.2008.03.013 ↗
31. Mechanical testing of metals – Ductility testing – Compression test for porous and cellular metals, Standard, International Organization for Standardization, Geneva, CH (Dec. 2011).
32. Network analysis of filter cake pore structure by high resolution x-ray microtomography10.1016/S1385-8947(99)00149-7 ↗
33. Heat treatment of ti6al4v produced by selective laser melting: microstructure and mechanical properties10.1016/j.jallcom.2012.07.022 ↗
34. RENISHAW, Ti6Al4V ELI-0406 powder for additive manufacturing (2016).
35. Standard Test Methods for Tension Testing of Metallic Materials, Standard, ASTM International, West Conshohocken, PA (2016).
36. The shear coefficient in timoshenko’s beam theory10.1115/1.3625046 ↗
37. Mechanical properties of lattice materials via asymptotic homogenization and comparison with alternative homogenization methods10.1016/j.ijmecsci.2013.10.003 ↗
38. Mechanical behavior of additive manufactured, powder-bed laser-fused materials10.1016/j.msea.2015.10.068 ↗
39. Elastic and failure response of imperfect three-dimensional metallic lattices: the role of geometric defects induced by selective laser melting10.1016/j.jmps.2017.07.003 ↗
40. Porous titanium scaffolds fabricated using a rapid prototyping and powder metallurgy technique10.1016/j.biomaterials.2008.05.032 ↗
41. In vivo study of a self-stabilizing artificial vertebral body fabricated by electron beam melting10.1097/BRS.0000000000000211 ↗
42. L.J. Gibson, M.F. Ashby, Cellular Solids: Structure and Properties, Cambridge, 1999.
43. Linear multiscale analysis and finite element validation of stretching and bending dominated lattice materials10.1016/j.mechmat.2011.11.009 ↗
44. Bioactive ti metal analogous to human cancellous bone: Fabrication by selective laser melting and chemical treatments10.1016/j.actbio.2010.09.034 ↗
45. Evaluations of cellular lattice structures manufactured using selective laser melting10.1016/j.ijmachtools.2012.06.002 ↗
46. Numerical investigation on mechanical properties of cellular lattice structures fabricated by fused deposition modeling10.1016/j.ijmecsci.2014.08.009 ↗
47. Mechanical properties of open-cell metallic biomaterials manufactured using additive manufacturing10.1016/j.matdes.2013.01.071 ↗
48. Osteoporosis and biomaterial osteointegration10.1016/j.biopha.2004.08.016 ↗
49. Micro-ct-based improvement of geometrical and mechanical controllability of selective laser melted ti6al4v porous structures10.1016/j.msea.2011.06.045 ↗
50. Porous-coated hip-replacement – the factors governing bone ingrowth stress shielding and clinical-results10.1302/0301-620X.69B1.3818732 ↗
51. A review of the mechanical behavior of cap and cap/polymer composites for applications in bone replacement and repair10.1016/j.actbio.2010.07.012 ↗
52. Compensation strategy to reduce geometry and mechanics mismatches in porous biomaterials built with selective laser melting10.1016/j.jmbbm.2016.04.041 ↗
53. Influence of processing conditions on strut structure and compressive properties of cellular lattice structures fabricated by selective laser melting10.1016/j.msea.2015.01.031 ↗
54. Experimental-determination of friction characteristics at the trabecular bone porous-coated metal interface in cementless implants10.1002/jbm.820270205 ↗
55. Interfacial frictional behavior: cancellous bone, cortical bone, and a novel porous tantalum biomaterial10.1142/S0218957799000269 ↗
56. Experimental and clinical performance of porous tantalum in orthopedic surgery10.1016/j.biomaterials.2006.04.041 ↗
57. Osman, Effects of surface coating on reducing friction and wear of orthopaedic implants10.1088/1468-6996/15/1/014402 ↗
58. Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial10.1302/0301-620X.81B5.0810907 ↗
59. Properties of open-cell porous metals and alloys for orthopaedic applications
60. DePuy Synthes, Product Rationale GRIPTION (2014).
61. Stryker, Tritanium PL Posterior Lumbar Cage Technical Summary (2017).
62. M.R. Dias, J.M. Guedes, C.L. Flanagan, S.J. Hollister, P.R. Fernandes, Optimization of scaffold design for bone tissue engineering: a computational and experimental study, Med. Eng. Phys. 36 (4) 448–457, iSI Document Delivery No.: AF8OZ ISSN = 1350–4533, doi:10.1016/j.medengphy.2014.02.010, URL: ://WOS:000334976800005, year = 2014, type = Journal Article.10.1016/j.medengphy.2014.02.010 ↗
63. Compression deformation behavior of ti6al4v alloy with cellular structures fabricated by electron beam melting10.1016/j.jmbbm.2012.10.005 ↗
64. Additively manufactured metallic porous biomaterials based on minimal surfaces: a unique combination of topological, mechanical, and mass transport properties10.1016/j.actbio.2017.02.024 ↗
65. Methods used to assess implant stability: current status
66. Relationship between unit cell type and porosity and the fatigue behavior of selective laser melted meta-biomaterials10.1016/j.jmbbm.2014.12.015 ↗
67. Preprocessing and postprocessing for materials based on the homogenization method with adaptive finite-element methods10.1016/0045-7825(90)90148-F ↗
68. A comparison of homogenization and standard mechanics analyses for periodic porous composites10.1007/BF00369853 ↗
69. B. Hassani, A direct method to derive the boundary conditions of the homogenization equation for symmetric cells, Communications in Numerical Methods in Engineering 12 (3). doi:10.1002/(SICI)1099-0887(199603)12:3185::AID-CNM9703.0.CO;2-2. doi: 10.1002/(SICI)1099-0887(199603)12:3185::AID-CNM9703.0.CO;2-2.