journal article·2018-02-12

ISFET structures with chemically modified membrane for bovine serum albumin detection

Piotr Firek, Michal Cichomski, Michal Waskiewicz, Ireneusz Piwoński, Aneta Kisielewska

Circuit World· Volume 44· Issue 1
Publisher page

Abstract

Purpose The purpose of this paper is to present possibility of fast and certain identification of bovine serum albumin (BSA) by means of ion-sensitive field effect transistor (ISFET) structures. Because BSA can cause allergic reactions in humans, it is one of reasons for development of sensitive sensors to detect residual BSA. BSA is commonly used in biochemistry and molecular biology in laboratory experiments. Therefore, to better understand the mechanism of signal transduction in simulated biological environment and to elucidate the role of adsorption of biomolecules in the generation of a signal at the interface with biological systems, the measurements of ISFET current response in the presence of BSA as a reference protein molecule were performed. Design/methodology/approach To fabricate transistors, silicon technology was used. The ISFET structures were coupled to specially designed double-side printed circuit board holder. After modification of the field effect transistor (FET) device with 3-aminopropyltriethoxysilane (APTES), a sensor with high sensitivity toward reference biomolecules was obtained. The current–voltage (I-V) characteristics of structures with and without gate modification were measured. Keithley SMU 236/237/238 measurement set was used. Deionized water solution and 0.05 per cent BSA were used. Findings In this research, a method of preparation of a biosensor based on a FET was developed. Sensitivity of APTES-modified FET device toward BSA as a biomolecule was investigated. I-V relationships of FET devices (with and without modification), being the effect of the interactions with the solution containing 0.05 per cent BSA, were measured and compared to the measurements performed for solutions without BSA. Originality value Compared to SiO2-containing ISFETs without modification or other different dielectrics, the application of APTES as the part of the membrane induced significant increase in their sensitivity to BSA.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Analytical Chemistry and Sensors · Electrochemical sensors and biosensors · Water Quality Monitoring and Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Warsaw University of Technology Institute of Microelectronics and Optoelectronics, , Warsaw,

University of Lodz Department of Materials Technology and Chemistry, Faculty of Chemistry, , Lódz,

References (26)

Show source-provided references
1. Open-gated pH sensor fabricated on an Undoped-AlGaN/GaN HEMT structure10.3390/s110303067 ↗
2. Thirty years of ISFETOLOGY what happened in the past 30 years and what may happen in the next 30 years10.1016/S0925-4005(02)00301-5 ↗
3. Capillary sensor with UV-VIS reading of effects of diesel and biodiesel fuel degradation in storage
4. O-terminated nano-diamond ISFET for applications in harsh environment10.1016/j.diamond.2008.01.106 ↗
5. Comparison of different aminofunctionalization strategies for attachment of single antibodies to AFM cantilevers10.1016/j.ultramic.2007.02.035 ↗
6. The Influence of wire bonding on electric characteristics of MIS/ISFET structures
7. Properties of aln thin films deposited by means of magnetron sputtering for ISFET applications10.1515/msp-2015-0095 ↗
8. ISFET based microsensors for environmental monitoring10.3390/s100100061 ↗
9. Detection principles of biological and chemical FET sensors10.1016/j.bios.2017.07.010 ↗
10. Molecular layer deposition of APTES on silicon nanowire biosensors: surface characterization, stability and pH response10.1016/j.apsusc.2014.10.097 ↗
11. Extended-gate field-effect transistor packed in micro channel for glucose, urea and protein biomarker detection
12. Residual bovine serum albumin (BSA) quantitation in vaccines using automated capillary Western technology10.1016/j.ab.2014.05.004 ↗
13. Comparing the ISFET to the glass electrode: advantages, challenges and similarities
14. Influence of oxygen content on the structural and sensing characteristics of Y2O3 sensing membrane for pH-ISFET10.1016/j.snb.2007.06.006 ↗
15. GaN-based diodes and transistors for chemical, gas, biological and pressure sensing
16. Stack of nano-films on optical fiber end-face for label-free bio-recognition10.1109/JLT.2016.2615294 ↗
17. Graphene-based devices for measuring pH10.1016/j.snb.2017.10.037 ↗
18. Scott · 1988 · 19
19. Interface traps in al/HfO2/SiO2/4H-SiC metal-insulator-semiconductor (MIS) structures studied by the thermally-stimulated current (TSC) technique10.1016/j.mee.2016.02.047 ↗
20. Creatinine sensitive biosensor based on ISFETs and creatinine deiminase immobilised in BSA membrane10.1016/S0039-9140(02)00283-7 ↗
21. A novel urea sensitive biosensor with extended dynamic range based on recombinant urease and ISFETs10.1016/S0956-5663(03)00175-1 ↗
22. Structure of 3-aminopropyl triethoxy silane on silicon oxide10.1016/0021-9797(91)90139-Y ↗
23. Enzyme field effect transistor (ENFET) for estimation of triglycerides using magnetic nanoparticles10.1016/j.bios.2008.02.003 ↗
24. Handheld measurement device for field-effect sensor structures: Practical evaluation and limitations10.1016/j.snb.2007.07.073 ↗
25. Study of the electrolyte-insulator-semiconductor field-effect transistor (EISFET) with applications in biosensor design10.1016/j.microrel.2006.10.003 ↗
26. Novel material concepts of transducers for chemical and biosensors10.1016/j.bios.2006.12.032 ↗