journal article·2021-04-27

Few-Layer MoS2Photodetector Arrays for Ultrasensitive On-Chip Enzymatic Colorimetric Analysis

Younggeun Park, Byunghoon Ryu, Seung Jun Ki, Brendan McCracken, Amanda Pennington, Kevin R. Ward, Xiaogan Liang, Katsuo Kurabayashi

ACS Nano· Volume 15· Issue 4
Publisher page

Abstract

Enzymatic colorimetric analysis of metabolites provides signatures of energy conversion and biosynthesis associated with disease onsets and progressions. Miniaturized photodetectors based on emerging two-dimensional transition metal dichalcogenides (TMDCs) promise to advance point-of-care diagnosis employing highly sensitive enzymatic colorimetric detection. Reducing diagnosis costs requires a batched multisample assay. The construction of few-layer TMDC photodetector arrays with consistent performance is imperative to realize optical signal detection for a miniature batched multisample enzymatic colorimetric assay. However, few studies have promoted an optical reader with TMDC photodetector arrays for on-chip operation. Here, we constructed 4 × 4 pixel arrays of miniaturized molybdenum disulfide (MoS2) photodetectors and integrated them with microfluidic enzyme reaction chambers to create an optoelectronic biosensor chip device. The fabricated device allowed us to achieve arrayed on-chip enzymatic colorimetric detection of d-lactate, a blood biomarker signifying the bacterial translocation from the intestine, with a limit of detection that is 1000-fold smaller than the clinical baseline, a 10 min assay time, high selectivity, and reasonably small variability across the entire arrays. The enzyme (Ez)/MoS2 optoelectronic biosensor unit consistently detected d-lactate in clinically important biofluids, such as saliva, urine, plasma, and serum of swine and humans with a wide detection range (10–3–103 μg/mL). Furthermore, the biosensor enabled us to show that high serum d-lactate levels are associated with the symptoms of systemic infection and inflammation. The lensless, optical waveguide-free device architecture should readily facilitate development of a monolithically integrated hand-held module for timely, cost-effective diagnosis of metabolic disorders in near-patient settings.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advanced biosensing and bioanalysis techniques · Nanoplatforms for cancer theranostics · Biosensors and Analytical Detection

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States

Michigan Center for Integrative Research in Critical Care, University of Michigan, Ann Arbor, Michigan 48109, United States

Department of Emergency Medicine, University of Michigan Medical School, Ann Arbor, Michigan 48109, United States

Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States

Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan 48109, United States

Funding

University of Michigan · Division of Electrical, Communications and Cyber Systems · Division of Chemical, Bioengineering, Environmental, and Transport Systems

References (54)

Show source-provided references
1. 10.1007/s00204-010-0609-610.1007/s00204-010-0609-6 ↗
2. 10.1007/s11306-018-1376-210.1007/s11306-018-1376-2 ↗
3. 10.1007/s00216-015-8700-810.1007/s00216-015-8700-8 ↗
4. 10.1007/s11306-016-1116-410.1007/s11306-016-1116-4 ↗
5. 10.1016/j.lungcan.2016.02.00610.1016/j.lungcan.2016.02.006 ↗
6. 10.1136/jclinpath-2018-20541410.1136/jclinpath-2018-205414 ↗
7. 10.1007/s00467-017-3844-810.1007/s00467-017-3844-8 ↗
8. 10.5049/EBP.2006.4.1.5310.5049/EBP.2006.4.1.53 ↗
9. 10.1097/01.ccx.0000235208.77450.1510.1097/01.ccx.0000235208.77450.15 ↗
10. 10.1186/2110-5820-3-310.1186/2110-5820-3-3 ↗
11. 10.1016/j.jss.2014.10.05710.1016/j.jss.2014.10.057 ↗
12. 10.1093/jn/135.7.161910.1093/jn/135.7.1619 ↗
13. 10.5812/ijp.440310.5812/ijp.4403 ↗
14. 10.1515/CCLM.2006.05410.1515/CCLM.2006.054 ↗
15. 10.1113/jphysiol.2003.05870110.1113/jphysiol.2003.058701 ↗
16. 10.1158/0008-5472.CAN-05-326010.1158/0008-5472.CAN-05-3260 ↗
17. 10.1016/j.clinbiochem.2008.06.01110.1016/j.clinbiochem.2008.06.011 ↗
18. Favre E. · Biotechnol. Techniques · 1990 · 4 · 31510.1007/BF00157428 ↗
19. 10.1021/ac00069a02210.1021/ac00069a022 ↗
20. 10.1016/j.crad.2008.07.00210.1016/j.crad.2008.07.002 ↗
21. 10.3168/jds.S0022-0302(40)95581-310.3168/jds.S0022-0302(40)95581-3 ↗
22. 10.1016/j.bios.2004.10.02910.1016/j.bios.2004.10.029 ↗
23. 10.1016/j.chroma.2005.01.07910.1016/j.chroma.2005.01.079 ↗
24. 10.2114/jpa.21.14310.2114/jpa.21.143 ↗
25. 10.1021/acsnano.5b0192910.1021/acsnano.5b01929 ↗
26. 10.1021/ac070410710.1021/ac0704107 ↗
27. 10.1038/srep3275510.1038/srep32755 ↗
28. 10.1038/nnano.2012.18610.1038/nnano.2012.186 ↗
29. 10.1038/nprot.2013.08510.1038/nprot.2013.085 ↗
30. 10.1038/nnano.2013.3010.1038/nnano.2013.30 ↗
31. 10.1021/nn202852j10.1021/nn202852j ↗
32. 10.1038/nnano.2010.27910.1038/nnano.2010.279 ↗
33. 10.1021/nn305301b10.1021/nn305301b ↗
34. 10.1103/PhysRevLett.108.19680210.1103/PhysRevLett.108.196802 ↗
35. 10.1038/nnano.2013.10010.1038/nnano.2013.100 ↗
36. 10.1021/acsnano.7b0116210.1021/acsnano.7b01162 ↗
37. 10.1002/smll.20190561110.1002/smll.201905611 ↗
38. 10.1021/acssensors.6b0079510.1021/acssensors.6b00795 ↗
39. 10.1021/acsnano.8b0237110.1021/acsnano.8b02371 ↗
40. 10.1021/nn501342910.1021/nn5013429 ↗
41. 10.1038/nchem.158910.1038/nchem.1589 ↗
42. 10.1002/adma.20110479810.1002/adma.201104798 ↗
43. 10.1002/adfm.20110211110.1002/adfm.201102111 ↗
44. 10.1063/1.482420510.1063/1.4824205 ↗
45. 10.1103/PhysRevB.89.12540610.1103/PhysRevB.89.125406 ↗
46. 10.1088/1367-2630/16/11/11305510.1088/1367-2630/16/11/113055 ↗
47. 10.1021/acsnano.8b0375410.1021/acsnano.8b03754 ↗
48. 10.1063/1.512861310.1063/1.5128613 ↗
49. 10.1063/1.36695010.1063/1.366950 ↗
50. 10.1021/acsami.8b2162910.1021/acsami.8b21629 ↗
51. 10.1109/LED.2015.241253610.1109/LED.2015.2412536 ↗
52. 10.1088/0957-4484/27/16/16520310.1088/0957-4484/27/16/165203 ↗
53. 10.1016/j.talanta.2019.04.05410.1016/j.talanta.2019.04.054 ↗
54. 10.1038/lsa.2014.310.1038/lsa.2014.3 ↗