Clean water photovoltaic sensor for solar disinfection in developing countries
Source abstract
Abstract
One of the limitations for the widespread use of solar water disinfection Technologies in developing regions is the lack of low-cost clean water sensors. A new type of low-cost sensors using photovoltaic solar cells that provide information about received irradiance, temperature, UV irradiance and sunshine duration is presented. A key aspecto of the design is the UV irradiance measurement. Two identical cells are used, one of them with a low-cost UV-blocking filter on top, so the total UV irradiance can be calculated as the difference between the two solar cells out puts. The first cell would be measuring UV–vis–NIR and the second Orly vis–NIR. TheUV filter material was explored and a low-cost architectural film was selected. Materials costs for the first prototype were of approximately 4€ excluding labour. Initial testing also included experiments with real polluted water and Escherichia coli, showing the feasibility of the new design.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Water Quality Monitoring Technologies · Solar-Powered Water Purification Methods · Water-Energy-Food Nexus Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (46)
Show source-provided references
1. Solar water disinfection (SODIS): a review from bench-top to roof-top10.1016/j.jhazmat.2012.07.053 ↗
2. 2011
3. 〈http:/www.meteonorm.com〉, 2013 (last accessed 22 May).
4. Bactericidal effect of solar water disinfection under real sunlight conditions10.1128/AEM.02415-07 ↗
5. G.J. McGeorge, P. De Vries. Method and Apparatus for verifying ultraviolet sterilization, US Patent 8292100, 2001.
6. D.M. Brown, K. Matocha, P.M. Sandvik, L. Lombardo, Ultraviolet sensors for monitoring energy in the germicidal wavelengths, US Patent Application Number 2004/0200975, 2004.
7. G.P. Smestad, Ultraviolet light detector for liquid disinfection unit, US Patent 6429438, 2002.
8. A camera phone-based UV-dosimeter for monitoring the solar disinfection (SODIS) of water10.1109/JSEN.2011.2172938 ↗
9. Application of azo dyes as dosimetric indicators for enhanced photocatalytic solar disinfection (ENPHOSODIS)10.1016/j.jphotochem.2010.12.016 ↗
10. Photocatalytic enhancement for solar disinfection of water: a review10.1155/2011/798051 ↗
11. K. Goudjil, Photochromic ultraviolet detector, US Patent 5581090, 1996.
12. R. Lantis, J.P. Phelan, A. Phelan, Method and apparatus for solar-based water disinfection, US Patent 8292100, 2012.
13. J.M. Questel, C.D. Sololowski, Sunlight dosage indicator, US Patent 6734440, 2004.
14. S.A. Jackson, J.R. Mercer, E. Atrazheva, K. Hudda S. Wang, Radiation indicator device, US Patent 6504161, 2003.
15. B. Ferren, W.D. Willis, Ultraviolet radiation exposure sensor, US Patent 6818904, 2004.
16. Helioz GmbH, 〈http:/www.helioz.org〉 (last accessed 08.07.201.
17. M. Wesian, Device and method for determining the degree of disinfection of a liquid, US Patent Application Number 2012/0318997.
18. Metcalf · 2006
19. International Standard IEC 60904—Part 2: ‘Requirements for Reference Solar Cells’, UNE-EN, international standard, 1989.
20. International Standard IEC 60904-5: ‘Photovoltaic Devices. Part 5. Determination of the Equivalent Cell Temperature (ECT) of Photovoltaic (PV) Devices by the Open-Circuit Voltage Method’, UNE-EN, international standard, 1989.
21. Pyranometers and reference cells, what's the difference?
22. H. Haeberlin, et al., Comparison of pyranometer and si-reference cell solar irradiation data in long term PV plant monitoring, in: Proceedings of the 13th EU PV Conference on Photovoltaic Energy Conversion, Nice, France, 1995.
23. L. Dunn, M. Gostein, K. Emery, Comparison of pyranometers vs. reference cells for evaluation of PV array performance, in: Proceedings of the 38th IEEE Photovoltaic Specialists Conference (PVSC), Austin, TX, June 3–8, 2012.10.1109/PVSC.2012.6318193 ↗
24. Pyranometers and reference cells, what makes the most sense for pv power plants?
25. ESTI-LOG PV plant monitoring system10.1016/S0927-0248(97)00051-2 ↗
26. M. Vivar et al., Estimation of sunshine duration from the global irradiance measured by a photovoltaic silicon solar cell Renewable and Sustainable Energy Reviews, (submitted for publication).
27. Measurement of Sunshine Duration. Part I: Measurement of Meteorological Variables’, World Meteorological Organisation (WMO), Guide to Meteorological Instruments and Methods of Observation, 8th ed, Secretariat of the World Meteorological Organisation, 2008, Update 2010.
28. Comparison of pyranometric and pyrheliometric methods for the determination of sunshine duration10.1175/JTECH2013.1 ↗
29. Y.B.L. Hinssen, Comparison of Different Methods for the Determination of Sunshine Duration, KNMI Scientific Rep WR‐2006‐06, 72 pp.
30. E. Vuerich et al., Updating and Development of Methods for Worldwide Accurate Measurements of Sunshine Duration’, TECO‐2012, Brussels, Belgium, 16–18 October 2012.
31. Vivar · 2013
32. 2012
33. SCL SR PS4 Llumar film technical datasheet, provided by Impersol Lda 〈www.impersol.pt〉, 2013.
34. SCL SR PS4 Llumar film reference installation guide, provided by Impersol Lda, 2013.
35. International Standard IEC 61215: Crystalline Silicon Terrestrial Photovoltaic (PV) Modules. Design Qualification and Approval.
36. SODIS—an emerging water treatment process
37. Bactericidal effect of solar water disinfection under real sunlight conditions10.1128/AEM.02415-07 ↗
38. Disinfection of drinking water contaminated with cryptosporidium parvum oocysts under natural sunlight and using the photocatalyst TiO210.1016/j.jphotobiol.2007.05.004 ↗
39. Effect of the radiation intensity, water turbidity and exposure time on the survival of cryptosporidium during simulated solar disinfection of drinking water10.1016/j.actatropica.2009.06.004 ↗
40. Efficiency of PET reactors in solar water disinfection for use in Southeastern Brazil10.1016/j.solener.2012.10.016 ↗
41. Solar water disinfection: scope of the process and analysis of radiation experiments
42. Efficacy of solar disinfection of Escherichia coli, Shigella flexneri, Salmonella typhimurium and Vibrio cholerae10.1111/j.1365-2672.2006.02983.x ↗
43. ‘Solar Water Disinfection—A Guide for the Application of SODIS’, SANDEC, Eawag, Duebendorf, 2002, SANDEC Report No 06/ 02, ISBN: 3-906484-24-6
44. Acra · 1984
45. ISO 9308-1:2000, Water Quality – Detection and Enumeration of Escherichia coli and Coliform bacteria—Part 1: Membrane filtration method, Spanish standard, 2000.
46. M. Fuentes, et al., Design of a real low cost portable datalogger for renewable energy applications using arduino. case of photovoltaic systems, Energy, (submitted for publication)