Studying the outdoor performance of organic building-integrated photovoltaics laminated to the cladding of a building prototype
Source abstract
Abstract
Abstract The outdoor dependence of module orientation and diurnal climatic conditions on the performance of Organic Photovoltaics (OPVs) configured for Building Integrated PV (BIPV) arrays is reported. The study focuses upon a Northern European climate and the significance of module orientation upon energy yield across diurnal, seasonal change and climatic conditions are discussed. It is shown that the optimum position of a BIPV facade depends upon season and that a south facing BIPV facade provides the greatest energy yield during winter months. The results also show how west-facing modules can significantly contribute to power generation during peak power periods (5–8 p.m.), which is imperative for balancing energy demand for buildings of the future and in particular supply the energy needs of buildings during peak hours in Northern Europe. Electrical characteristics under standard and part-load conditions were collated from laboratory scale OPV module experimental data and scaled for commercial-size modules in order to simulate BIPV arrays based upon OPVs. The simulated data is compared to experimental data and the closeness shows that BIPV systems based upon OPVs can be accurately simulated prior to installation. The system simulations compare typical energy demand profiles of small commercial buildings and illustrate that OPV arrays show strong potential to be used with excess energy generation for 8 months of the year based upon a 4.22kWp OPV system. Four 4.22kWp OPV systems scenarios have been investigated for (1) the highest annual energy generation, (2) architecturally evenly-spaced around the building (avoiding a North facade), (3) grid-balancing and (4) East-West split. Whilst Scenario 4 shows the lowest overall energy yield over the course of the year, energy production during peak hours is substantially higher than in other scenarios. The options presented show that OPVs are viable to use in BIPVs and can adequately meet the energy demand of a small commercial building during spring, summer and autumn in Norther Europe and can be adapted to end user's needs.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Organic Electronics and Photovoltaics · Advanced battery technologies research · Conducting polymers and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. 25th anniversary article: a decade of organic/polymeric photovoltaic research10.1002/adma.201302563 ↗
2. A polymer tandem solar cell with 10.6% power conversion efficiency10.1038/ncomms2411 ↗
3. Polymer homo-tandem solar cells with best efficiency of 11.3%10.1002/adma.201404220 ↗
4. Outdoor performance of organic photovoltaics: diurnal analysis, dependence on temperature, irradiance, and degradation10.1063/1.4906915 ↗
5. Three dimensional corrugated organic photovoltaics for building integration; improving the efficiency, oblique angle and diffuse performance of solar cells10.1039/C5EE02162F ↗
6. The future of organic photovoltaic solar cells as a direct power source for consumer electronics10.1016/j.solmat.2012.04.001 ↗
7. Building integrated photovoltaics (BIPV): review, potentials, barriers and myths10.1515/green-2013-0020 ↗
8. Solar trees: first large-scale demonstration of fully solution coated, semitransparent, flexible organic photovoltaic modules
9. The case for organic photovoltaics10.1039/c3ra42989j ↗
10. Over 2 years of outdoor operational and storage stability of ITO-free, fully roll-to-roll fabricated polymer solar cell modules10.1002/ente.201500086 ↗
11. Flexible organic P3HT:PCBM bulk-heterojunction modules with more than 1 year outdoor lifetime10.1016/j.solmat.2008.01.004 ↗
12. High density plasma enhanced chemical vapor deposition of optical thin films10.1051/epjap:2004206 ↗
13. Consensus stability testing protocols for organic photovoltaic materials and devices10.1016/j.solmat.2011.01.036 ↗
14. European Union, L 140 · Off. J. Eur. Union · 2009 · 52 · 20
15. Flexible solar cells for clothing10.1016/S1369-7021(06)71542-5 ↗
16. Assessing the potential of steel as a substrate for building integrated photovoltaic applications10.1016/j.apenergy.2018.07.119 ↗
17. Heliatek, The world’s largest BiOPV installation completed in France using Heliatek’s Solar Film Solution, HeliaSol ® pp. 5–7. 〈http://www.heliatek.com/de/presse/pressemitteilungen/details/weltweit-groesste-biopv-installation-mit-heliateks-solarfolienloesung-heliasol-in-frankreich〉.
18. BELECTRIC, The world’s first grid-connected OPV system has been running reliably since 2012 3–6, 2016.
19. Semi-transparent organic inverted photovoltaic cells with solution processed top electrode10.1016/j.solmat.2012.09.002 ↗
20. Semi-transparent polymer solar cells with 6% PCE, 25% average visible transmittance and a color rendering index close to 100 for power generating window applications10.1039/c2ee22623e ↗
21. Transparent, near-infrared organic photovoltaic solar cells for window and energy-scavenging applications10.1063/1.3567516 ↗
22. Spray coated silver nanowires as transparent electrodes in OPVs for Building Integrated Photovoltaics applications10.1016/j.solmat.2016.05.053 ↗
23. Large area ITO-free organic solar cells on steel substrate, Org. Electron. Physics
24. Selection of metal substrates for completely solution-processed inverted organic photovoltaic devices10.1016/j.solmat.2013.02.010 ↗
25. Electrical-thermal-mechanical properties of multifunctional OPV-ETFE foils for large-span transparent membrane buildings10.1016/j.polymertesting.2018.01.036 ↗
26. A multifunctional ETFE module for sustainable façade lighting: design, manufacturing and monitoring10.1016/j.enbuild.2017.12.023 ↗
27. Printable luminescent down shifter for enhancing efficiency and stability of organic photovoltaics10.1016/j.solmat.2015.09.037 ↗
28. ITO-free laminated concept for flexible organic solar cells10.1016/j.solmat.2013.09.024 ↗
29. East to west - The optimal tilt angle and orientation of photovoltaic panels from an electricity system perspective10.1016/j.apenergy.2015.08.097 ↗
30. M. Mehrtash, G. Quesada, Y. Dutil, D. Rousse, Performance Evaluation of Sun Tracking Photovoltaic Systems in Canada, in; Proceedings of the 20th Annu. International Confernece Mech. Eng pp. 18–21. 〈http://www.t3e.info/pdf/Publications/2012-ISME〉- Performance Evaluation of Sun Tracking Photovoltaic Systems in Canada.pdf.