journal article·2026-01-09Open access

Strategies for Enhancing the Stability of High-Electric-Field Perovskite Single-Crystal Radiation Detectors

Wenqing Zhang, Hu Wang, Jie Fu, Pengxiang Wang, Hao Dong, Zijun Gao, Yuchuan Shao

ACS Energy Letters· Volume 11· Issue 1

Abstract

High Resolution Image Download MS PowerPoint Slide While a high electric field enhances the sensitivity and response speed of MAPbBr 3 single-crystal radiation detectors, it also triggers interfacial electrochemical corrosion and ion migration, compromising device stability. This study reveals that multivalent titanium ion (Ti 4+ ) migration in MAPbBr 3 single-crystal radiation detectors at a high electric field requires grain boundary (GBs) assistance and is confined to the polycrystalline regions, located hundreds of nanometers from the crystal surface. Consequently, device performance can be fully restored by removing the corroded surface and redepositing the electrode. Furthermore, our results also illustrate that humidity and oxygen in the atmosphere can accelerate the electrochemical reaction at the Ti/perovskite single-crystal interface, highlighting the importance of encapsulation for perovskite single-crystal-based devices.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Perovskite Materials and Applications · Radioactive contamination and transfer · Nuclear materials and radiation effects

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Laboratory of Thin Film Optics

Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences

Center of Materials Science and Optoelectronics Engineering

University of Chinese Academy of Sciences

Key Laboratory of Materials for High Power Laser

Chinese Academy of Sciences

School of Microelectronics

Shanghai University

Hangzhou Institute for Advanced Study

Funding

Youth Innovation Promotion Association of the Chinese Academy of Sciences · Shanghai Explorer Program

References (20)

Show source-provided references
1. 10.1038/s41566-024-01506-y10.1038/s41566-024-01506-y ↗
2. 10.1002/lpor.20240047010.1002/lpor.202400470 ↗
3. 10.1021/acsenergylett.0c0180510.1021/acsenergylett.0c01805 ↗
4. 10.1126/sciadv.abd158010.1126/sciadv.abd1580 ↗
5. 10.1002/adfm.20220343210.1002/adfm.202203432 ↗
6. 10.1021/acs.accounts.5b0042010.1021/acs.accounts.5b00420 ↗
7. 10.1039/C9TA12032G10.1039/C9TA12032G ↗
8. 10.1002/adfm.20200199510.1002/adfm.202001995 ↗
9. 10.1021/acsenergylett.4c0203310.1021/acsenergylett.4c02033 ↗
10. 10.1002/adma.20230220610.1002/adma.202302206 ↗
11. 10.1002/advs.20170066210.1002/advs.201700662 ↗
12. 10.1063/1.513091410.1063/1.5130914 ↗
13. 10.1039/C6EE00413J10.1039/C6EE00413J ↗
14. 10.1021/acsami.3c1811610.1021/acsami.3c18116 ↗
15. 10.1021/acsaem.8b0091310.1021/acsaem.8b00913 ↗
16. 10.1021/acsenergylett.6b0032010.1021/acsenergylett.6b00320 ↗
17. 10.1039/C5CP07577G10.1039/C5CP07577G ↗
18. 10.1038/nmat492710.1038/nmat4927 ↗
19. NIST. X-ray Mass Attenuation Coefficients – Table 3 http://physics.nist.gov/PhysRefData/XrayMassCoef/tab3.html (accessed: 2025–07–03).
20. 10.1038/ncomms858610.1038/ncomms8586 ↗