Morphology and Dissolution Rate of Wear Debris from Silicon Nitride Coatings
Source abstract
Abstract
Silicon nitride (SiNx) coatings have recently been introduced as a potential material for joint implant bearing surfaces, but there is no data on wear debris morphology nor their dissolution rate, something that could play a central role to implant longevity. In this study, wear debris was generated in a ball-on-disc setup in simulated body fluid. After serum digestion the debris was analyzed with scanning electron microscopy and energy-dispersive X-ray spectroscopy. The particle dissolution rate was evaluated using inductively coupled plasma techniques, on model SiNx particles. The wear debris from SiNx coatings was found to be round, in the nm range and formed agglomerates in the submicrometer to micrometer range. Model particles dissolved in simulated body fluid at a rate of: c(t) = 39.45[1 – exp(−1.11 × 10–6t)], where [c(t)] = mg/L and [t] = s. This study can be used as a preliminary prediction of size, shape, and dissolution rate of wear debris from SiNx coatings.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Metal and Thin Film Mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Materials in Medicine Group, Division of Applied Materials Science, Department of Engineering Sciences, Uppsala University, Lägerhyddsvägen 1, 752 37 Uppsala, Sweden
Funding
Seventh Framework Programme
References (47)
Show source-provided references
1. 10.1243/095441100153521910.1243/0954411001535219 ↗
2. 10.1243/095441197153463810.1243/0954411971534638 ↗
3. 10.1023/A:100890130264610.1023/A:1008901302646 ↗
4. 10.1002/jbm.1030210.1002/jbm.10302 ↗
5. 10.1302/0301-620X.90B8.2073710.1302/0301-620X.90B8.20737 ↗
6. 10.1016/j.biomaterials.2004.04.03510.1016/j.biomaterials.2004.04.035 ↗
7. Swedish Hip Arthroplasty Register Annual Report 2013;Swedish Hip Arthroplasty Register:Gothenburg, Sweden, 2013.
8. The New Zealand Joint Registry Annual Report 2014;New Zealand Orthopaedic Association:Wellington, NZ, 2014.
9. Australian Orthopaedic Association’s National Joint Replacement Registry Annual Report 2014;Australian Orthopaedic Association:Sydney, Australia, 2014.
10. 10.1243/09544119JEIM9910.1243/09544119JEIM99 ↗
11. 10.1002/jbm.b.3290210.1002/jbm.b.32902 ↗
12. 10.1002/(SICI)1097-4636(199810)42:1<103::AID-JBM13>3.3.CO;2-D10.1002/(SICI)1097-4636(199810)42:1<103::AID-JBM13>3.3.CO;2-D ↗
13. 10.1243/09544119JEIM11210.1243/09544119JEIM112 ↗
14. Billi F. · J. Appl. Biomater. Biomech. · 2010 · 8 · 1
15. 10.1002/jat.272910.1002/jat.2729 ↗
16. 10.1016/S0142-9612(02)00047-910.1016/S0142-9612(02)00047-9 ↗
17. 10.3109/1745367090287673010.3109/17453670902876730 ↗
18. 10.2106/JBJS.G.0013010.2106/JBJS.G.00130 ↗
19. 10.1007/s11999-014-3725-410.1007/s11999-014-3725-4 ↗
20. 10.3109/15563650.2014.94497710.3109/15563650.2014.944977 ↗
21. 10.1023/B:JMSM.0000015482.24542.7610.1023/B:JMSM.0000015482.24542.76 ↗
22. 10.1007/s10856-012-4625-310.1007/s10856-012-4625-3 ↗
23. 10.1016/j.jmbbm.2013.05.00210.1016/j.jmbbm.2013.05.002 ↗
24. 10.1016/j.msec.2016.01.04910.1016/j.msec.2016.01.049 ↗
25. Pettersson, M.; Oladokun, A.; Bryant, M.; Engqvist, H.; Hall, R.; Persson, C.; Neville, A. (2016) Fretting Behaviour of Silicon Nitride against Biomedical Alloys for Joint Replacements; Submitted toJournal of Biomedical Materials Research: Part B - Applied Biomaterials.10.1016/j.msec.2016.01.049 ↗
26. 10.1179/1751584X15Y.000000001410.1179/1751584X15Y.0000000014 ↗
27. 10.4161/biom.2071010.4161/biom.20710 ↗
28. 10.1016/j.actbio.2012.04.03110.1016/j.actbio.2012.04.031 ↗
29. 10.1016/j.surfcoat.2013.09.00810.1016/j.surfcoat.2013.09.008 ↗
30. Pettersson M. · 2015
31. 10.1016/j.actbio.2013.08.03910.1016/j.actbio.2013.08.039 ↗
32. 10.1006/jcis.1999.642510.1006/jcis.1999.6425 ↗
33. 10.1111/j.1151-2916.2000.tb01567.x10.1111/j.1151-2916.2000.tb01567.x ↗
34. 10.1111/jace.1250910.1111/jace.12509 ↗
35. 10.1016/j.jmbbm.2013.05.00210.1016/j.jmbbm.2013.05.002 ↗
36. 10.1016/j.jbiomech.2006.12.00510.1016/j.jbiomech.2006.12.005 ↗
37. 10.1016/j.ultramic.2010.10.01110.1016/j.ultramic.2010.10.011 ↗
38. 10.1016/j.nano.2011.04.00510.1016/j.nano.2011.04.005 ↗
39. 10.1002/jbm.a.3195210.1002/jbm.a.31952 ↗
40. 10.1016/S0043-1648(99)00243-410.1016/S0043-1648(99)00243-4 ↗
41. 10.1243/09544110376521265910.1243/095441103765212659 ↗
42. 10.1016/j.biomaterials.2003.10.09010.1016/j.biomaterials.2003.10.090 ↗
43. 10.1002/(SICI)1097-4644(19980101)68:1<83::AID-JCB8>3.0.CO;2-S10.1002/(SICI)1097-4644(19980101)68:1<83::AID-JCB8>3.0.CO;2-S ↗
44. 10.1016/j.wear.2005.02.10410.1016/j.wear.2005.02.104 ↗
45. 10.1116/1.161597410.1116/1.1615974 ↗
46. 10.1148/radiology.208.1.964679110.1148/radiology.208.1.9646791 ↗
47. 10.1515/CCLM.2001.19610.1515/CCLM.2001.196 ↗