Abstract

The human metabolic rate has attracted increasing interest as it is the most critical parameter in thermal comfort evaluation, a challenging field, while it is always determined imprecisely. The main issue hampering metabolic rate portable measurement is a lack of reliable methods. Current measuring solutions are unsatisfactory because nonportable bulky size systems and disturbance masks are required. This paper proposes a novel metabolic rate measurement model, which we believe is the first of its kind, to accurately identify and predict human metabolism values via wearable technology. Based on a newly developed theory, the designed wearable metabolic rate sensor was fabricated to measure key parameters: heart rate, heat loss, and skin resistance. Together with the body muscle rate, the new final linear metabolic rate model showed easy prediction capability. Eight volunteers were invited for the experiment under three conditions under four activity intensity states. First, the results significantly verify that a linear relationship exists between the metabolic rate tested by the Quark CPET instrument and our proposed model, with a high coefficient of determination ( R 2 ≈ 0.90). The correlation model is worth mentioning because it coincides with our hypothesis, with at least 95% overall accuracy and less than 2% uncertainty under each condition. Second, the most remarkable finding is that our model is exceedingly suitable ( R 2 ≈ 0.90) for the same person, regardless of the experimental temperature. Finally, validation is conducted in a wider metabolic range, further strengthening confidence in our metabolic rate estimation approach. In summary, based on an innovative methodology, our novel metabolic rate sensor is wearable, comfortable, real-time achievable, and miniaturized compared with the existing equipment. This paper sheds new light on human metabolic rate measurement and prediction. Furthermore, our approach and designed sensor can be applied to evaluate indoor thermal comfort precisely, thus leading to reduced energy consumption.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Thermoregulation and physiological responses · Building Energy and Comfort Optimization · Advanced Sensor and Energy Harvesting Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, China

Thrust of Sustainable Energy and Environment, The Hong Kong University of Science and Technology (Guangzhou), Guangzhou 511400, China

Funding

Innovation and Technology Fund

References (48)

Show source-provided references
1. International Standardization Organization. Moderate Thermal Environments─Determination of the PMV and PPD Indices and Specifications for Thermal Comfort; ISO: 7730, Geneva, Switzerland, 2005.
2. 10.1016/j.buildenv.2016.06.00110.1016/j.buildenv.2016.06.001 ↗
3. 10.1016/j.buildenv.2009.06.02210.1016/j.buildenv.2009.06.022 ↗
4. 10.1080/17508975.2015.101107110.1080/17508975.2015.1011071 ↗
5. 10.3390/su1201017010.3390/su12010170 ↗
6. 10.1016/j.buildenv.2006.05.01210.1016/j.buildenv.2006.05.012 ↗
7. 10.1016/j.buildenv.2016.10.00710.1016/j.buildenv.2016.10.007 ↗
8. 10.1016/j.enbuild.2014.02.06710.1016/j.enbuild.2014.02.067 ↗
9. 10.1093/ajcn/82.5.94110.1093/ajcn/82.5.941 ↗
10. 10.1016/j.enbuild.2016.02.04110.1016/j.enbuild.2016.02.041 ↗
11. 10.1016/j.buildenv.2020.10730210.1016/j.buildenv.2020.107302 ↗
12. McArdle W. D. · 2014
13. 10.1053/jada.2003.5011610.1053/jada.2003.50116 ↗
14. 10.1177/014860711452761910.1177/0148607114527619 ↗
15. 10.1016/S1440-2440(04)80039-210.1016/S1440-2440(04)80039-2 ↗
16. 10.3389/fphys.2018.0176410.3389/fphys.2018.01764 ↗
17. 10.7600/jpfsm.2.9310.7600/jpfsm.2.93 ↗
18. 10.1007/s00421-017-3735-510.1007/s00421-017-3735-5 ↗
19. 10.1016/j.apenergy.2013.04.01410.1016/j.apenergy.2013.04.014 ↗
20. 10.1016/j.buildenv.2016.04.00810.1016/j.buildenv.2016.04.008 ↗
21. International Standardization Organization. Ergonomics of the Thermal Environment-Determination of Metabolic Rate; ISO: 8996, Geneva, Switzerland, 2004.
22. 10.2486/INDHEALTH.2016-017710.2486/INDHEALTH.2016-0177 ↗
23. 10.1016/j.buildenv.2019.10621610.1016/j.buildenv.2019.106216 ↗
24. Stivoric, J.; Pacione, C.; Teller, E.; Andre, D.; Kasabach, C.; Boehmke, S.; Vishnubhatla, S.; Safier, S.; Farringdon, J.; Pelletier, R. Device to Enable Quick Entry of Caloric Content, June 14, 2011.
25. 10.1609/aimag.v33i2.240810.1609/aimag.v33i2.2408 ↗
26. 10.1038/s41598-018-19239-810.1038/s41598-018-19239-8 ↗
27. 10.1021/acsbiomaterials.1c0069910.1021/acsbiomaterials.1c00699 ↗
28. 10.1021/acsbiomaterials.1c0080010.1021/acsbiomaterials.1c00800 ↗
29. 10.1021/acssensors.2c0082410.1021/acssensors.2c00824 ↗
30. 10.1002/admt.20190115510.1002/admt.201901155 ↗
31. Yang, J.; Qiu, H. Multimodal Sensing for Thermal Comfort and Energy Saving in Smart Buildings; CLP Research Institute: HK, China, 2016; pp 1–5.
32. 10.1016/S0378-7788(02)00004-X10.1016/S0378-7788(02)00004-X ↗
33. 10.1093/ajcn/54.1.175b10.1093/ajcn/54.1.175b ↗
34. 10.1016/j.buildenv.2012.07.00310.1016/j.buildenv.2012.07.003 ↗
35. Anonymous · 2002
36. 10.1016/j.jtherbio.2013.09.00310.1016/j.jtherbio.2013.09.003 ↗
37. 10.3389/fneur.2018.0102910.3389/fneur.2018.01029 ↗
38. 10.1172/JCI11485710.1172/JCI114857 ↗
39. Vaughn, C. The effect of skeletal muscle mass on basal metabolic rate in college-age males. Master’s Thesis, Cortland University, Cortland, 2013, pp 1–60.
40. 10.1093/gerona/glaa07110.1093/gerona/glaa071 ↗
41. 10.1016/j.cmet.2011.06.01210.1016/j.cmet.2011.06.012 ↗
42. 10.1210/jendso/bvac15110.1210/jendso/bvac151 ↗
43. 10.1016/j.apenergy.2019.04.06510.1016/j.apenergy.2019.04.065 ↗
44. Braian M, B.; Camila, C.; Antonella De, V.; Carlos G, M. Human Physiology in Extreme Heat and Cold. https://clinmedjournals.org/, 2018; Vol. 1.10.23937/iacph-2017/1710001 ↗
45. Marriott B. M. · 1993
46. 10.1016/j.buildenv.2022.10885210.1016/j.buildenv.2022.108852 ↗
47. Liden, C. B.; Wolowicz, M.; Stivoric, J. M.; Teller, A.; Vishnubhatla, S.; Farringdon, J. Accuracy and Reliability of the SenseWearTM Armband as an Energy Expenditure Assessment Device, 2002;
48. 10.21037/atm.2017.02.3110.21037/atm.2017.02.31 ↗