Design concepts for the tallest free‐standing fiberglass stack
Source abstract
Abstract
Abstract This paper presents design and materials considerations involved in the production of large, free standing glass reinforced plastic (GRP) industrial stacks. Because of large wind loads, such stacks must be designed with sophisticated structural analysis techniques, especially at load transfer points. This paper details such considerations for the world's tallest GRP stack.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Structural Analysis of Composite Materials · Structural Analysis and Optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (3)
Show source-provided references
1. Proceedings of the 1975 International Conference on Composite Materials Geneva Switzerland and Boston Mass. April 7–18 1975 Vols. 1 and 2.
2. Specification for Fiberglass Reinforced Plastic Structural Fume Stacks American Society for Testing Materials Committee D‐20 1978.
3. Composite Materials: Testing and Design American Society for Testing Materials ASTMSTP 546 Philadelphia Pa. 1974.