Deep Level Transient Spectroscopic Analysis on Au/SiO2/InP MOS Structures
Source abstract
Abstract
Deep Level Transient Spectroscopy (DLTS) studies have been carried out on Au/SiO2/InP Metal–Oxide–Semiconductor (MOS) diodes. Majority and minority carrier traps have been observed for the room temperature SiO2 deposited samples. The effect of substrate temperature during SiO2 deposition has been analysed using DLTS. It has been observed that the minority carrier trap is removed while SiO2 deposition is carried out at an elevated temperature. The detected traps have been analysed under different reverse bias values to distinguish between the bulk and interface traps.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Semiconductor materials and devices · Semiconductor materials and interfaces · Silicon Nanostructures and Photoluminescence
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References
Reference metadata was not supplied for this record.