Metal–Organic Frameworks on Palladium Nanoparticle–Functionalized Carbon Nanotubes for Monitoring Hydrogen Storage
Source abstract
Abstract
Palladium is a well-known hydrogen-absorbing material. When palladium is functionalized with copper(II) benzene-1,3,5-tricarboxylate (HKUST-1), a hydrogen-adsorbing metal–organic framework, its hydrogen-absorption capacity can be increased. In this work, we show that, by growing the HKUST-1 on palladium nanoparticle-functionalized single-walled carbon nanotubes (Pd NP/SWCNT), we can dynamically monitor the adsorption and desorption of hydrogen from the HKUST-1 and Pd NP composite by using the carbon nanotubes as transducers in chemiresistors. Addition of HKUST-1 to the Pd NP/SWCNT was shown to increase the sensitivity of the nanocomposite material to hydrogen by 300% and limit of detection to hydrogen by 33%. The increase in sensitivity was attributed to the increased hydrogen sorption capacity of the combined HKUST-1/Pd NP. A factor of 8 improvement in sensitivity was further achieved by using semiconductor-enriched SWCNT instead of mixed metallic/semiconducting nanotubes and a corresponding improvement in the theoretical limit of detection down to 70 ppb.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Metal-Organic Frameworks: Synthesis and Applications · Covalent Organic Framework Applications · Hydrogen Storage and Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
Department of Chemical & Petroleum Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
Funding
Division of Chemistry
References (51)
Show source-provided references
1. 10.1126/science.111324710.1126/science.1113247 ↗
2. 10.1039/b802426j10.1039/b802426j ↗
3. 10.1002/anie.20210625910.1002/anie.202106259 ↗
4. 10.1038/nchem.83410.1038/nchem.834 ↗
5. 10.1021/cs400959k10.1021/cs400959k ↗
6. 10.1038/nmat411310.1038/nmat4113 ↗
7. 10.1021/cr200324t10.1021/cr200324t ↗
8. 10.1039/C9CS00778D10.1039/C9CS00778D ↗
9. 10.1021/la702466d10.1021/la702466d ↗
10. 10.1021/ja512311a10.1021/ja512311a ↗
11. 10.1038/nchem.33310.1038/nchem.333 ↗
12. 10.1002/1521-4095(200109)13:18<1384::AID-ADMA1384>3.0.CO;2-810.1002/1521-4095(200109)13:18<1384::AID-ADMA1384>3.0.CO;2-8 ↗
13. 10.1021/jp067716m10.1021/jp067716m ↗
14. 10.1021/nn101992g10.1021/nn101992g ↗
15. 10.1021/acssensors.8b0000610.1021/acssensors.8b00006 ↗
16. 10.1126/science.287.5459.180110.1126/science.287.5459.1801 ↗
17. 10.1126/science.287.5453.62210.1126/science.287.5453.622 ↗
18. 10.1021/ja038702m10.1021/ja038702m ↗
19. 10.1021/la046867i10.1021/la046867i ↗
20. 10.1021/jz301711a10.1021/jz301711a ↗
21. 10.1021/ja402887v10.1021/ja402887v ↗
22. 10.1021/acssensors.6b0080810.1021/acssensors.6b00808 ↗
23. 10.1038/ncomms1094210.1038/ncomms10942 ↗
24. 10.1021/acs.chemrev.8b0031110.1021/acs.chemrev.8b00311 ↗
25. 10.1002/anie.20141185410.1002/anie.201411854 ↗
26. 10.1021/jacs.9b1340210.1021/jacs.9b13402 ↗
27. 10.1021/acs.chemrev.9b0076610.1021/acs.chemrev.9b00766 ↗
28. 10.1039/C8SC03987A10.1039/C8SC03987A ↗
29. 10.1021/acsami.0c2150910.1021/acsami.0c21509 ↗
30. 10.1039/C4RA06792D10.1039/C4RA06792D ↗
31. 10.1021/jacs.1c0167310.1021/jacs.1c01673 ↗
32. 10.1021/acsnano.1c0640210.1021/acsnano.1c06402 ↗
33. 10.1021/acsnano.0c0901510.1021/acsnano.0c09015 ↗
34. 10.1016/j.ijhydene.2011.03.10910.1016/j.ijhydene.2011.03.109 ↗
35. 10.1021/acsomega.9b0033010.1021/acsomega.9b00330 ↗
36. 10.1016/j.apsusc.2011.11.07510.1016/j.apsusc.2011.11.075 ↗
37. 10.1021/acs.chemrev.5b0032410.1021/acs.chemrev.5b00324 ↗
38. 10.1002/adfm.20100252910.1002/adfm.201002529 ↗
39. 10.1021/ja050882810.1021/ja0508828 ↗
40. 10.1038/nmat403010.1038/nmat4030 ↗
41. 10.1038/s42004-018-0058-310.1038/s42004-018-0058-3 ↗
42. 10.1126/science.106318910.1126/science.1063189 ↗
43. 10.1088/0957-4484/20/23/23550210.1088/0957-4484/20/23/235502 ↗
44. 10.1021/acssensors.0c0076410.1021/acssensors.0c00764 ↗
45. 10.1063/1.485840010.1063/1.4858400 ↗
46. 10.1021/am404328g10.1021/am404328g ↗
47. 10.1039/c3nr05511f10.1039/c3nr05511f ↗
48. 10.1021/cr900296210.1021/cr9002962 ↗
49. 10.1109/TNANO.2018.280310610.1109/TNANO.2018.2803106 ↗
50. 10.1021/nl803930w10.1021/nl803930w ↗
51. 10.1021/nl803163610.1021/nl8031636 ↗