Electrical Evaluation of Bacterial Virulence Factors Using Nanopores
Source abstract
Abstract
In this work, we propose a novel methodology for electrical monitoring using nanoporous alumina membranes of virulence factors secreted by bacterial pathogens. Bacterial hyaluronidase (HYAL), which is produced by a number of invasive Gram-positive bacteria, is selected as a model compound to prove the concept. Our electrochemical setup takes advantage of the flat surface of indium tin oxide/poly(ethylene terephthalate) (ITO/PET) electrodes for their assembly with the nanoporous membrane. The proposed analytical method, based on the electrical monitoring of the steric/electrostatic nanochannels blocked upon formation of an antibody–HYAL immunocomplex, reached detection limits as low as 64 UI/mL (17.3 U/mg) HYAL. The inert surface of the ITO/PET electrodes together with the anti-biofilm properties of the 20 nm pore-sized alumina membranes allows for culturing the bacteria, capturing the secreted enzymes inside the nanochannels, and removing the cells before the electrochemical measurement. Secreted HYAL at levels of 1000 UI/mL (270 U/mg) are estimated in Gram-positive Staphylococcus aureus cultures, whereas low levels are detected for Gram-negative Pseudomonas aeruginosa (used as a negative control). Finally, HYAL secretion inhibition by RNAIII-inhibiting peptide (YSPWTNF-NH2) is also monitored, opening the way for further applications of the developed monitoring system for evaluation of the antivirulence potential of different compounds. This label-free method is rapid and cheap, avoiding the use of the time-consuming sandwich assays. We envisage future applications for monitoring of bacterial virulence/invasion as well as for testing of novel antimicrobial/antivirulence agents.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Nanopore and Nanochannel Transport Studies · Microfluidic and Bio-sensing Technologies · Microfluidic and Capillary Electrophoresis Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Grup de Biotecnologia Molecular i Industrial, Department of Chemical Engineering, Universitat Politècnica de Catalunya, Terrassa 08227, Spain
Funding
European Commission · Ministerio de Econom?a y Competitividad
References (28)
Show source-provided references
1. 10.1111/j.1574-6968.2000.tb08958.x10.1111/j.1574-6968.2000.tb08958.x ↗
2. 10.1128/IAI.01710-1410.1128/IAI.01710-14 ↗
3. 10.1128/IAI.74.1.40-48.200610.1128/IAI.74.1.40-48.2006 ↗
4. 10.4161/viru.2573010.4161/viru.25730 ↗
5. 10.1016/j.humic.2019.01.00110.1016/j.humic.2019.01.001 ↗
6. 10.2174/156802661766617010514331510.2174/1568026617666170105143315 ↗
7. 10.1021/cr050247k10.1021/cr050247k ↗
8. Yurish S. Y. · 2017 · 1
9. Grumezescu A. · 2016 · 8
10. 10.1039/c3cs35528d10.1039/c3cs35528d ↗
11. 10.1021/nn301368z10.1021/nn301368z ↗
12. 10.1021/nn303104710.1021/nn3031047 ↗
13. 10.1038/nnano.2009.1210.1038/nnano.2009.12 ↗
14. 10.1016/j.trac.2015.12.00310.1016/j.trac.2015.12.003 ↗
15. Losic D. · 201510.1007/978-3-319-20334-8 ↗
16. 10.1016/j.bios.2013.01.02410.1016/j.bios.2013.01.024 ↗
17. 10.1016/j.bios.2012.09.01610.1016/j.bios.2012.09.016 ↗
18. 10.1016/j.snb.2015.11.05910.1016/j.snb.2015.11.059 ↗
19. 10.3390/ma1006060310.3390/ma10060603 ↗
20. 10.1038/npjbiofilms.2015.2210.1038/npjbiofilms.2015.22 ↗
21. Ahani, A.; Saadati-Fard, L.; Sodagar, A. M.; Boroumad, F. A. In Flexible PET/ITO Electrode Array for Implantable Biomedical Applications, Conference Proceedings—IEEE Engineering in Medicine and Biology Society, 2011; pp 2878–2881.10.1109/IEMBS.2011.6090794 ↗
22. 10.1016/j.elecom.2010.04.00710.1016/j.elecom.2010.04.007 ↗
23. 10.1002/smll.20100234910.1002/smll.201002349 ↗
24. 10.1016/j.bios.2014.07.03910.1016/j.bios.2014.07.039 ↗
25. 10.1016/j.bios.2018.01.06410.1016/j.bios.2018.01.064 ↗
26. 10.1002/bmc.290910.1002/bmc.2909 ↗
27. 10.1155/2009/61437110.1155/2009/614371 ↗
28. 10.1016/S0196-9781(01)00496-X10.1016/S0196-9781(01)00496-X ↗