journal article·2007-02

Ultra-sensitive NEMS-based cantilevers for sensing, scanned probe and very high-frequency applications

Mo Li, H. X. Tang, M. L. Roukes

Nature Nanotechnology· Volume 2· Issue 2
Publisher page

Abstract

Scanning probe microscopies (SPM) and cantilever-based sensors generally use low-frequency mechanical devices of microscale dimensions or larger. Almost universally, off-chip methods are used to sense displacement in these devices, but this approach is not suitable for nanoscale devices. Nanoscale mechanical sensors offer a greatly enhanced performance that is unattainable with microscale devices. Here we describe the fabrication and operation of self-sensing nanocantilevers with fundamental mechanical resonances up to very high frequencies (VHF). These devices use integrated electronic displacement transducers based on piezoresistive thin metal films, permitting straightforward and optimal nanodevice readout. This non-optical transduction enables applications requiring previously inaccessible sensitivity and bandwidth, such as fast SPM and VHF force sensing. Detection of 127 MHz cantilever vibrations is demonstrated with a thermomechanical-noise-limited displacement sensitivity of 39 fm Hz(-1/2). Our smallest devices, with dimensions approaching the mean free path at atmospheric pressure, maintain high resonance quality factors in ambient conditions. This enables chemisorption measurements in air at room temperature, with unprecedented mass resolution less than 1 attogram (10(-18) g).
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Mechanical and Optical Resonators · Advanced MEMS and NEMS Technologies · Force Microscopy Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. Binnig, G., Quate, C. F. & Gerber, C. Atomic force microscope. Phys. Rev. Lett. 56, 930–933 (1986).10.1103/PhysRevLett.56.930 ↗
2. Binnig, G. et al. Atomic resolution with atomic force microscope. Europhys. Lett. 3, 1281–1286 (1987).10.1209/0295-5075/3/12/006 ↗
3. Meyer, E., Hug, H. J. & Bennewitz, R. Scanning Probe Microscopy: The Lab on a Tip (Springer, Berlin, New York, 2004).10.1007/978-3-662-09801-1 ↗
4. Wiesendanger, R. Scanning Probe Microscopy and Spectroscopy: Methods and Applications (Cambridge Univ. Press, Cambridge, UK, 1994).10.1017/CBO9780511524356 ↗
5. Lang, H. P. et al. Nanomechanics from atomic resolution to molecular recognition based on atomic force microscopy technology. Nanotechnology 13, R29–R36 (2002).10.1088/0957-4484/13/5/202 ↗
6. Lavrik, N. V., Sepaniak, M. J. & Datskos, P. G. Cantilever transducers as a platform for chemical and biological sensors. Rev. Sci. Instrum. 75, 2229–2253 (2004).10.1063/1.1763252 ↗
7. Yan, X. D., Ji, H. F. & Thundat, T. Microcantilever (mcl) biosensing. Curr. Anal. Chem. 2, 297–307 (2006).10.2174/157341106777698251 ↗
8. Albrecht, T. R. et al. Microfabrication of cantilever styli for the atomic force microscope. J. Vac. Sci. Technol. A 8, 3386–3396 (1990).10.1116/1.576520 ↗
9. Roukes, M. Nanoelectromechanical systems face the future. Phys. World 14, 25–31 (February 2001).10.1088/2058-7058/14/2/29 ↗
10. Cleland, A. N. & Roukes, M. L. A nanometre-scale mechanical electrometer. Nature 392, 160–162 (1998).10.1038/32373 ↗
11. Rugar, D. et al. Single spin detection by magnetic resonance force microscopy. Nature 430, 329–332 (2004).10.1038/nature02658 ↗
12. Yang, Y. T. et al. Zeptogram-scale nanomechanical mass sensing. Nano Lett. 6, 583–586 (2006).10.1021/nl052134m ↗
13. Mamin, H. J. & Rugar, D. Sub-attonewton force detection at millikelvin temperatures. Appl. Phys. Lett. 79, 3358–3360 (2001).10.1063/1.1418256 ↗
14. Naik, A. et al. Cooling a nanomechanical resonator with quantum back-action. Nature 443, 193–196 (2006).10.1038/nature05027 ↗
15. Schwab, K. C. & Roukes, M. L. Putting mechanics into quantum mechanics. Phys. Today 58, 36–42 (July 2005).10.1063/1.2012461 ↗
16. Tortonese, M., Barrett, R. C. & Quate, C. F. Atomic resolution with an atomic force microscope using piezoresistive detection. Appl. Phys. Lett. 62, 834–836 (1993).10.1063/1.108593 ↗
17. Parker, R. L. & Krinsky, A. Electrical resistance–strain characteristics of thin evaporated metal films. J. Appl. Phys. 34, 2700–2708 (1963).10.1063/1.1729795 ↗
18. Jen, S. U. et al. Piezoresistance and electrical resistivity of pd, au, and cu films. Thin Solid Films 434, 316–322 (2003).10.1016/S0040-6090(03)00504-2 ↗
19. Smith, C. S. Piezoresistance effect in germanium and silicon. Phys. Rev. 94, 42–49 (1954).10.1103/PhysRev.94.42 ↗
20. Kuczynski, G. C. Effect of elastic strain on the electrical resistance of metals. Phys. Rev. 94, 61–64 (1954).10.1103/PhysRev.94.61 ↗
21. Hooge, F. N. 1/f noise is no surface effect. Phys. Lett. A A 29, 139–140 (1969).10.1016/0375-9601(69)90076-0 ↗
22. Arlett, J. L. et al. Self-sensing micro- and nanocantilevers with attonewton-scale force resolution. Nano Lett. 6, 1000–1006 (2006).10.1021/nl060275y ↗
23. Harley, J. A. & Kenny, T. W. High-sensitivity piezoresistive cantilevers under 1000 angstrom thick. Appl. Phys. Lett. 75, 289–291 (1999).10.1063/1.124350 ↗
24. Femlab 3.1 (Comsol AB, Burlington, MA, USA).
25. Scofield, J. H. AC method for measuring low-frequency resistance fluctuation spectra. Rev. Sci. Instrum. 58, 985–993 (1987).10.1063/1.1139587 ↗
26. Rugar, D., Mamin, H. J. & Guethner, P. Improved fiber-optic interferometer for atomic force microscopy. Appl. Phys. Lett. 55, 2588–2590 (1989).10.1063/1.101987 ↗
27. Yasumura, K. Y. et al. Quality factors in micron- and submicron-thick cantilevers. J. Microelectromech. Syst. 9, 117–125 (2000).10.1109/84.825786 ↗
28. Newell, W. E. Miniaturization of tuning forks. Science 161, 1320–1326 (1968).10.1126/science.161.3848.1320 ↗
29. Bhiladvala, R. B. & Wang, Z. J. Effect of fluids on the q factor and resonance frequency of oscillating micrometer and nanometer scale beams. Phys. Rev. E 69, 036307 (2004).10.1103/PhysRevE.69.036307 ↗
30. Grate, J. W. & Abraham, M. H. Solubility interactions and the design of chemically selective sorbent coatings for chemical sensors and arrays. Sens. Actuator B-Chem. 3, 85–111 (1991).10.1016/0925-4005(91)80202-U ↗
31. Battiston, F. M. et al. A chemical sensor based on a microfabricated cantilever array with simultaneous resonance-frequency and bending readout. Sens. Actuator B-Chem. 77, 122–131 (2001).10.1016/S0925-4005(01)00683-9 ↗
32. Sidles, J. A. et al. Magnetic-resonance force microscopy. Rev. Mod. Phys. 67, 249–265 (1995).10.1103/RevModPhys.67.249 ↗
33. Arlett, J. L. et al. in Controlled Nanoscale Motion in Biological and Artificial Systems. Nobel symposium 131, June 2005; ed. Linke, H. et al. (Springer-Verlag, Heidelberg, in press).
34. Ekinci, K. L., Yang, Y. T. & Roukes, M. L. Ultimate limits to inertial mass sensing based upon nanoelectromechanical systems. J. Appl. Phys. 95, 2682–2689 (2004).10.1063/1.1642738 ↗
35. Yang, Y. T. et al. Monocrystalline silicon carbide nanoelectromechanical systems. Appl. Phys. Lett. 78, 162–164 (2001).10.1063/1.1338959 ↗