journal article·2022-06

Porosity-based heterojunctions enable leadless optoelectronic modulation of tissues

Aleksander Prominski, Jiuyun Shi, Pengju Li, Jiping Yue, Yiliang Lin, Jihun Park, Bozhi Tian, Menahem Y. Rotenberg

Nature Materials· Volume 21· Issue 6
Publisher page

Abstract

Homo- and heterojunctions play essential roles in semiconductor-based devices such as field-effect transistors, solar cells, photodetectors and light-emitting diodes. Semiconductor junctions have been recently used to optically trigger biological modulation via photovoltaic or photoelectrochemical mechanisms. The creation of heterojunctions typically involves materials with different doping or composition, which leads to high cost, complex fabrications and potential side effects at biointerfaces. Here we show that a porosity-based heterojunction, a largely overlooked system in materials science, can yield an efficient photoelectrochemical response from the semiconductor surface. Using self-limiting stain etching, we create a nanoporous/non-porous, soft-hard heterojunction in p-type silicon within seconds under ambient conditions. Upon surface oxidation, the heterojunction yields a strong photoelectrochemical response in saline. Without any interconnects or metal modifications, the heterojunction enables efficient non-genetic optoelectronic stimulation of isolated rat hearts ex vivo and sciatic nerves in vivo with optical power comparable to optogenetics, and with near-infrared capabilities.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Neuroscience and Neural Engineering · Advanced Memory and Neural Computing · Nanowire Synthesis and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (48)

Show source-provided references
1. Feiner, R. et al. Engineered hybrid cardiac patches with multifunctional electronics for online monitoring and regulation of tissue function. Nat. Mater. 15, 679–685 (2016).10.1038/nmat4590 ↗
2. Fang, H. et al. Capacitively coupled arrays of multiplexed flexible silicon transistors for long-term cardiac electrophysiology. Nat. Biomed. Eng. 1, 0038 (2017).10.1038/s41551-017-0055 ↗
3. Xu, L. et al. 3D multifunctional integumentary membranes for spatiotemporal cardiac measurements and stimulation across the entire epicardium. Nat. Commun. 5, 3329 (2014).10.1038/ncomms4329 ↗
4. Kim, D. H. et al. Epidermal electronics. Science 333, 838–843 (2011).10.1126/science.1206157 ↗
5. Jiang, Y. et al. Rational design of silicon structures for optically controlled multiscale biointerfaces. Nat. Biomed. Eng. 2, 508–521 (2018).10.1038/s41551-018-0230-1 ↗
6. Feiner, R. & Dvir, T. Tissue–electronics interfaces: from implantable devices to engineered tissues. Nat. Rev. Mater. 3, 17076 (2017).10.1038/natrevmats.2017.76 ↗
7. Murphy, J. J. Current practice and complications of temporary transvenous cardiac pacing. Brit. Med. J. 312, 1134 (1996).10.1136/bmj.312.7039.1134 ↗
8. Austin, J. L., Preis, L. K., Crampton, R. S., Beller, G. A. & Martin, R. P. Analysis of pacemaker malfunction and complications of temporary pacing in the coronary care unit. Am. J. Cardiol. 49, 301–306 (1982).10.1016/0002-9149(82)90505-7 ↗
9. Betts, T. R. Regional survey of temporary transvenous pacing procedures and complications. Postgrad. Med. J. 79, 463–465 (2003).10.1136/pmj.79.934.463 ↗
10. Nolewajka, A. J., Goddard, M. D. & Brown, T. C. Temporary transvenous pacing and femoral vein thrombosis. Circulation 62, 646–650 (1980).10.1161/01.CIR.62.3.646 ↗
11. Rossillo, A. et al. Impact of coronary sinus lead position on biventricular pacing: mortality and echocardiographic evaluation during long-term follow-up. J. Cardiovasc. Electrophysiol. 15, 1120–1125 (2004).10.1046/j.1540-8167.2004.04089.x ↗
12. Peschar, M., de Swart, H., Michels, K. J., Reneman, R. S. & Prinzen, F. W. Left ventricular septal and apex pacing for optimal pump function in canine hearts. J. Am. Coll. Cardiol. 41, 1218–1226 (2003).10.1016/S0735-1097(03)00091-3 ↗
13. Wells, J. et al. Optical stimulation of neural tissue in vivo. Opt. Lett. 30, 504–506 (2005).10.1364/OL.30.000504 ↗
14. Wells, J., Konrad, P., Kao, C., Jansen, E. D. & Mahadevan-Jansen, A. Pulsed laser versus electrical energy for peripheral nerve stimulation. J. Neurosci. Methods 163, 326–337 (2007).10.1016/j.jneumeth.2007.03.016 ↗
15. Jenkins, M. W. et al. Optical pacing of the embryonic heart. Nat. Photon. 4, 623–626 (2010).10.1038/nphoton.2010.166 ↗
16. Jenkins, M. W. et al. Optical pacing of the adult rabbit heart. Biomed. Opt. Express 4, 1626–1635 (2013).10.1364/BOE.4.001626 ↗
17. McCall, J. G. et al. Preparation and implementation of optofluidic neural probes for in vivo wireless pharmacology and optogenetics. Nat. Protoc. 12, 219–237 (2017).10.1038/nprot.2016.155 ↗
18. Montgomery, K. L. et al. Wirelessly powered, fully internal optogenetics for brain, spinal and peripheral circuits in mice. Nat. Methods 12, 969–974 (2015).10.1038/nmeth.3536 ↗
19. Nussinovitch, U. & Gepstein, L. Optogenetics for in vivo cardiac pacing and resynchronization therapies. Nat. Biotechnol. 33, 750–754 (2015).10.1038/nbt.3268 ↗
20. Koo, J. et al. Wireless bioresorbable electronic system enables sustained nonpharmacological neuroregenerative therapy. Nat. Med. 24, 1830–1836 (2018).10.1038/s41591-018-0196-2 ↗
21. Choi, Y. S. et al. Fully implantable and bioresorbable cardiac pacemakers without leads or batteries. Nat. Biotechnol. 39, 1228–1238 (2021).10.1038/s41587-021-00948-x ↗
22. Piech, D. K. et al. A wireless millimetre-scale implantable neural stimulator with ultrasonically powered bidirectional communication. Nat. Biomed. Eng. 4, 207–222 (2020).10.1038/s41551-020-0518-9 ↗
23. Jiang, Y. & Tian, B. Inorganic semiconductor biointerfaces. Nat. Rev. Mater. 3, 473–490 (2018).10.1038/s41578-018-0062-3 ↗
24. Rotenberg, M. Y. & Tian, B. Talking to cells: semiconductor nanomaterials at the cellular interface. Adv. Biosyst. 2, 1700242 (2018).10.1002/adbi.201700242 ↗
25. Silvera Ejneby, M. et al. Chronic electrical stimulation of peripheral nerves via deep-red light transduced by an implanted organic photocapacitor. Nat. Biomed. Eng. https://doi.org/10.1038/s41551-021-00817-7 (2021).10.1038/s41551-021-00817-7 ↗
26. Yan, F., Bao, X.-M. & Gao, T. Photovoltage spectra of silicon/porous silicon heterojunction. Solid State Commun. 91, 341–343 (1994).10.1016/0038-1098(94)90630-0 ↗
27. Palsule, C. et al. Electrical and optical characterization of crystalline silicon/porous silicon heterojunctions. Sol. Energy Mater. Sol. Cells 46, 261–269 (1997).10.1016/S0927-0248(97)00004-4 ↗
28. Suntao, W., Yanhua, W. & Qihua, S. Measurement and analysis of the characteristic parameters for the porous silicon/silicon using photovoltage spectra. Appl. Surf. Sci. 158, 268–274 (2000).10.1016/S0169-4332(00)00008-8 ↗
29. Fang, Y. et al. Micelle-enabled self-assembly of porous and monolithic carbon membranes for bioelectronic interfaces. Nat. Nanotechnol. 16, 206–213 (2021).10.1038/s41565-020-00805-z ↗
30. Jiang, Y. et al. Heterogeneous silicon mesostructures for lipid-supported bioelectric interfaces. Nat. Mater. 15, 1023–1030 (2016).10.1038/nmat4673 ↗
31. Kolasinski, K. W. in Handbook of Porous Silicon (ed. Canham, L.) Ch. 4 (Springer, 2018).
32. Yerokhov, V. Y. & Melnyk, I. I. Porous silicon in solar cell structures: a review of achievements and modern directions of further use. Renew. Sustain. Energy Rev. 3, 291–322 (1999).10.1016/S1364-0321(99)00005-2 ↗
33. Alhmoud, H., Brodoceanu, D., Elnathan, R., Kraus, T. & Voelcker, N. H. A MACEing silicon: towards single-step etching of defined porous nanostructures for biomedicine. Prog. Mater. Sci. 116, 100636 (2021).10.1016/j.pmatsci.2019.100636 ↗
34. Hopcroft, M. A., Nix, W. D. & Kenny, T. W. What is the Young’s modulus of silicon? J. Microelectromech. Syst. 19, 229–238 (2010).10.1109/JMEMS.2009.2039697 ↗
35. Jiang, Y. et al. Nongenetic optical neuromodulation with silicon-based materials. Nat. Protoc. 14, 1339–1376 (2019).10.1038/s41596-019-0135-9 ↗
36. Glunz, S. W. & Feldmann, F. SiO2 surface passivation layers – a key technology for silicon solar cells. Sol. Energy Mater. Sol. Cells 185, 260–269 (2018).10.1016/j.solmat.2018.04.029 ↗
37. Nosaka, Y. & Nosaka, A. Y. Generation and detection of reactive oxygen species in photocatalysis. Chem. Rev. 117, 11302–11336 (2017).10.1021/acs.chemrev.7b00161 ↗
38. Tampo, H., Kim, S., Nagai, T., Shibata, H. & Niki, S. Improving the open circuit voltage through surface oxygen plasma treatment and 11.7% efficient Cu2ZnSnSe4 solar cell. ACS Appl. Mater. Interfaces 11, 13319–13325 (2019).10.1021/acsami.9b01756 ↗
39. Parameswaran, R. et al. Optical stimulation of cardiac cells with a polymer-supported silicon nanowire matrix. Proc. Natl Acad. Sci. USA 116, 413–421 (2019).10.1073/pnas.1816428115 ↗
40. Bruegmann, T. et al. Optogenetic control of heart muscle in vitro and in vivo. Nat. Methods 7, 897–900 (2010).10.1038/nmeth.1512 ↗
41. Jacques, S. L. Optical properties of biological tissues: a review. Phys. Med. Biol. 58, R37–61 (2013).10.1088/0031-9155/58/11/R37 ↗
42. Ushiki, T. & Ide, C. Three-dimensional organization of the collagen fibrils in the rat sciatic nerve as revealed by transmission- and scanning electron microscopy. Cell Tissue Res. 260, 175–184 (1990).10.1007/BF00297503 ↗
43. Koutsou, A. D., Moreno, J. C., del Ama, A. J., Rocon, E. & Pons, J. L. Advances in selective activation of muscles for non-invasive motor neuroprostheses. J. Neuroeng. Rehabilitation 13, 56 (2016).10.1186/s12984-016-0165-2 ↗
44. Badia, J. et al. Comparative analysis of transverse intrafascicular multichannel, longitudinal intrafascicular and multipolar cuff electrodes for the selective stimulation of nerve fascicles. J. Neural Eng. 8, 036023 (2011).10.1088/1741-2560/8/3/036023 ↗
45. Strauss, I. et al. Q-PINE: a quick to implant peripheral intraneural electrode. J. Neural Eng. 17, 066008 (2020).10.1088/1741-2552/abc52a ↗
46. Guo, J. et al. Highly stretchable, strain sensing hydrogel optical fibers. Adv. Mater. 28, 10244–10249 (2016).10.1002/adma.201603160 ↗
47. Kahlert, H. in Electroanalytical Methods (eds Fritz Scholz et al.) Ch. 15 (Springer Berlin Heidelberg, 2010).
48. Oliver, W. C. & Pharr, G. M. An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments. J. Mater. Res. 7, 1564–1583 (1992).10.1557/JMR.1992.1564 ↗