journal article·2026-01-28

Glucose Oxidase/ o -Phenylenediamine Interfaces on Dendritic Pt Microneedles for Highly Sensitive and Selective Continuous Glucose Monitoring Sensors

Hyeong Jun Kim, Byeong Jun So, Yuseung Choi, Eun Jae Nam, Gilyong Shin, Ju Hwan Lee, Tae June Kang

Publisher page

Abstract

Microneedle-based glucose sensors offer a minimally invasive and wearable platform for real-time monitoring. However, conventional enzyme immobilization methods often lack spatial precision and show limited compatibility with miniaturized electrode architectures. Here, we present an electrodeposition strategy for localized and controlled immobilization of glucose oxidase at microneedle tips. Dendritic platinum was engineered via potentiostatic diffusion-limited growth, significantly increasing electroactive surface area and enzyme loading capacity. This yielded an enhanced catalytic response with a maximum current density of ∼200 μA/cm 2 during glucose oxidation, thereby improving sensitivity. To ensure selectivity, o -phenylenediamine electropolymerization time was optimized to balance glucose permeability with suppression of electroactive interferents, reducing interferent-to-glucose current ratios to below 4.0% in artificial interstitial fluid. In human trials, the microneedle sensor operated stably and exhibited a sensitivity of 137.7 nA·(mg/dL) −1 (≈2.48 μA·mM –1 ), with strong linearity ( R 2 = 0.940) across 82–211 mg/dL (≈4.6–11.7 mM). This scalable and tunable fabrication approach addresses the dual challenge of achieving high sensitivity and selectivity in miniaturized enzymatic sensors, offering broad potential for wearable biosensing and personalized healthcare technologies.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Advancements in Transdermal Drug Delivery · Advanced Nanomaterials in Catalysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical Engineering, Inha University, 100 Inha-ro, Michuhol-gu, Incheon 22212, Republic of Korea

Department of Materials Science Engineering, University of California, Los Angeles, 410 Westwood Plaza, Los Angeles, California 90095, United States

Funding

Rural Development Administration · National Research Foundation of Korea

References (50)

Show source-provided references
1. 10.1021/acs.analchem.6b0463010.1021/acs.analchem.6b04630 ↗
2. 10.1021/acsami.5c1405410.1021/acsami.5c14054 ↗
3. 10.1038/nrendo.2017.310.1038/nrendo.2017.3 ↗
4. 10.3390/s2205203010.3390/s22052030 ↗
5. 10.1089/dia.2022.001110.1089/dia.2022.0011 ↗
6. 10.2337/dc19-207310.2337/dc19-2073 ↗
7. 10.1097/AJP.0b013e31816778f910.1097/AJP.0b013e31816778f9 ↗
8. 10.1126/scitranslmed.aaw028510.1126/scitranslmed.aaw0285 ↗
9. 10.1073/pnas.171677211510.1073/pnas.1716772115 ↗
10. 10.1021/acsami.4c2205410.1021/acsami.4c22054 ↗
11. 10.1016/j.device.2023.10011210.1016/j.device.2023.100112 ↗
12. 10.1038/s41551-022-00887-110.1038/s41551-022-00887-1 ↗
13. 10.1038/s41378-021-00302-w10.1038/s41378-021-00302-w ↗
14. 10.1039/D4LC00365A10.1039/D4LC00365A ↗
15. 10.1016/j.bios.2018.08.01010.1016/j.bios.2018.08.010 ↗
16. 10.1016/j.biotechadv.2011.09.00310.1016/j.biotechadv.2011.09.003 ↗
17. 10.1016/j.bios.2006.06.00910.1016/j.bios.2006.06.009 ↗
18. 10.1016/S0956-5663(00)00101-910.1016/S0956-5663(00)00101-9 ↗
19. 10.3390/chemosensors1106034510.3390/chemosensors11060345 ↗
20. 10.1016/S0925-4005(99)00163-X10.1016/S0925-4005(99)00163-X ↗
21. 10.1039/b403035d10.1039/b403035d ↗
22. 10.1006/abio.2000.450210.1006/abio.2000.4502 ↗
23. 10.1016/j.snb.2012.12.07710.1016/j.snb.2012.12.077 ↗
24. 10.1016/j.bios.2024.11628010.1016/j.bios.2024.116280 ↗
25. 10.1021/acsami.3c1274010.1021/acsami.3c12740 ↗
26. 10.1007/s10544-018-0349-610.1007/s10544-018-0349-6 ↗
27. 10.1002/adfm.20200985010.1002/adfm.202009850 ↗
28. 10.1007/s00216-016-9961-610.1007/s00216-016-9961-6 ↗
29. 10.1039/C8CS00848E10.1039/C8CS00848E ↗
30. 10.1351/pac19916305071110.1351/pac199163050711 ↗
31. 10.2337/db13-113210.2337/db13-1132 ↗
32. 10.1177/19322968110050050410.1177/193229681100500504 ↗
33. 10.1016/j.actbio.2021.08.04510.1016/j.actbio.2021.08.045 ↗
34. 10.1038/s41567-020-0930-910.1038/s41567-020-0930-9 ↗
35. 10.1016/j.microc.2024.11111310.1016/j.microc.2024.111113 ↗
36. 10.1021/jp013219o10.1021/jp013219o ↗
37. 10.1002/adma.20110218210.1002/adma.201102182 ↗
38. 10.20964/2016.06.7110.20964/2016.06.71 ↗
39. 10.2337/diacare.10.5.62210.2337/diacare.10.5.622 ↗
40. 10.3390/chemosensors302005510.3390/chemosensors3020055 ↗
41. 10.1016/0003-2670(94)00374-U10.1016/0003-2670(94)00374-U ↗
42. 10.1111/jdi.1369210.1111/jdi.13692 ↗
43. 10.1021/bi00865a01810.1021/bi00865a018 ↗
44. 10.1016/0003-2697(75)90497-210.1016/0003-2697(75)90497-2 ↗
45. 10.1021/acs.chemrev.2c0034410.1021/acs.chemrev.2c00344 ↗
46. 10.1038/s41551-018-0273-310.1038/s41551-018-0273-3 ↗
47. 10.1016/j.biomaterials.2012.10.04910.1016/j.biomaterials.2012.10.049 ↗
48. 10.1021/cr068069y10.1021/cr068069y ↗
49. 10.1016/S0379-6779(01)00520-310.1016/S0379-6779(01)00520-3 ↗
50. 10.1016/j.metabol.2023.15564010.1016/j.metabol.2023.155640 ↗