journal article·2023-03-08

Reusable, Ultrasensitive, Patterned Conjugated Polyelectrolyte–Surfactant Complex Film with a Wide Detection Range for Copper Ion Detection

Young-Jae Jin, Beom-Min Si, Eonji Kim, Jineun Lee, Heesang Kim, Giseop Kwak, Toshikazu Sakaguchi, Jinhee Lee, In Young Song, Chang-Lyoul Lee, Joon Heon Kim, Kyuyoung Heo, Wang-Eun Lee

Publisher page

Abstract

Conjugated polyelectrolytes (CPEs) are emerging as promising materials in the sensor field because they enable high-sensitivity detection of various substances in aqueous media. However, most CPE-based sensors have serious problems in real-world application because the sensor system is operated only when the CPE is dissolved in aqueous media. Here, the fabrication and performance of a water-swellable (WS) CPE-based sensor driven in the solid state are demonstrated. The WS CPE films are prepared by immersing a water-soluble CPE film in cationic surfactants of different alkyl chain lengths in a chloroform solution. The prepared film exhibits rapid, limited water swellability despite the absence of chemical crosslinking. The water swellability of the film enables the highly sensitive and selective detection of Cu 2+ in water. The fluorescence quenching constant and the detection limit of the film are 7.24 × 10 6 L mol –1 and 4.38 nM (0.278 ppb), respectively. Moreover, the film is reusable via a facile treatment. Furthermore, various fluorescent patterns introduced by different surfactants are successfully fabricated by a simple stamping method. By integrating the patterns, Cu 2+ detection in a wide concentration range (nM–mM) can be achieved.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Luminescence and Fluorescent Materials · Molecular Sensors and Ion Detection · Conducting polymers and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Reliability Assessment Center for Chemical Materials, Korea Research Institute of Chemical Technology (KRICT), 141 Gajeong-ro, Yuseong-gu, Daejeon 34114, South Korea

Department of Polymer Science & Engineering, Polymeric Nanomaterials Laboratory, Kyungpook National University, 1370 Sankyuk-dong, Buk-ku, Daegu 41566, South Korea

Department of Materials Science and Engineering, Graduate School of Engineering, University of Fukui, Bunkyo 3-9-1, Fukui 910-8507, Japan

Advanced Photonics Research Institute, Gwangju Institute of Science and Technology, 1 Oryong-dong, Buk-gu, Gwangju 61005, South Korea

Funding

Korea Research Institute of Chemical Technology

References (72)

Show source-provided references
1. Luch, A. Molecular, Clinical and Environmental Toxicology: Volume 3: Environmental Toxicology; Springer Basel, 2012; p 133.10.1007/978-3-7643-8340-4 ↗
2. 10.1021/acs.chemrev.8b0026010.1021/acs.chemrev.8b00260 ↗
3. 10.1021/acs.chemrev.8b0022610.1021/acs.chemrev.8b00226 ↗
4. 10.1021/acs.chemrev.8b0017110.1021/acs.chemrev.8b00171 ↗
5. 10.1021/acs.chemrev.8b0038110.1021/acs.chemrev.8b00381 ↗
6. 10.1021/acs.chemrev.8b0001610.1021/acs.chemrev.8b00016 ↗
7. Banica F.-G. · 201210.1002/9781118354162 ↗
8. 10.1021/am302866210.1021/am3028662 ↗
9. 10.1016/j.snb.2018.06.11810.1016/j.snb.2018.06.118 ↗
10. 10.1021/acssensors.1c0117210.1021/acssensors.1c01172 ↗
11. 10.1515/revac-210.1515/revac-2 ↗
12. 10.3390/s1920437610.3390/s19204376 ↗
13. 10.1021/cr980101410.1021/cr9801014 ↗
14. 10.1021/ar700115t10.1021/ar700115t ↗
15. 10.1021/ar700248910.1021/ar7002489 ↗
16. 10.1039/c0an00239a10.1039/c0an00239a ↗
17. 10.1002/adma.20180670110.1002/adma.201806701 ↗
18. 10.1021/ja00240a04410.1021/ja00240a044 ↗
19. 10.1002/anie.20080545610.1002/anie.200805456 ↗
20. 10.1021/acs.chemrev.8b0077310.1021/acs.chemrev.8b00773 ↗
21. 10.1002/adma.20080053310.1002/adma.200800533 ↗
22. 10.1021/cm049587x10.1021/cm049587x ↗
23. 10.1021/ja801196310.1021/ja8011963 ↗
24. 10.1021/cr200263w10.1021/cr200263w ↗
25. 10.1016/j.chempr.2017.05.00210.1016/j.chempr.2017.05.002 ↗
26. 10.1038/ncomms473610.1038/ncomms4736 ↗
27. 10.1039/d0an02286a10.1039/d0an02286a ↗
28. 10.1167/iovs.16-2055610.1167/iovs.16-20556 ↗
29. 10.1136/bmjopen-2021-05412010.1136/bmjopen-2021-054120 ↗
30. 10.1055/s-0034-136858910.1055/s-0034-1368589 ↗
31. 10.1021/acssensors.8b0009310.1021/acssensors.8b00093 ↗
32. 10.1021/ma101941310.1021/ma1019413 ↗
33. 10.1002/adfm.20100173810.1002/adfm.201001738 ↗
34. 10.1021/cr050133910.1021/cr0501339 ↗
35. 10.1021/ma802506x10.1021/ma802506x ↗
36. 10.1002/anie.20090662110.1002/anie.200906621 ↗
37. 10.1002/adma.20120196710.1002/adma.201201967 ↗
38. 10.1002/adfm.20130282910.1002/adfm.201302829 ↗
39. 10.1002/pola.2368710.1002/pola.23687 ↗
40. 10.1002/admi.20140036010.1002/admi.201400360 ↗
41. 10.1039/c3cc45538f10.1039/c3cc45538f ↗
42. 10.1002/adfm.20160088910.1002/adfm.201600889 ↗
43. 10.1021/la011701s10.1021/la011701s ↗
44. 10.1021/la060519u10.1021/la060519u ↗
45. 10.1021/cr040410w10.1021/cr040410w ↗
46. 10.1007/s00018-007-7439-610.1007/s00018-007-7439-6 ↗
47. 10.1038/ng1293-32710.1038/ng1293-327 ↗
48. 10.1007/s00775-009-0600-y10.1007/s00775-009-0600-y ↗
49. 10.1021/nn402037x10.1021/nn402037x ↗
50. 10.1021/acssensors.7b0040010.1021/acssensors.7b00400 ↗
51. 10.1039/c6ay02416e10.1039/c6ay02416e ↗
52. 10.1016/j.jphotochemrev.2017.06.00210.1016/j.jphotochemrev.2017.06.002 ↗
53. 10.1007/s10895-017-2178-z10.1007/s10895-017-2178-z ↗
54. 10.1515/revac-2020-011810.1515/revac-2020-0118 ↗
55. 10.1021/ac051010r10.1021/ac051010r ↗
56. 10.1007/s10895-020-02503-410.1007/s10895-020-02503-4 ↗
57. 10.1002/adfm.20060105610.1002/adfm.200601056 ↗
58. 10.1021/ar960050210.1021/ar9600502 ↗
59. 10.1021/am400939w10.1021/am400939w ↗
60. 10.1116/1.514389710.1116/1.5143897 ↗
61. 10.1063/1.477358310.1063/1.4773583 ↗
62. 10.1002/sia.252810.1002/sia.2528 ↗
63. 10.1016/j.eti.2017.07.00210.1016/j.eti.2017.07.002 ↗
64. 10.1016/j.snb.2013.12.03710.1016/j.snb.2013.12.037 ↗
65. Industrial Test Systems, Inc. SenSafe Copper (John’s) Test Strips. at. https://sensafe.com/sensafe-copper-johns/ (accessed Nov 08, 2022).
66. KYORITSU CHEMICAL-CHECK Lab. PACKTEST Copper (DDTC), Model: WAK-CuM-2. at. https://en.kyoritsu-lab.co.jp/products/wak_cum_2 (accessed Nov 08, 2022)
67. Cole-Parmer. Advantec 07030020 Test Strips, Copper Check (Cu2+). at. https://www.coleparmer.com/i/advantec-07030020-test-strips-copper-check-cu2-0-to-500-ppm-100-strips-pk/5920112 (accessed Nov 08, 2022).
68. Cole-Parmer. Advantec 07030030 Test Strips, Copper Check A (Cu+ and Cu2+). at. https://www.coleparmer.com/i/advantec-07030030-test-strips-copper-check-a-cu-and-cu2-0-to-50-ppm-100-strips-pk/5920114 (accessed Nov 08, 2022).
69. Mettler Toledo. DX264-Cu Copper half-cell. at. https://www.mt.com/gb/en/home/products/Laboratory_Analytics_Browse/Product_Family_Browse_titrators_main/Product_Family_Titration_Sensors/Titration_Ion_Selective_sensors_Fami/DX264_Copper_Half_Cell.html (accessed Nov 08, 2022).
70. THERMO FISHER, Moving from ICP to XSERIES 2 ICP-MS for Environmental Analysis. at. http://tools.thermofisher.com/content/sfs/brochures/D00670?pdf (accessed Nov 08, 2022).
71. James, H. US EPA Method 200.7 using the Thermo Scientific iCAP 7600 ICP-OES Duo. at. https://www.scispec.co.th/app/ICP/TICPO01002.pdf (accessed Nov 08, 2022).
72. 10.1021/ma00047a03810.1021/ma00047a038 ↗