Abstract

Electrofluidics is the unique combination of electrophoresis and microfluidics, which has opened up broad opportunities for bioanalysis and multiplexed assay. These systems typically comprise inaccessible and fully enclosed microcapillary or microchannels, with limited sample loading capacities and no direct access to the solutes within. Here, we investigate the application of multiyarn textile assemblies which provides an open and surface accessible electrophoretic separation platform. Three-dimensional (3D) textile structures have been produced using conventional knitting and braiding techniques from a range of commercially available yarns. Capillary zone electrophoresis separation studies have been carried out on these substrates using fluorescent anionic (fluorescence, FL) and cationic (rhodamine-B, Rh-B) markers. The effects of different yarn surface chemistry, textile fabrication technique, and electrolyte ionic strength on the electrophoretic mobility of the test analytes have been studied. From the broad range of yarns investigated, polyester was shown to have the highest electrophoretic mobility for Rh-B (6 × 10–4 cm2 V–1 s–1) and for FL (4 × 10–4 cm2 V–1 s–1). The braiding approach, being simple and versatile, was found to be the most effective route to produce 3D textile-based structures and offered the potential for selective movement and targeted delivery to different channels. Composite braids made with yarns of differential surface chemistries further revealed a unique behavior of separation and parallel movement of oppositely charged ionic species. We also demonstrate the feasibility to apply isotachophoresis (ITP) on these braided textile substrates to rapidly focus dispersed FL sample bands. Here, we demonstrate the focusing of FL from a dispersed band into narrow band with a 400 times reduction in sample width over 90 s. Owing to the simplicity and reproducibility of the developed approach, textile-based inverted microfluidic applications are expected to enable opportunities in bioanalysis, proteomics, and rapid clinical diagnostics.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Biosensors and Analytical Detection · Advanced Sensor and Energy Harvesting Materials · Electrowetting and Microfluidic Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

ARC Centre of Excellence for Electromaterials Science (ACES), AIIM Facility, Innovation Campus, University of Wollongong, Wollongong, New South Wales 2500, Australia

Department of Fibre and Textile Technology, University of Agriculture, Faisalabad 38000, Pakistan

Australian National Fabrication Facility—Materials Node, Innovation Campus, University of Wollongong, Wollongong, New South Wales 2500, Australia

Australian Centre for Research on Separation Science (ACROSS) and ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7005, Australia

Funding

Australian Research Council · Higher Education Commission, Pakistan · Centre of Excellence for Electromaterials Science, Australian Research Council

References (38)

Show source-provided references
1. 10.1038/nature0505810.1038/nature05058 ↗
2. 10.1039/c2lc90022j10.1039/c2lc90022j ↗
3. 10.1021/ac303154310.1021/ac3031543 ↗
4. 10.1038/nature0506410.1038/nature05064 ↗
5. 10.4155/bio.15.16410.4155/bio.15.164 ↗
6. 10.1021/am100226610.1021/am1002266 ↗
7. 10.1021/am900614810.1021/am9006148 ↗
8. 10.1126/science.288.5463.11310.1126/science.288.5463.113 ↗
9. 10.1016/j.sna.2003.12.01310.1016/j.sna.2003.12.013 ↗
10. 10.1117/1.360743010.1117/1.3607430 ↗
11. 10.1021/acscombsci.8b0012610.1021/acscombsci.8b00126 ↗
12. 10.1016/j.bios.2019.03.00910.1016/j.bios.2019.03.009 ↗
13. 10.1016/j.aca.2017.02.04010.1016/j.aca.2017.02.040 ↗
14. 10.1016/j.snb.2017.04.14410.1016/j.snb.2017.04.144 ↗
15. 10.1021/am505849e10.1021/am505849e ↗
16. 10.1016/j.bios.2017.07.07010.1016/j.bios.2017.07.070 ↗
17. 10.1002/elan.20170057910.1002/elan.201700579 ↗
18. 10.1016/j.cclet.2016.07.02110.1016/j.cclet.2016.07.021 ↗
19. 10.1039/C4AN00201F10.1039/C4AN00201F ↗
20. 10.1039/C5LC00937E10.1039/C5LC00937E ↗
21. Wei, Y. C.; Su, S. Y.; Fu, L. M.; Lin, C. H. In Electrophoresis Separation and Electrochemical Detection on a Novel Line-Based Microfluidic Device, 2012 IEEE 25th International Conference on Micro Electro Mechanical Systems (MEMS); IEEE, Feb 02, 2012; pp 104–107.10.1109/MEMSYS.2012.6170104 ↗
22. 10.1016/j.jpba.2015.03.00210.1016/j.jpba.2015.03.002 ↗
23. 10.1039/D0AN01344G10.1039/D0AN01344G ↗
24. 10.1039/C6AN01515H10.1039/C6AN01515H ↗
25. 10.1016/j.aca.2017.10.02910.1016/j.aca.2017.10.029 ↗
26. 10.1007/s10404-012-1076-610.1007/s10404-012-1076-6 ↗
27. 10.1016/j.snb.2019.01.16810.1016/j.snb.2019.01.168 ↗
28. Wei, Y. C.; Lin, C. H. In Capillary Electrophoresis and Electrospray Ionization on a Single-Thread Microfluidic System for Rapid Mass Spectrometry Detection, 2016 IEEE 29th International Conference on Micro Electro Mechanical Systems (MEMS); IEEE, 2016; pp 485–488.
29. 10.1039/C4AY01071J10.1039/C4AY01071J ↗
30. 10.1177/004051751452856510.1177/0040517514528565 ↗
31. 10.1039/C4LC01135J10.1039/C4LC01135J ↗
32. 10.1039/C1LC20764D10.1039/C1LC20764D ↗
33. 10.1063/1.356709410.1063/1.3567094 ↗
34. 10.1021/ac504512710.1021/ac5045127 ↗
35. 10.1016/j.chroma.2007.08.08310.1016/j.chroma.2007.08.083 ↗
36. 10.1111/j.1478-4408.2005.tb00277.x10.1111/j.1478-4408.2005.tb00277.x ↗
37. 10.1016/S0021-9673(00)01057-810.1016/S0021-9673(00)01057-8 ↗
38. 10.1039/C7LC00852J10.1039/C7LC00852J ↗