Double Electrode Experiments Reveal the Processes Occurring at PEDOT-Coated Neural Electrode Arrays
Source abstract
Abstract
Neural electrodes have recently been developed with surface modifications of conductive polymers, in particular poly(3,4-ethylenedioxythiophene) (PEDOT), and extensively studied for their roles in recording and stimulation, aiming to improve their biocompatibility. In this work, the implications for the design of practical neural sensors are clarified, and systematic procedures for their preparation are reported. In particular, this study introduces the use of in vitro double electrode experiments to mimic the responses of neural electrodes with a focus on signal-recording electrodes modified with PEDOT. Specifically, potential steps on one unmodified electrode in an array are used to identify the responses for PEDOT doped with different anions and compared with that of a bare platinum (Pt) electrode. The response is shown to be related to the rearrangement of ions in solution near the detector electrode resulting from the potential step, with a current transient seen at the detector electrode. A rapid response for PEDOT doped with chloride (ca. 0.04 s) ions was observed and attributed to the fast movement of chloride ions in and out of the polymer film. In contrast, PEDOT doped with poly(styrenesulfonate) (PSS) responds much slower (ca. 2.2 s), and the essential immobility of polyanion constrains the direction of current flow.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Neuroscience and Neural Engineering · Conducting polymers and applications · Advanced Memory and Neural Computing
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Clarendon Laboratory, Department of Physics, University of Oxford, Parks Road, Oxford OX1 3PU, Great Britain
Physical and Theoretical Chemistry Laboratory, Department of Chemistry, University of Oxford, South Parks Road, Oxford OX1 3QZ, Great Britain
References (48)
Show source-provided references
1. 10.1038/s41583-019-0140-610.1038/s41583-019-0140-6 ↗
2. 10.1126/science.125.3247.54910.1126/science.125.3247.549 ↗
3. 10.1109/TBME.1970.450273810.1109/TBME.1970.4502738 ↗
4. 10.1109/TNSRE.2003.81444310.1109/TNSRE.2003.814443 ↗
5. 10.1109/10.8358810.1109/10.83588 ↗
6. Campbell P. K. · Biomed. Sci. Instrum · 1990 · 26 · 161
7. 10.1016/0165-0270(83)90097-310.1016/0165-0270(83)90097-3 ↗
8. 10.1016/0165-0270(95)00085-210.1016/0165-0270(95)00085-2 ↗
9. 10.1038/nn.390510.1038/nn.3905 ↗
10. 10.1109/TBME.2004.82668010.1109/TBME.2004.826680 ↗
11. 10.1038/nnano.2015.11510.1038/nnano.2015.115 ↗
12. 10.1016/j.conb.2017.11.00710.1016/j.conb.2017.11.007 ↗
13. Heenricher M. M. · 2004 · 8
14. 10.1038/nn123310.1038/nn1233 ↗
15. 10.1038/nn.426810.1038/nn.4268 ↗
16. 10.1002/adhm.20190055810.1002/adhm.201900558 ↗
17. 10.1021/acs.nanolett.6b0267310.1021/acs.nanolett.6b02673 ↗
18. 10.1088/1741-2552/ab703010.1088/1741-2552/ab7030 ↗
19. 10.1016/j.jneumeth.2005.08.01510.1016/j.jneumeth.2005.08.015 ↗
20. 10.1016/j.neuron.2016.10.02010.1016/j.neuron.2016.10.020 ↗
21. 10.1016/j.jneumeth.2008.12.02410.1016/j.jneumeth.2008.12.024 ↗
22. Xia, Z.; Arias-Gil, G.; Deckert, M.; Vollmer, M.; Curran, A.; Herrera-Molina, R.; Brosch, M.; Krug, K.; Schmidt, B.; Ohl, F. W. Electrochemical Roughening and Carbon Nanotube Coating of Tetrodes for Chronic Single-Unit Recording. bioRxiv 2019, 738245.10.1101/738245 ↗
23. 10.1126/science.aao347410.1126/science.aao3474 ↗
24. 10.1088/1741-2552/ab77f910.1088/1741-2552/ab77f9 ↗
25. 10.1016/j.tibtech.2016.06.00710.1016/j.tibtech.2016.06.007 ↗
26. 10.1016/0022-0728(95)04156-810.1016/0022-0728(95)04156-8 ↗
27. 10.1109/TNSRE.2007.90981110.1109/TNSRE.2007.909811 ↗
28. 10.1016/j.actbio.2014.04.00410.1016/j.actbio.2014.04.004 ↗
29. 10.1021/la800333g10.1021/la800333g ↗
30. 10.1002/admi.20200067510.1002/admi.202000675 ↗
31. 10.1021/acsami.9b0308810.1021/acsami.9b03088 ↗
32. 10.1002/adhm.20190076510.1002/adhm.201900765 ↗
33. 10.1002/jbm.a.3494510.1002/jbm.a.34945 ↗
34. 10.1016/S0022-0728(00)00206-010.1016/S0022-0728(00)00206-0 ↗
35. 10.1002/adfm.20170032910.1002/adfm.201700329 ↗
36. 10.1016/j.synthmet.2008.10.01410.1016/j.synthmet.2008.10.014 ↗
37. 10.1016/S0013-4686(03)00143-910.1016/S0013-4686(03)00143-9 ↗
38. 10.1016/j.biomaterials.2011.04.05110.1016/j.biomaterials.2011.04.051 ↗
39. 10.1039/D1TC00625H10.1039/D1TC00625H ↗
40. 10.1016/j.biomaterials.2012.05.01710.1016/j.biomaterials.2012.05.017 ↗
41. 10.1021/acsapm.3c0086110.1021/acsapm.3c00861 ↗
42. 10.1039/c2an16174e10.1039/c2an16174e ↗
43. Bard, A. J.; Faulkner, L. R. Electrochemical Methods: Fundamentals and Applications, 2nd ed. John Wiley & Sons, 2000; pp 331–367.
44. Lopes-dos-Santos, V.; Brizee, D.; Dupret, D. Spatio-temporal organization of network activity patterns in the hippocampus. bioRxiv 2023, 2023.10.2017.562689.10.1101/2023.10.17.562689 ↗
45. 10.1016/j.jelechem.2010.12.01110.1016/j.jelechem.2010.12.011 ↗
46. 10.1038/s41596-020-0389-210.1038/s41596-020-0389-2 ↗
47. 10.1126/sciadv.140025110.1126/sciadv.1400251 ↗
48. 10.1080/10739149.2015.103856110.1080/10739149.2015.1038561 ↗