journal article·2024-04-10Open access

Sandwich Immuno-RCA Assay with Single Molecule Counting Readout: The Importance of Biointerface Design

Katharina Schmidt, Tomas Riedel, Andres de los Santos Pereira, N. Scott Lynn, Diego Fernando Dorado Daza, Jakub Dostalek

ACS Applied Materials & Interfaces· Volume 16· Issue 14

Abstract

The analysis of low-abundance protein molecules in human serum is reported based on counting of the individual affinity-captured analyte on a solid sensor surface, yielding a readout format similar to digital assays. In this approach, a sandwich immunoassay with rolling circle amplification (RCA) is used for single molecule detection (SMD) through associating the target analyte with spatially distinct bright spots observed by fluorescence microscopy. The unspecific interaction of the target analyte and other immunoassay constituents with the sensor surface is of particular interest in this work, as it ultimately limits the performance of this assay. It is minimized by the design of the respective biointerface and thiol self-assembled monolayer with oligoethylene (OEG) head groups, and a poly[oligo(ethylene glycol) methacrylate] (pHOEGMA) antifouling polymer brush was used for the immobilization of the capture antibody (cAb) on the sensor surface. The assay relying on fluorescent postlabeling of long single-stranded DNA that are grafted from the detection antibody (dAb) by RCA was established with the help of combined surface plasmon resonance and surface plasmon-enhanced fluorescence monitoring of reaction kinetics. These techniques were employed for in situ measurements of conjugating of cAb to the sensor surface, tagging of short single-stranded DNA to dAb, affinity capture of the target analyte from the analyzed liquid sample, and the fluorescence readout of the RCA product. Through mitigation of adsorption of nontarget molecules on the sensor surface by tailoring of the antifouling biointerface, optimizing conjugation chemistry, and by implementing weak Coulombic repelling between dAb and the sensor surface, the limit of detection (LOD) of the assay was substantially improved. For the chosen interleukin-6 biomarker, SMD assay with LOD at a concentration of 4.3 fM was achieved for model (spiked) samples, and validation of the ability of detection of standard human serum samples is demonstrated.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advanced biosensing and bioanalysis techniques · Biosensors and Analytical Detection · Advanced Biosensing Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Laboratory for Life Sciences and Technology (LiST), Danube Private University, Viktor-Kaplan-Straße 2, 2700 Wiener, Neustadt, Austria

Institute of Macromolecular Chemistry, Czech Academy of Sciences, Heyrovského nám. 2, Prague 162 00, Czech Republic

FZU-Institute of Physics, Czech Academy of Sciences, Na Slovance 2, Prague 182 21, Czech Republic

Funding

Austrian Science Fund · Grantov? Agentura Cesk? Republiky · Gesellschaft f?r Forschungsf?rderung Nieder?sterreich

References (25)

Show source-provided references
1. 10.1186/s12916-022-02681-x10.1186/s12916-022-02681-x ↗
2. 10.1186/s12943-022-01543-710.1186/s12943-022-01543-7 ↗
3. 10.1021/acs.analchem.6b0429010.1021/acs.analchem.6b04290 ↗
4. 10.1002/anie.20191392410.1002/anie.201913924 ↗
5. 10.1039/D1CS00137J10.1039/D1CS00137J ↗
6. 10.1038/nbt107210.1038/nbt1072 ↗
7. 10.1021/ac202028g10.1021/ac202028g ↗
8. 10.1073/pnas.17023719710.1073/pnas.170237197 ↗
9. 10.1021/acssensors.7b0038210.1021/acssensors.7b00382 ↗
10. 10.1021/acs.analchem.7b0354210.1021/acs.analchem.7b03542 ↗
11. 10.1021/acs.analchem.2c0567010.1021/acs.analchem.2c05670 ↗
12. 10.1016/j.bios.2013.07.01510.1016/j.bios.2013.07.015 ↗
13. 10.1021/acsami.1c1693010.1021/acsami.1c16930 ↗
14. 10.1016/j.talanta.2020.12148310.1016/j.talanta.2020.121483 ↗
15. 10.1021/acs.analchem.6b0473110.1021/acs.analchem.6b04731 ↗
16. 10.1021/acsami.2c1450010.1021/acsami.2c14500 ↗
17. 10.1021/la011365f10.1021/la011365f ↗
18. 10.1016/j.snb.2014.06.07510.1016/j.snb.2014.06.075 ↗
19. 10.1021/acsami.1c0371510.1021/acsami.1c03715 ↗
20. 10.1021/cr068107d10.1021/cr068107d ↗
21. 10.1021/acs.macromol.7b0008810.1021/acs.macromol.7b00088 ↗
22. 10.1021/mp500233410.1021/mp5002334 ↗
23. 10.1080/19420862.2021.199376810.1080/19420862.2021.1993768 ↗
24. 10.1002/admi.20220121010.1002/admi.202201210 ↗
25. 10.1038/nbt.164110.1038/nbt.1641 ↗