Toward an Electronic Tongue Based on Surfactant-Stabilized Chemosensory Microparticles with a Dual Detection Mode
Source abstract
Abstract
We propose a novel type of electronic tongue based on four types of monodispersed chemosensory microparticles (MPs) with a lipophilic core stabilized by a nonionic poloxamer surfactant. The lipophilic core composition was designed to achieve cross-sensitivity toward various ions and to enable spectrophotometric and/or spectrofluorimetric detection. Thus, generic anion-selective MPs, generic cation-selective MPs, as well as two types of metalloporphyrin-based MPs were fabricated and their morphology was characterized. Next, their differential sensing ability toward the discrimination of five l-tyrosine derivatives (dopamine, 3,4-dihydroxyphenylacetic acid, 3,4-dihydroxy-l-phenylalanine, normetanephrine, 4-hydroxy-3-methoxymandelic acid) was assessed. Comparison with the respective ion-selective electrode (ISE) responses was also provided to verify if the results from the potentiometric e-tongue correspond to outputs of the developed MP optode array. The recognition of dietary supplements containing l-tyrosine (l-Tyr) derivatives with the use of the MP-based e-tongue proved the potential of the developed sensing assay in pharmaceutical analysis.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advanced Chemical Sensor Technologies · Analytical Chemistry and Sensors · Analytical Chemistry and Chromatography
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Chair of Medical Biotechnology, Faculty of Chemistry, Warsaw University of Technology, Noakowskiego 3, 00-664Warsaw, Poland
Funding
Narodowe Centrum Nauki · IDUB project
References (45)
Show source-provided references
1. 10.1021/cr500552410.1021/cr5005524 ↗
2. 10.1021/acs.chemrev.8b0022610.1021/acs.chemrev.8b00226 ↗
3. 10.1039/c3cs60136f10.1039/c3cs60136f ↗
4. 10.1016/S0950-3293(02)00017-410.1016/S0950-3293(02)00017-4 ↗
5. 10.1016/J.TALANTA.2005.12.02910.1016/J.TALANTA.2005.12.029 ↗
6. 10.3390/chemosensors1001000210.3390/chemosensors10010002 ↗
7. 10.3390/s11050468810.3390/s110504688 ↗
8. 10.1016/J.SNB.2007.07.01510.1016/J.SNB.2007.07.015 ↗
9. 10.1016/J.SNB.2006.04.05110.1016/J.SNB.2006.04.051 ↗
10. 10.1016/S0925-4005(99)00316-010.1016/S0925-4005(99)00316-0 ↗
11. 10.1021/acsomega.8b0040310.1021/acsomega.8b00403 ↗
12. 10.1142/9789812833532_006510.1142/9789812833532_0065 ↗
13. 10.1021/acs.chemrev.6b0036110.1021/acs.chemrev.6b00361 ↗
14. Pietrzak M. · 2017 · 36 · 95
15. 10.1002/elan.20030281410.1002/elan.200302814 ↗
16. 10.1016/S0003-2670(00)81776-610.1016/S0003-2670(00)81776-6 ↗
17. 10.1002/hlca.1986069041110.1002/hlca.19860690411 ↗
18. 10.1016/S0022-0728(99)00151-510.1016/S0022-0728(99)00151-5 ↗
19. 10.1002/hlca.1990073052810.1002/hlca.19900730528 ↗
20. 10.3390/s10100885010.3390/s101008850 ↗
21. 10.1016/0003-2670(95)00580-310.1016/0003-2670(95)00580-3 ↗
22. 10.1016/j.talanta.2011.06.02210.1016/j.talanta.2011.06.022 ↗
23. 10.1016/S0022-0728(01)00615-510.1016/S0022-0728(01)00615-5 ↗
24. 10.1021/ac049592k10.1021/ac049592k ↗
25. 10.1016/j.aca.2009.04.01310.1016/j.aca.2009.04.013 ↗
26. 10.1007/s00542-011-1412-x10.1007/s00542-011-1412-x ↗
27. 10.3390/s2116564510.3390/s21165645 ↗
28. 10.3390/s13111575810.3390/s131115758 ↗
29. 10.1039/c000954g10.1039/c000954g ↗
30. 10.1016/j.snb.2013.04.09410.1016/j.snb.2013.04.094 ↗
31. 10.1021/ac402564m10.1021/ac402564m ↗
32. Kalinowska, A.; Matusiak, P.; Skorupska, S.; Grabowska-Jadach, I.; Ciosek-Skibińska, P. In Influence of the Type and Amount of Plasticizer on the Sensory Properties of Microspheres Sensitive to Lipophilic Ions. Proceedings of the CSAC2021: 1st International Electronic Conference on Chemical Sensors and Analytical Chemistry; 2021; pp 1–6.10.3390/CSAC2021-10487 ↗
33. Kalinowska, A.; Skorupska, S.; Grabowska-jadach, I.; Ciosek-Skibińska, P. In The Use of Ultrasounds in the Preparation of Chemosensory, Engineering Proceedings; 2021; pp 1–6.10.3390/ecsa-8-11294 ↗
34. 10.1016/j.talanta.2016.10.01810.1016/j.talanta.2016.10.018 ↗
35. 10.1016/J.SNB.2016.06.14710.1016/J.SNB.2016.06.147 ↗
36. 10.3390/s1609135310.3390/s16091353 ↗
37. 10.1016/J.CHEMOLAB.2017.05.00310.1016/J.CHEMOLAB.2017.05.003 ↗
38. 10.1016/J.SNB.2018.05.13710.1016/J.SNB.2018.05.137 ↗
39. 10.1016/J.ACA.2014.03.03310.1016/J.ACA.2014.03.033 ↗
40. 10.1016/S0003-2670(02)00635-910.1016/S0003-2670(02)00635-9 ↗
41. 10.1016/J.JELECHEM.2018.12.02410.1016/J.JELECHEM.2018.12.024 ↗
42. 10.1016/J.TALANTA.2011.07.04110.1016/J.TALANTA.2011.07.041 ↗
43. 10.1016/J.COLSURFA.2012.06.04510.1016/J.COLSURFA.2012.06.045 ↗
44. 10.1016/J.ELECTACTA.2011.04.07010.1016/J.ELECTACTA.2011.04.070 ↗
45. 10.1007/BF0058213310.1007/BF00582133 ↗