Focused Ion Beam (FIB) Milling Damage Formed During Tem Sample Preparation of Silicon
Source abstract
Abstract
Abstract The ongoing reduction of scale of semiconductor device structures places increasing demands on the sample preparation methods used for transmission electron microscopy (TEM). Much of the semiconductor industry's failure analysis and new process development effort requires specific transistor, metal or dielectric structures to be analyzed using TEM techniques. Focused ion beam (FIB) milling has emerged as a valuable technique for site-specific TEM sample preparation. FIB milling, typically with 25-50kV Ga+ ions, enables thin TEM samples to be prepared with submicron precision. However, Ga+ ion milling significantly modifies the surfaces of TEM samples by implantation and amorphization. Previous work using 90° milling angles has shown that Ga+ ion milling of Si produces a surface damage layer that is 280Å thick. This damage is problematical since the current generation of semiconductor devices requires TEM samples in the 500-1000Å thickness range.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Integrated Circuits and Semiconductor Failure Analysis · Electron and X-Ray Spectroscopy Techniques · Ion-surface interactions and analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Materials Technology Department, Intel Corporation , Santa Clara, CA 95052
Dept.of Materials Science and Engineering, Northwestern University , Evanston, IL 60208
References (1)
Show source-provided references
1. Basile · Proc. Mat. Res. Soc. Symp. · 1992 · 23 · 254