Highly Reproducible Secondary Electron Imaging under Electron Irradiation Using High-Pass Energy Filtering in Low-Voltage Scanning Electron Microscopy
Source abstract
Abstract
Abstract The reproducibility of contrast in secondary electron (SE) imaging during continuous electron irradiation, which caused surface contamination, was investigated using SE high-pass energy filtering in low-voltage scanning electron microscopy (SEM). According to high-pass energy-filtered imaging, dopant contrast in an indium phosphide remained remarkably stable during continuous electron irradiation although the contrast in unfiltered SE images decreased rapidly as a contamination layer was formed. Charge neutralization and the SE energy distributions indicate that the contamination layer induces a positive charge. This results in a decrease of low-energy SE emissions and reduced dopant contrast in unfiltered SE images. The retention of contrast was also observed in high-pass energy-filtered images of a gold surface. These results suggest that this imaging method can be widely used when SE intensities decrease under continuous electron irradiation in unfiltered SE images. Thus, high-pass energy-filtered SE imaging will be of a great assistance for SEM users in the reproducibility of contrast such as a quantitative dopant mapping in semiconductors.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electron and X-Ray Spectroscopy Techniques · Advanced Electron Microscopy Techniques and Applications · Integrated Circuits and Semiconductor Failure Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (21)
Show source-provided references
1. 10.1063/1.303980410.1063/1.3039804 ↗
2. Solid surface observation at very low accelerating voltage (200V–1kV) by scanning electron microscope
3. 10.1063/1.33284010.1063/1.332840 ↗
4. 10.1063/1.152586210.1063/1.1525862 ↗
5. 10.1117/3.226507410.1117/3.2265074 ↗
6. Influence of incident electron energy on specimen contamination in SEM mode
7. 10.1016/S0304-3991(02)00279-610.1016/S0304-3991(02)00279-6 ↗
8. 10.1088/1742-6596/241/1/01207810.1088/1742-6596/241/1/012078 ↗
9. 10.1063/1.147696810.1063/1.1476968 ↗
10. 10.1002/sia.210810.1002/sia.2108 ↗
11. 10.1017/S143192760909040010.1017/S1431927609090400 ↗
12. 10.1016/0038-1101(67)90099-810.1016/0038-1101(67)90099-8 ↗
13. 10.1093/oxfordjournals.jmicro.a02381110.1093/oxfordjournals.jmicro.a023811 ↗
14. 10.1063/1.12383210.1063/1.123832 ↗
15. 10.1116/1.58981110.1116/1.589811 ↗
16. 10.1016/j.ultramic.2010.04.00810.1016/j.ultramic.2010.04.008 ↗
17. 10.1063/1.141504510.1063/1.1415045 ↗
18. 10.1016/S0167-9317(04)00249-710.1016/S0167-9317(04)00249-7 ↗
19. 10.1063/1.11704110.1063/1.117041 ↗
20. 10.1093/jmicro/dfq04610.1093/jmicro/dfq046 ↗
21. 10.1063/1.233598010.1063/1.2335980 ↗