journal article·2024-05-15

Biolayer-Interferometry-Guided Functionalization of Screen-Printed Graphene for Label-Free Electrochemical Virus Detection

Beata M. Szydlowska, Cícero C. Pola, Zizhen Cai, Lindsay E. Chaney, Janan Hui, Robert Sheets, Jeremiah Carpenter, Delphine Dean, Jonathan C. Claussen, Carmen L. Gomes, Mark C. Hersam

ACS Applied Materials & Interfaces· Volume 16· Issue 19
Publisher page

Abstract

Additive manufacturing holds promise for rapid prototyping and low-cost production of biosensors for diverse pathogens. Among additive manufacturing methods, screen printing is particularly desirable for high-throughput production of sensing platforms. However, this technique needs to be combined with carefully formulated inks, rapid postprocessing, and selective functionalization to meet all requirements for high-performance biosensing applications. Here, we present screen-printed graphene electrodes that are processed with thermal annealing to achieve high surface area and electrical conductivity for sensitive biodetection via electrochemical impedance spectroscopy. As a proof-of-concept, this biosensing platform is utilized for electrochemical detection of SARS-CoV-2. To ensure reliable specificity in the presence of multiple variants, biolayer interferometry (BLI) is used as a label-free and dynamic screening method to identify optimal antibodies for concurrent affinity to the Spike S1 proteins of Delta, Omicron, and Wild Type SARS-CoV-2 variants while maintaining low affinity to competing pathogens such as Influenza H1N1. The BLI-identified antibodies are robustly bound to the graphene electrode surface via oxygen moieties that are introduced during the thermal annealing process. The resulting electrochemical immunosensors achieve superior metrics including rapid detection (55 s readout following 15 min of incubation), low limits of detection (approaching 500 ag/mL for the Omicron variant), and high selectivity toward multiple variants. Importantly, the sensors perform well on clinical saliva samples detecting as few as 10 3 copies/mL of SARS-CoV-2 Omicron, following CDC protocols. The combination of the screen-printed graphene sensing platform and effective antibody selection using BLI can be generalized to a wide range of point-of-care immunosensors.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: SARS-CoV-2 detection and testing · Advanced biosensing and bioanalysis techniques · Biosensors and Analytical Detection

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Materials Science and Engineering, Northwestern University, Evanston, Illinois 60208, United States

Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, United States

Department of Chemistry, Northwestern University, Evanston, Illinois 60208, United States

Center for Innovative Medical Devices and Sensors (REDDI Lab), Clemson University, Clemson, South Carolina 29634, United States

Department of Bioengineering, Clemson University, Clemson, South Carolina 29634, United States

Department of Electrical and Computer Engineering, Northwestern University, Evanston, Illinois 60208, United States

Funding

Centers for Disease Control and Prevention · National Institute of Standards and Technology · Deutsche Forschungsgemeinschaft · National Institutes of Health · National Science Foundation

References (75)

Show source-provided references
1. 10.1038/nrmicro.2016.8110.1038/nrmicro.2016.81 ↗
2. WHO Coronavirus (COVID-19) Dashboard, 2023. https://covid19.who.int/ (accessed 2022-10-03).
3. WHO Coronavirus (COVID-19) Dashboard - Vaccination, 2023. https://covid19.who.int/?mapFilter=vaccinations (accessed 2022-10-03).
4. 10.1016/S0140-6736(21)00370-610.1016/S0140-6736(21)00370-6 ↗
5. 10.1089/pop.2021.021410.1089/pop.2021.0214 ↗
6. 10.1016/j.bios.2021.11304610.1016/j.bios.2021.113046 ↗
7. CDC 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel. 2020. https://www.fda.gov/media/134922/download (accessed 2022-10-03).
8. 10.1016/j.bios.2020.11227410.1016/j.bios.2020.112274 ↗
9. 10.1016/j.jcv.2020.10461210.1016/j.jcv.2020.104612 ↗
10. 10.1021/acssensors.0c0262110.1021/acssensors.0c02621 ↗
11. 10.1021/acsnano.1c0118810.1021/acsnano.1c01188 ↗
12. 10.1038/s41598-022-22249-210.1038/s41598-022-22249-2 ↗
13. 10.1021/acsnano.0c0262410.1021/acsnano.0c02624 ↗
14. 10.1021/acsnano.0c0282310.1021/acsnano.0c02823 ↗
15. 10.1016/j.bios.2020.11234910.1016/j.bios.2020.112349 ↗
16. 10.1021/acsnano.0c0565710.1021/acsnano.0c05657 ↗
17. 10.3389/fpls.2020.59810310.3389/fpls.2020.598103 ↗
18. 10.1016/j.sbsr.2022.10054010.1016/j.sbsr.2022.100540 ↗
19. 10.1002/adfm.20220706510.1002/adfm.202207065 ↗
20. 10.1016/j.scs.2021.10304610.1016/j.scs.2021.103046 ↗
21. 10.1016/j.mtchem.2020.10038510.1016/j.mtchem.2020.100385 ↗
22. 10.1088/2053-1583/ab29b210.1088/2053-1583/ab29b2 ↗
23. 10.1088/2053-1583/ac733910.1088/2053-1583/ac7339 ↗
24. 10.1039/D1CP04831G10.1039/D1CP04831G ↗
25. 10.1016/j.jechem.2021.08.01110.1016/j.jechem.2021.08.011 ↗
26. 10.1002/adma.20200664710.1002/adma.202006647 ↗
27. 10.1007/s10853-020-05499-110.1007/s10853-020-05499-1 ↗
28. 10.1021/acsnano.5b0117910.1021/acsnano.5b01179 ↗
29. 10.1038/s41578-020-00234-310.1038/s41578-020-00234-3 ↗
30. 10.1002/admt.20210112110.1002/admt.202101121 ↗
31. 10.1016/j.talanta.2018.08.06510.1016/j.talanta.2018.08.065 ↗
32. 10.1149/2754-2734/acb83210.1149/2754-2734/acb832 ↗
33. 10.1016/j.cossms.2023.10112110.1016/j.cossms.2023.101121 ↗
34. 10.1007/s00604-021-04762-910.1007/s00604-021-04762-9 ↗
35. 10.3390/bios1208059310.3390/bios12080593 ↗
36. 10.1016/j.scitotenv.2022.16070010.1016/j.scitotenv.2022.160700 ↗
37. 10.1016/j.electacta.2021.13958110.1016/j.electacta.2021.139581 ↗
38. 10.1016/j.bios.2022.11420910.1016/j.bios.2022.114209 ↗
39. 10.3390/nano1203041510.3390/nano12030415 ↗
40. 10.1016/j.aca.2022.34012010.1016/j.aca.2022.340120 ↗
41. 10.1016/j.aca.2021.33937210.1016/j.aca.2021.339372 ↗
42. 10.1039/D0TC03309J10.1039/D0TC03309J ↗
43. 10.1021/acsami.9b0458910.1021/acsami.9b04589 ↗
44. 10.1016/j.talo.2021.10003210.1016/j.talo.2021.100032 ↗
45. Wang J. · 2023
46. 10.1021/acs.jchemed.7b0036110.1021/acs.jchemed.7b00361 ↗
47. 10.3390/s2119657810.3390/s21196578 ↗
48. 10.1016/j.bios.2016.07.02410.1016/j.bios.2016.07.024 ↗
49. 10.1021/acsmeasuresciau.2c0007010.1021/acsmeasuresciau.2c00070 ↗
50. 10.1021/ac60230a01610.1021/ac60230a016 ↗
51. 10.1021/acs.chemmater.7b0002910.1021/acs.chemmater.7b00029 ↗
52. 10.1088/2053-1583/ab891910.1088/2053-1583/ab8919 ↗
53. Barsoukov E. · 200510.1002/0471716243 ↗
54. 10.1039/c3ay26476a10.1039/c3ay26476a ↗
55. 10.3390/s2119657810.3390/s21196578 ↗
56. Bard A. J. · 2000
57. 10.1016/j.jelechem.2016.05.04910.1016/j.jelechem.2016.05.049 ↗
58. 10.1016/j.matt.2021.05.00310.1016/j.matt.2021.05.003 ↗
59. 10.1007/s00604-022-05288-410.1007/s00604-022-05288-4 ↗
60. 10.1016/j.bios.2020.11268610.1016/j.bios.2020.112686 ↗
61. 10.1016/j.talanta.2022.12321110.1016/j.talanta.2022.123211 ↗
62. 10.3390/bios1206042610.3390/bios12060426 ↗
63. 10.1021/acssensors.1c0161410.1021/acssensors.1c01614 ↗
64. WHO. COVID-19 Target product profiles for priority diagnostics to support response to the COVID-19 Pandemic v.1.0. World Health Organization. R&D Blueprint, 2020.
65. 10.1128/JCM.02880-2010.1128/JCM.02880-20 ↗
66. 10.1136/bmj-2021-06687110.1136/bmj-2021-066871 ↗
67. Joshua M. D. · MedRxiv · 2021 · 2021
68. 10.1128/jcm.00140-2210.1128/jcm.00140-22 ↗
69. CDC. CDC 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel. 2023, CDC-006-00019.
70. 10.3791/63395-v10.3791/63395-v ↗
71. 10.1016/S2352-4642(21)00060-210.1016/S2352-4642(21)00060-2 ↗
72. 10.1021/acsestwater.2c0010510.1021/acsestwater.2c00105 ↗
73. 10.1128/spectrum.00797-2210.1128/spectrum.00797-22 ↗
74. 10.3389/fpubh.2022.85842110.3389/fpubh.2022.858421 ↗
75. McNaught A. D. · 1997