Paper-Based Ionic Thermocouples for Inexpensive and High-Precision Measurement of Temperature
Source abstract
Abstract
Accurate and yet cost-effective temperature measurements are required in various sectors of academia and industry. Thermocouples (TCs) are most widely used for temperature measurements; however, their low temperature sensitivity and high thermal conductivity should be improved to ensure the reliable measurement of output voltage for small temperature differences. To address this, a paper-based ionic thermocouple (P-iTC) presented here utilizes a pair of paper strips soaked with the electrolytes of potassium ferri-/ferrocyanide and iron (II/III) chloride redox couples, which are used as p- and n-type elements, respectively. The fabricated P-iTC provides 70× higher temperature sensitivity (α, 2.8 mV/K) and 30× lower thermal conductivity (k, 0.8 W/m K) than those of commercial K-type TCs, thereby yielding a remarkably high α/k ratio of 3.5 mV m/W. Reliable sensing performance is measured during three weeks of operation, which indicates that the P-iTC should be stable in long-term operation. To demonstrate the practicality of the P-iTC, a 3 × 3 planar array of P-iTCs is fabricated to monitor the temperature profile of a surface in contact with heat sources. Using pencil-drawn graphite electrodes on paper, a highly cost-effective P-iTC with the material cost of ∼0.5 cents per device is also fabricated, which is successfully used to monitor cold chain temperatures while retaining its excellent temperature-sensing performance.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Gas Sensing Nanomaterials and Sensors · Electrical and Thermal Properties of Materials · Advanced Thermoelectric Materials and Devices
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical Engineering, Inha University, 100 Inha-ro, Michuhol-gu, Incheon 22212, Republic of Korea
Funding
National Research Foundation of Korea · Korea Institute of Energy Technology Evaluation and Planning
References (50)
Show source-provided references
1. 10.1021/ac00217a00210.1021/ac00217a002 ↗
2. 10.1021/ac60203a01310.1021/ac60203a013 ↗
3. 10.1038/2121229a010.1038/2121229a0 ↗
4. 10.1016/0040-6031(76)80056-110.1016/0040-6031(76)80056-1 ↗
5. 10.1038/nmat375510.1038/nmat3755 ↗
6. 10.1002/adma.20210257510.1002/adma.202102575 ↗
7. Kasap S. · 2001
8. 10.1002/adfm.20200057410.1002/adfm.202000574 ↗
9. Powell, R. L. Thermocouple Reference Tables Based on the IPTS-68, US National Bureau of Standards: 1974; Vol. 125.10.6028/NBS.MONO.125 ↗
10. 10.1063/1.35188510.1063/1.351885 ↗
11. 10.1038/s41467-019-08930-710.1038/s41467-019-08930-7 ↗
12. 10.4037/ajcc2007.16.5.48510.4037/ajcc2007.16.5.485 ↗
13. 10.1016/j.ijthermalsci.2008.06.01510.1016/j.ijthermalsci.2008.06.015 ↗
14. 10.1007/s00425005008710.1007/s004250050087 ↗
15. 10.1007/s11119-016-9470-910.1007/s11119-016-9470-9 ↗
16. 10.1016/j.apenergy.2020.11525510.1016/j.apenergy.2020.115255 ↗
17. Blaha, D. M.; Thermocouple Measurement Circuit. US 8 104 956, 2012.
18. Duff M. · Analog dialogue · 2010 · 44 · 1
19. 10.1016/j.joule.2021.02.00910.1016/j.joule.2021.02.009 ↗
20. 10.1021/nl903267n10.1021/nl903267n ↗
21. 10.1038/ncomms1060010.1038/ncomms10600 ↗
22. 10.1149/1.204844610.1149/1.2048446 ↗
23. 10.1002/adma.20160565210.1002/adma.201605652 ↗
24. 10.1016/j.mattod.2021.02.01610.1016/j.mattod.2021.02.016 ↗
25. 10.1016/j.pmatsci.2021.10084010.1016/j.pmatsci.2021.100840 ↗
26. 10.1039/D1TA00820J10.1039/D1TA00820J ↗
27. 10.1039/D1MH00775K10.1039/D1MH00775K ↗
28. 10.1039/C7TA11146K10.1039/C7TA11146K ↗
29. 10.1002/aenm.20190108510.1002/aenm.201901085 ↗
30. 10.1063/1.492319910.1063/1.4923199 ↗
31. 10.1126/science.aaz504510.1126/science.aaz5045 ↗
32. 10.1038/s41563-019-0315-610.1038/s41563-019-0315-6 ↗
33. 10.1038/s41467-018-07625-910.1038/s41467-018-07625-9 ↗
34. 10.1016/j.nanoen.2016.11.01410.1016/j.nanoen.2016.11.014 ↗
35. 10.1126/science.abd674910.1126/science.abd6749 ↗
36. 10.1039/TF957530016710.1039/TF9575300167 ↗
37. 10.1021/ja01389a00810.1021/ja01389a008 ↗
38. 10.1038/s41598-019-45127-w10.1038/s41598-019-45127-w ↗
39. 10.1021/ic00190a04210.1021/ic00190a042 ↗
40. 10.1021/ja00863a00210.1021/ja00863a002 ↗
41. 10.1063/1.174849210.1063/1.1748492 ↗
42. 10.1039/C8CP02512F10.1039/C8CP02512F ↗
43. 10.1115/1.139968010.1115/1.1399680 ↗
44. 10.1080/07373937.2011.63814810.1080/07373937.2011.638148 ↗
45. 10.1007/978-0-387-69002-5_1010.1007/978-0-387-69002-5_10 ↗
46. 10.1021/ac702605a10.1021/ac702605a ↗
47. 10.1039/C5AN00909J10.1039/C5AN00909J ↗
48. 10.1016/j.vaccine.2007.02.05210.1016/j.vaccine.2007.02.052 ↗
49. World Health Organization, and World Health Organization. Department of Immunization. Immunization in Practice: a Practical Guide for Health Staff. World Health Organization, 2015.
50. Xu, X.; Lan, H.; Wang, R. In Identification of Critical Control Points of the Food Cold Chain Logistic Process, 2010 International Conference on Logistics Systems and Intelligent Management (ICLSIM), IEEE: 2010; pp. 164–168.10.1109/ICLSIM.2010.5461444 ↗