journal article·2021-09-15Open access

In Situ Investigation of the Cytotoxic and Interfacial Characteristics of Titanium When Galvanically Coupled with Magnesium Using Scanning Electrochemical Microscopy

Abdelilah Asserghine, Amir M. Ashrafi, Atripan Mukherjee, Frantisek Petrlak, Zbynek Heger, Pavel Svec, Lukas Richtera, Livia Nagy, Ricardo M. Souto, Geza Nagy, Vojtech Adam

ACS Applied Materials & Interfaces· Volume 13· Issue 36

Abstract

Recently, the cytotoxic properties of galvanically coupled Ti-Mg particles have been shown in different cells. This cytotoxic effect has been attributed mainly to Mg due to its tendency to undergo activation when coupled with Ti, forming a galvanic cell consisting of an anode (Mg) and a cathode (Ti). However, the role of the Ti cathode has been ignored in explaining the cytotoxic effect of Ti-Mg particles due to its high resistance to corrosion. In this work, the role of titanium (Ti) in the cytotoxic mechanism of galvanically coupled Ti-Mg particles was examined. A model galvanic cell (MGC) was prepared to simulate the Mg-Ti particles. The electrochemical reactivity of the Ti sample and the pH change in it due to galvanic coupling with Mg were investigated using scanning electrochemical microscopy (SECM). It was observed that the Ti surface changed from passive to electrochemically active when coupled with Mg. Furthermore, after only 15 min of galvanic coupling with Mg, the pH in the electrolyte volume adjacent to the Ti surface increased to an alkaline pH value. The effects of the galvanic coupling of Ti and Mg, as well as those of the alkaline pH environment, on the viability of Hs27 fibroblast cells were investigated. It was shown that the viability of Hs27 cells significantly diminished when Mg and Ti were galvanically coupled compared to when the two metals were electrically disconnected. Thus, although Ti usually exhibited high corrosion resistance when exposed to physiological environments, an electrochemically active surface was observed when galvanically coupled with Mg, and this surface may participate in electron transfer reactions with chemical species in the neighboring environment; this participation resulted in the increased pH values above its surface and enhanced generation of reactive oxygen species. These features contributed to the development of cytotoxic effects by galvanically coupled Ti-Mg particles.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Corrosion Behavior and Inhibition · Titanium Alloys Microstructure and Properties · Magnesium Alloys: Properties and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of General and Physical Chemistry, Faculty of Sciences, University of Pecs, Ifjussg u. 6, Pecs 7624, Hungary

Laboratoire Interfaces et Systemes Electrochimiques (LISE), Sorbonne Universite, CNRS, 4 Place Jussieu, Paris F-75005, France

Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1665/1, Brno 613 00, Czech Republic

Central European Institute of Technology, Brno University of Technology, Purkynova 123, Brno CZ-612 00, Czech Republic

Janos Szentagothai Research Center, University of Pecs, Ifjusag u. 20, Pecs 7624, Hungary

Institute of Material Science and Nanotechnology, University of La Laguna, P.O. Box 456, La Laguna E-38200, Tenerife, Canary Islands, Spain

Funding

European Regional Development Fund · Ministerstvo ??kolstv??, Ml??de??e a T??lov??chovy · Nemzeti Kutat??si Fejleszt??si ??s Innov??ci??s Hivatal

References (42)

Show source-provided references
1. 10.1016/j.pmatsci.2008.06.00410.1016/j.pmatsci.2008.06.004 ↗
2. 10.1016/j.biomaterials.2005.10.00310.1016/j.biomaterials.2005.10.003 ↗
3. 10.1016/j.actbio.2015.11.03010.1016/j.actbio.2015.11.030 ↗
4. 10.1002/jbm.b.3410910.1002/jbm.b.34109 ↗
5. 10.1038/nrmicro302810.1038/nrmicro3028 ↗
6. Thull R. · 1998 · 291
7. Worch H. · 1998 · 177
8. 10.1016/j.elecom.2017.08.01810.1016/j.elecom.2017.08.018 ↗
9. 10.1016/j.elecom.2018.08.00810.1016/j.elecom.2018.08.008 ↗
10. 10.1016/j.elecom.2019.10653910.1016/j.elecom.2019.106539 ↗
11. 10.1016/j.biomaterials.2014.11.01310.1016/j.biomaterials.2014.11.013 ↗
12. 10.5006/235410.5006/2354 ↗
13. 10.1021/acs.chemrev.6b0006710.1021/acs.chemrev.6b00067 ↗
14. 10.5006/148310.5006/1483 ↗
15. 10.1149/2.0701512jes10.1149/2.0701512jes ↗
16. 10.1016/j.snb.2019.12662510.1016/j.snb.2019.126625 ↗
17. 10.1002/elan.20160026510.1002/elan.201600265 ↗
18. 10.1016/j.electacta.2014.11.01210.1016/j.electacta.2014.11.012 ↗
19. 10.1016/j.electacta.2015.02.07910.1016/j.electacta.2015.02.079 ↗
20. 10.1016/j.jelechem.2014.03.00210.1016/j.jelechem.2014.03.002 ↗
21. 10.1016/j.jelechem.2014.10.03010.1016/j.jelechem.2014.10.030 ↗
22. 10.1149/2.001310jes10.1149/2.001310jes ↗
23. 10.1002/adma.20060144610.1002/adma.200601446 ↗
24. 10.1021/cm070023d10.1021/cm070023d ↗
25. 10.1149/1.222089710.1149/1.2220897 ↗
26. 10.1021/acsbiomaterials.7b0024410.1021/acsbiomaterials.7b00244 ↗
27. 10.1016/j.snb.2020.12833910.1016/j.snb.2020.128339 ↗
28. Gilbert, J. L. Electrochemical Coupling of Metallic Biomaterial Implants for Biological Effect. U.S. Patent 9,039,764 B2, 2015.
29. 10.1016/s0956-5663(02)00167-710.1016/s0956-5663(02)00167-7 ↗
30. 10.1021/ac00057a01910.1021/ac00057a019 ↗
31. 10.1016/0013-4686(95)00465-310.1016/0013-4686(95)00465-3 ↗
32. 10.1002/maco.20080512010.1002/maco.200805120 ↗
33. 10.1002/(sici)1097-4636(199603)30:3<393::aid-jbm14>3.0.co;2-l10.1002/(sici)1097-4636(199603)30:3<393::aid-jbm14>3.0.co;2-l ↗
34. 10.1016/j.cossms.2007.08.00410.1016/j.cossms.2007.08.004 ↗
35. 10.1016/j.elecom.2017.03.01110.1016/j.elecom.2017.03.011 ↗
36. 10.1016/j.drup.2004.01.00410.1016/j.drup.2004.01.004 ↗
37. 10.1016/j.biomaterials.2017.01.02810.1016/j.biomaterials.2017.01.028 ↗
38. 10.1038/s41598-020-63007-610.1038/s41598-020-63007-6 ↗
39. 10.1053/j.gastro.2011.02.05410.1053/j.gastro.2011.02.054 ↗
40. Cho K. S. · Invest. Ophthalmol. Vis. Sci. · 1999 · 40 · 911
41. 10.1038/sj.onc.120221110.1038/sj.onc.1202211 ↗
42. 10.1038/srep4192410.1038/srep41924 ↗