journal article·2024-02-28

Multifunctional Siloxene-Decorated Laser-Inscribed Graphene Patch for Sweat Ion Analysis and Electrocardiogram Monitoring

Xue Hui, Md Asaduzzaman, M. Abu Zahed, Sudeep Sharma, SeongHoon Jeong, Hyesu Song, Omar Faruk, Jae Yeong Park

Publisher page

Abstract

Potentiometric detection in complex biological fluids enables continuous electrolyte monitoring for personal healthcare; however, the commercialization of ion-selective electrode-based devices has been limited by the rapid loss of potential stability caused by electrode surface inactivation and biofouling. Here, we describe a simple multifunctional hybrid patch incorporating an Au nanoparticle/siloxene-based solid contact (SC) supported by a substrate made of laser-inscribed graphene on poly(dimethylsiloxane) for the noninvasive detection of sweat Na + and K + . These SC nanocomposites prevent the formation of a water layer during ion-to-electron transfer, preserving 3 and 5 μV/h potential drift for the Na + and K + ion-selective electrodes, respectively, after 13 h of exposure. The lamellar structure of the siloxene sheets increases the SC area. In addition, the electroplated Au nanoparticles, which have a large surface area and excellent conductivity, further increased the electric double-layer capacitance at the interface between the ion-selective membranes and solid-state contacts, thus facilitating ion-to-electron transduction and ultimately improving the detection stability of Na + and K + . Furthermore, the integrated temperature and electrocardiogram sensors in the flexible patch assist in monitoring body temperature and electrocardiogram signals, respectively. Featuring both electrochemical ion-selective and physical sensors, this patch offers immense potential for the self-monitoring of health.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Analytical Chemistry and Sensors · Advanced Sensor and Energy Harvesting Materials · Gas Sensing Nanomaterials and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Electronic Engineering, Kwangwoon University, 447-1 Wolgye-dong, Nowon-gu, Seoul 01897, Republic of Korea

Human IoT Focused Research Center, Kwangwoon University, 447-1 Wolgye-dong, Nowon-gu, Seoul 01897, Republic of Korea

SnE Solution Co., Ltd, 447-1 Wolgye-dong, Nowon-gu, Seoul 01897, Republic of Korea

Funding

National Research Foundation of Korea · Ministry of Trade, Industry and Energy

References (51)

Show source-provided references
1. 10.1021/acs.analchem.9b0212610.1021/acs.analchem.9b02126 ↗
2. 10.1002/smll.20210312510.1002/smll.202103125 ↗
3. 10.1016/j.cobme.2019.01.00310.1016/j.cobme.2019.01.003 ↗
4. 10.1021/acs.analchem.2c0429110.1021/acs.analchem.2c04291 ↗
5. 10.1126/science.125016910.1126/science.1250169 ↗
6. 10.1063/1.492103910.1063/1.4921039 ↗
7. 10.1039/b9ay00184k10.1039/b9ay00184k ↗
8. 10.1016/j.nut.2004.04.01110.1016/j.nut.2004.04.011 ↗
9. 10.1111/j.1469-445X.2000.02058.x10.1111/j.1469-445X.2000.02058.x ↗
10. Thaysen, R. N. H.; York, N. Techniques Employed Permitted. Most, 1955, pp 114–120.
11. 10.1016/0026-265X(67)90014-810.1016/0026-265X(67)90014-8 ↗
12. 10.1039/c3an00346a10.1039/c3an00346a ↗
13. Novell, M.; Parrilla, M.; Crespo, A.; Rius, F. X.; Andrade, F. J. Paper-Based Ion-Selective Potentiometric Sensors. 2012.10.1021/ac202979j ↗
14. 10.1016/j.snb.2010.02.04410.1016/j.snb.2010.02.044 ↗
15. 10.1016/j.electacta.2015.03.00310.1016/j.electacta.2015.03.003 ↗
16. 10.1016/j.bios.2021.11324910.1016/j.bios.2021.113249 ↗
17. 10.1002/elan.20080461210.1002/elan.200804612 ↗
18. 10.1021/acs.estlett.7b0013010.1021/acs.estlett.7b00130 ↗
19. 10.1021/acs.analchem.0c0450610.1021/acs.analchem.0c04506 ↗
20. 10.1021/acs.analchem.6b0462510.1021/acs.analchem.6b04625 ↗
21. 10.1021/ac00116a03410.1021/ac00116a034 ↗
22. 10.1039/an994190198510.1039/an9941901985 ↗
23. 10.1021/ac00045a00710.1021/ac00045a007 ↗
24. 10.1016/j.trac.2015.11.00410.1016/j.trac.2015.11.004 ↗
25. 10.1007/s10008-008-0579-210.1007/s10008-008-0579-2 ↗
26. 10.1021/ac070132b10.1021/ac070132b ↗
27. 10.1021/ac501633r10.1021/ac501633r ↗
28. 10.1021/ac071156l10.1021/ac071156l ↗
29. 10.1016/j.trac.2018.11.02410.1016/j.trac.2018.11.024 ↗
30. 10.1016/j.cej.2023.14583610.1016/j.cej.2023.145836 ↗
31. 10.1002/adma.20170221110.1002/adma.201702211 ↗
32. 10.1021/acs.accounts.8b0008410.1021/acs.accounts.8b00084 ↗
33. 10.1016/j.bios.2022.11484610.1016/j.bios.2022.114846 ↗
34. 10.1016/j.nanoen.2020.10571110.1016/j.nanoen.2020.105711 ↗
35. 10.1039/c9ta03584b10.1039/c9ta03584b ↗
36. 10.1016/j.cej.2020.12468410.1016/j.cej.2020.124684 ↗
37. 10.1039/C8EE00160J10.1039/C8EE00160J ↗
38. 10.1039/b500758e10.1039/b500758e ↗
39. 10.1016/j.aca.2017.02.00410.1016/j.aca.2017.02.004 ↗
40. 10.1021/acs.analchem.7b0156010.1021/acs.analchem.7b01560 ↗
41. 10.1016/j.electacta.2016.11.06910.1016/j.electacta.2016.11.069 ↗
42. 10.4103/ijcep.ijcep_43_1710.4103/ijcep.ijcep_43_17 ↗
43. 10.1038/srep4249210.1038/srep42492 ↗
44. Severi S. · Comput. Cardiol. · 2009 · 36 · 821
45. 10.1002/smll.20220124710.1002/smll.202201247 ↗
46. 10.1016/j.enzmictec.2016.08.00610.1016/j.enzmictec.2016.08.006 ↗
47. 10.1038/s41467-020-15808-610.1038/s41467-020-15808-6 ↗
48. 10.1016/j.bios.2020.11284410.1016/j.bios.2020.112844 ↗
49. 10.1021/ac991146n10.1021/ac991146n ↗
50. 10.1002/1521-4109(200011)12:16<1286::AID-ELAN1286>3.0.CO;2-Q10.1002/1521-4109(200011)12:16<1286::AID-ELAN1286>3.0.CO;2-Q ↗
51. 10.1039/C5RA00871A10.1039/C5RA00871A ↗