Bioresorbable passive resonance sensors based on inductor-capacitor (LC) circuits provide an auspicious sensing technology for temporary battery-free implant applications due to their simplicity, wireless readout, and the ability to be eventually metabolized by the body. In this study, the fabrication and performance of various LC circuit-based sensors are investigated to provide a comprehensive view on different material options and fabrication methods. The study is divided into sections that address different sensor constituents, including bioresorbable polymer and bioactive glass substrates, dissolvable metallic conductors, and atomic layer deposited (ALD) water barrier films on polymeric substrates. The manufactured devices included a polymer-based pressure sensor that remained pressure responsive for 10 days in aqueous conditions, the first wirelessly readable bioactive glass-based resonance sensor for monitoring the complex permittivity of its surroundings, and a solenoidal coil-based compression sensor built onto a polymeric bone fixation screw. The findings together with the envisioned orthopedic applications provide a reference point for future studies related to bioresorbable passive resonance sensors.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
BioMediTech, Faculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu 3, Tampere 33720, Finland
Materials Science and Environmental Engineering, Faculty of Engineering and Natural Sciences, Tampere University, Korkeakoulunkatu 6, Tampere 33720, Finland
Department of Chemistry, University of Colorado Boulder, Boulder, Colorado 80309, United States
Funding
Suomen Kulttuurirahasto · Business Finland
References (77)
Show source-provided references
1. 10.5435/JAAOS-20-06-38310.5435/JAAOS-20-06-383 ↗
2. 10.1098/rsta.2011.043910.1098/rsta.2011.0439 ↗
3. 10.1038/s41551-018-0336-510.1038/s41551-018-0336-5 ↗
4. 10.2147/IEH.S13351810.2147/IEH.S133518 ↗
5. 10.1016/j.bioactmat.2017.12.00110.1016/j.bioactmat.2017.12.001 ↗
6. 10.1002/advs.20190287210.1002/advs.201902872 ↗
7. 10.1109/JMEMS.2016.260229810.1109/JMEMS.2016.2602298 ↗
8. 10.1109/JSEN.2017.278022610.1109/JSEN.2017.2780226 ↗
9. 10.1038/s41928-018-0071-710.1038/s41928-018-0071-7 ↗
10. 10.1038/nature1649210.1038/nature16492 ↗
11. 10.1302/0301-620X.96B10.3406810.1302/0301-620X.96B10.34068 ↗
12. 10.1007/s40735-017-0078-z10.1007/s40735-017-0078-z ↗
13. Allen, M. G. Micromachined Endovascularly-Implantable Wireless Aneurysm Pressure Sensors: From Concept to Clinic. InThe 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS ’05; 2005; Vol. 1, pp 275–278 .10.1109/SENSOR.2005.1496410 ↗
14. 10.1002/adma.20170762410.1002/adma.201707624 ↗
15. 10.1109/JMEMS.2013.229011110.1109/JMEMS.2013.2290111 ↗
16. Hänninen, A.; Salpavaara, T.; Lekkala, J.; Kellomäki, M. An Inductively Coupled Biodegradable Capacitive Pressure Sensor.Proceedings. 2018.10.3390/proceedings2130914 ↗
17. Luo, M.; Shen, W.; Allen, M. G. Microfabricated PLGA/PVA-Based Completely Biodegradable Passive RF Pressure Sensors. In2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS); 2015; pp 101–104.10.1109/TRANSDUCERS.2015.7180871 ↗
18. 10.1002/admt.20190042810.1002/admt.201900428 ↗
19. 10.1016/j.joms.2004.11.01110.1016/j.joms.2004.11.011 ↗
20. 10.1016/j.bioactmat.2018.01.00310.1016/j.bioactmat.2018.01.003 ↗
21. 10.1109/JMEMS.2010.204982510.1109/JMEMS.2010.2049825 ↗
22. 10.1016/j.msec.2016.01.03910.1016/j.msec.2016.01.039 ↗
23. 10.1016/S0142-9612(00)00105-810.1016/S0142-9612(00)00105-8 ↗
24. 10.3171/2011.4.PEDS116010.3171/2011.4.PEDS1160 ↗
25. 10.1016/j.injury.2017.04.02410.1016/j.injury.2017.04.024 ↗
26. 10.1002/term.275610.1002/term.2756 ↗
27. 10.1016/j.actbio.2012.08.02310.1016/j.actbio.2012.08.023 ↗
28. 10.1109/ICSENS.2016.780840810.1109/ICSENS.2016.7808408 ↗
29. 10.1109/JEDS.2016.260634010.1109/JEDS.2016.2606340 ↗
30. 10.1109/TBME.1967.450247410.1109/TBME.1967.4502474 ↗
31. 10.1038/ncomms602810.1038/ncomms6028 ↗
32. 10.3390/proceedings213084210.3390/proceedings2130842 ↗
33. 10.1016/S0924-4247(01)00624-010.1016/S0924-4247(01)00624-0 ↗
34. 10.1016/j.snb.2015.04.12110.1016/j.snb.2015.04.121 ↗
35. 10.1109/TAP.2009.201607310.1109/TAP.2009.2016073 ↗
36. 10.1016/j.snb.2017.05.11610.1016/j.snb.2017.05.116 ↗
37. 10.1016/j.joms.2007.11.01910.1016/j.joms.2007.11.019 ↗
38. 10.1002/adfm.20190305110.1002/adfm.201903051 ↗
39. 10.1002/adfm.20130184710.1002/adfm.201301847 ↗
40. 10.1109/3476.67002510.1109/3476.670025 ↗
41. 10.1016/j.sna.2012.08.03910.1016/j.sna.2012.08.039 ↗
42. 10.1109/TMTT.2007.89771610.1109/TMTT.2007.897716 ↗
43. 10.1002/adma.20130092010.1002/adma.201300920 ↗
44. 10.1002/adfm.20150219210.1002/adfm.201502192 ↗
45. 10.1021/acsbiomaterials.8b0129210.1021/acsbiomaterials.8b01292 ↗
46. Martin P. M. · 2009
47. 10.1016/j.tsf.2019.13750110.1016/j.tsf.2019.137501 ↗
48. 10.1116/1.160045010.1116/1.1600450 ↗
49. 10.1002/adma.20130605010.1002/adma.201306050 ↗
50. 10.1038/am.2015.11410.1038/am.2015.114 ↗
51. 10.1038/s41591-018-0196-210.1038/s41591-018-0196-2 ↗
52. 10.1088/0960-1317/20/10/10501010.1088/0960-1317/20/10/105010 ↗
53. 10.1002/adfm.20190545110.1002/adfm.201905451 ↗
54. 10.1109/JMEMS.2014.236020110.1109/JMEMS.2014.2360201 ↗
55. 10.1016/j.mattod.2017.12.00510.1016/j.mattod.2017.12.005 ↗
56. 10.1134/S106377451701002310.1134/S1063774517010023 ↗
57. 10.1016/j.actbio.2011.05.00810.1016/j.actbio.2011.05.008 ↗
58. 10.1073/pnas.140774311110.1073/pnas.1407743111 ↗
59. 10.1097/BCO.000000000000037810.1097/BCO.0000000000000378 ↗
60. 10.1002/adfm.20140346910.1002/adfm.201403469 ↗
61. 10.1002/adfm.20130429310.1002/adfm.201304293 ↗
62. 10.1038/s41551-018-0300-410.1038/s41551-018-0300-4 ↗
63. 10.1002/adfm.20130012710.1002/adfm.201300127 ↗
64. 10.1016/0042-207X(92)90149-Q10.1016/0042-207X(92)90149-Q ↗
65. 10.1016/S0924-4247(02)00319-910.1016/S0924-4247(02)00319-9 ↗
66. 10.1016/j.surfcoat.2011.02.00910.1016/j.surfcoat.2011.02.009 ↗
67. 10.1016/j.tsf.2010.12.17110.1016/j.tsf.2010.12.171 ↗
68. 10.1002/pen.2314810.1002/pen.23148 ↗
69. 10.1021/am200957910.1021/am2009579 ↗
70. 10.1021/acsami.8b1501510.1021/acsami.8b15015 ↗
71. 10.1002/adfm.20180181910.1002/adfm.201801819 ↗
72. 10.1002/adfm.20191071810.1002/adfm.201910718 ↗
73. 10.1002/anie.20160930710.1002/anie.201609307 ↗
74. 10.1016/S0142-9612(00)00101-010.1016/S0142-9612(00)00101-0 ↗
75. Salpavaara, T.; Ellä, V.; Kellomäki, M.; Lekkala, J.Biodegradable Passive Resonance Sensor: Fabrication and Initial Testing. In BIODEVICES 2015 - 8th International Conference on Biomedical Electronics and Devices; SCITEPRESS: 2015; pp 127–131.10.5220/0005255901270131 ↗
76. 10.1111/j.1551-2916.2011.05012.x10.1111/j.1551-2916.2011.05012.x ↗
77. Salpavaara T. · 2018