A novel graphene-based variable capacitor (varactor) that senses glucose based on the quantum capacitance effect was successfully developed. The sensor utilizes a metal-oxide-graphene varactor device structure that is inherently compatible with passive wireless sensing, a key advantage for in vivo glucose sensing. The graphene varactors were functionalized with pyrene-1-boronic acid (PBA) by self-assembly driven by π-π interactions. Successful surface functionalization was confirmed by both Raman spectroscopy and capacitance-voltage characterization of the devices. Through glucose binding to the PBA, the glucose concentration in the buffer solutions modulates the level of electrostatic doping of the graphene surface to different degrees, which leads to capacitance changes and Dirac voltage shifts. These responses to the glucose concentration were shown to be reproducible and reversible over multiple measurement cycles, suggesting promise for eventual use in wireless glucose monitoring.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Conducting polymers and applications · Graphene research and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States

Department of Electrical & Computer Engineering, University of Minnesota, 200 Union Street SE, Minneapolis, Minnesota 55455, United States

Division of Endocrinology, Mayo Clinic, 200 First Street SW, Rochester, Minnesota 55905, United States

Funding

Division of Electrical, Communications and Cyber Systems · Division of Materials Research · Minnesota Partnership for Biotechnology and Medical Genomics, University of Minnesota · Alice M. O'Brien Foundation

References (33)

Show source-provided references
1. 10.1126/science.110289610.1126/science.1102896 ↗
2. 10.1126/science.115799610.1126/science.1157996 ↗
3. 10.1063/1.277688710.1063/1.2776887 ↗
4. 10.1039/C1CS15270J10.1039/C1CS15270J ↗
5. 10.1021/nl901596m10.1021/nl901596m ↗
6. 10.1021/nn406342410.1021/nn4063424 ↗
7. 10.1021/acs.nanolett.5b0472910.1021/acs.nanolett.5b04729 ↗
8. 10.1038/nmat196710.1038/nmat1967 ↗
9. 10.1021/nl300129310.1021/nl3001293 ↗
10. 10.1021/nl072364w10.1021/nl072364w ↗
11. 10.1021/nl301714x10.1021/nl301714x ↗
12. 10.1016/j.bios.2016.06.07210.1016/j.bios.2016.06.072 ↗
13. 10.1039/c0nr00142b10.1039/c0nr00142b ↗
14. 10.1021/ja100503b10.1021/ja100503b ↗
15. 10.1063/1.480443810.1063/1.4804438 ↗
16. 10.1063/1.365133410.1063/1.3651334 ↗
17. 10.1063/1.369839410.1063/1.3698394 ↗
18. 10.1021/am501705710.1021/am5017057 ↗
19. 10.1109/JSEN.2013.229530210.1109/JSEN.2013.2295302 ↗
20. 10.1021/nl201781q10.1021/nl201781q ↗
21. 10.1021/nl203666a10.1021/nl203666a ↗
22. 10.1021/acs.jpcc.5b0593010.1021/acs.jpcc.5b05930 ↗
23. Zhang, Y.; Ma, R.; Kudva, Y. C.; Bühlmann, P.; Koester, S. J.Glucose Sensing with Graphene Varactors. InIEEE Sensors;SENSORS 2016—Proceedings:Orlando, FL, October 30–November 2, 2016.10.1109/ICSENS.2016.7808854 ↗
24. 10.1002/anie.19961910110.1002/anie.199619101 ↗
25. 10.1039/C5NR08866F10.1039/C5NR08866F ↗
26. 10.1021/ja00168a02210.1021/ja00168a022 ↗
27. 10.1039/b003010o10.1039/b003010o ↗
28. 10.1021/ja010521210.1021/ja0105212 ↗
29. 10.1016/S0040-4020(02)00489-110.1016/S0040-4020(02)00489-1 ↗
30. 10.1021/acs.langmuir.6b0337910.1021/acs.langmuir.6b03379 ↗
31. 10.1016/j.jelechem.2013.01.00710.1016/j.jelechem.2013.01.007 ↗
32. 10.1016/j.memsci.2015.02.04510.1016/j.memsci.2015.02.045 ↗
33. 10.1002/adma.20080075710.1002/adma.200800757 ↗