Transforming the Fabrication and Biofunctionalization of Gold Nanoelectrode Arrays into Versatile Electrochemical Glucose Biosensors
Source abstract
Abstract
High-density arrays of conducting nanoelectrodes (i.e., nanoelectrode arrays [NEAs]) have been developed on the surface of a single electrode for numerous electrochemical sensing paradigms. However, a scalable fabrication technique and robust biofunctionalization protocol are oftentimes lacking and thus many NEA designs have limited efficacy and overall commercial viability in biosensing applications. In this report, we develop a lithography-free nanofabrication protocol to create large arrays of Au nanoelectrodes on a silicon wafer via a porous anodic alumina template. To demonstrate their effectiveness as electrochemical glucose biosensors, alkanethiol self-assembled monolayers (SAMs) are used to covalently attach the enzyme glucose oxidase to the Au NEA surface for subsequent glucose sensing. The sensitivity and linear sensing range of the biosensor is controlled by introducing higher concentrations of long-chain SAMs (11-mercaptoundecanoic acid: MUA) with short-chain SAMs (3-mercaptopropionic acid: MPA) into the enzyme immobilization scheme. This facile NEA fabrication protocol (that is well-suited for integration into electronic devices) and biosensor performance controllability (via the mixed-length enzyme-conjugated SAMs) transforms the Au NEAs into versatile glucose biosensors. Thus these Au NEAs could potentially be used in important real-word applications such as in health-care and bioenergy where biosensors with very distinct sensing capabilities are needed.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advanced biosensing and bioanalysis techniques · Electrochemical sensors and biosensors · Electrochemical Analysis and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Birck Nanotechnology Center, West Lafayette, Indiana 47907, United States
Bindley Bioscience Center−Physiological Sensing Facility, West Lafayette, Indiana 47907, United States
Department of Agricultural and Biological Engineering, West Lafayette, Indiana 47907, United States
School of Mechanical Engineering, West Lafayette, Indiana 47907, United States
Weldon School of Biomedical Engineering, West Lafayette, Indiana 47907, United States
References (47)
Show source-provided references
1. Alivisatos P. · Nat. Biotechnol. · 2004 · 22 · 4710.1038/nbt927 ↗
2. Drummond T. G. · Nat. Biotechnol. · 2003 · 21 · 119210.1038/nbt873 ↗
3. Murray R. W. · Chem. Rev. · 2008 · 108 · 268810.1021/cr068077e ↗
4. Arrigan D. W. M. · Analyst · 2004 · 129 · 115710.1039/b415395m ↗
5. Compton R. G. · Chem. Phys. Lett. · 2008 · 459 · 110.1016/j.cplett.2008.03.095 ↗
6. Jena B. K. · Anal. Chem. · 2010 · 1041
7. Li Y. · J. Am. Chem. Soc. · 2010 · 132 · 304710.1021/ja909408q ↗
8. Ito T. · Anal. Chem. · 2006 · 78 · 704810.1021/ac061043m ↗
9. Lanyon Y. H. · Sens. Actuators, B · 2007 · 121 · 34110.1016/j.snb.2006.11.029 ↗
10. Le Saux G. · ACS Appl. Mater. Interfaces · 2009 · 1 · 247710.1021/am900427w ↗
11. Lupu A. · Sens. Actuators, B · 2009 · 137 · 5610.1016/j.snb.2008.10.004 ↗
12. Sandison M. E. · Lab Chip · 2006 · 6 · 102010.1039/b516598a ↗
13. Sander M. S. · Adv. Funct. Mater. · 2003 · 13 · 39310.1002/adfm.200304290 ↗
14. Luong J. H. T. · Biotechnol. Adv · 2008 · 26 · 49210.1016/j.biotechadv.2008.05.007 ↗
15. Newman J. D. · Biosens. Bioelectron. · 2005 · 20 · 243510.1016/j.bios.2004.11.012 ↗
16. De Leo M. · Electroanalysis · 2007 · 19 · 22710.1002/elan.200603724 ↗
17. Menon V. P. · Anal. Chem. · 1995 · 67 · 192010.1021/ac00109a003 ↗
18. Perera D. M. N. T. · Analyst · 2009 · 135 · 17210.1039/B917517B ↗
19. Borissov D. · J. Phys. Chem. C · 2009 · 113 · 313310.1021/jp809202h ↗
20. Shin C. · Electrochim. Acta · 2007 · 53 · 72010.1016/j.electacta.2007.07.040 ↗
21. Tan L. K. · J. Phys. Chem. C · 2007 · 111 · 496410.1021/jp066841v ↗
22. Mucelli S. P. · Biosens. Bioelectron. · 2008 · 23 · 190010.1016/j.bios.2008.02.027 ↗
23. Rucker V. C. · Langmuir · 2005 · 21 · 762110.1021/la050251r ↗
24. Piao Y. · J. Nanosci. Nanotechnol. · 2009 · 9 · 221510.1166/jnn.2009.SE42 ↗
25. Karyakin A. A. · Anal. Chem. · 1995 · 67 · 241910.1021/ac00110a016 ↗
26. Kang X. · Anal. Biochem. · 2007 · 369 · 7110.1016/j.ab.2007.07.005 ↗
27. Chen H. · Biosens. Bioelectron. · 2007 · 22 · 181110.1016/j.bios.2006.08.013 ↗
28. Masson J. F. · Biosens. Bioelectron. · 2007 · 23 · 35510.1016/j.bios.2007.04.013 ↗
29. Chaki N. K. · Biosens. Bioelectron. · 2002 · 17 · 110.1016/S0956-5663(01)00277-9 ↗
30. Evans S. D. · Chem. Phys. Lett. · 1990 · 170 · 46210.1016/S0009-2614(90)87085-6 ↗
31. Love J. C. · Chem. Rev. · 2005 · 105 · 110310.1021/cr0300789 ↗
32. Anandan V. · Sensors · 2009 · 9 · 129510.3390/s90301295 ↗
33. Campuzano S. · J. Electroanal. Chem. · 2002 · 526 · 9210.1016/S0022-0728(02)00753-2 ↗
34. Campuzano S. · J. Electroanal. Chem. · 2006 · 586 · 11210.1016/j.jelechem.2005.09.007 ↗
35. Gooding J. J. · TrAC Trends Anal. Chem. · 1999 · 18 · 52510.1016/S0165-9936(99)00133-8 ↗
36. Claussen J. C. · ACS Nano · 2009 · 3 · 3710.1021/nn800682m ↗
37. Claussen J. C. · J. Diabetes Sci. Technol. · 2010 · 4 · 31210.1177/193229681000400211 ↗
38. Franklin A. D. · Appl. Phys. Lett. · 2008 · 92 · 01312210.1063/1.2831002 ↗
39. Ding S. J. · Anal. Chim. Acta · 2005 · 554 · 4310.1016/j.aca.2005.08.046 ↗
40. Bain C. D. · J. Am. Chem. Soc. · 1989 · 111 · 715510.1021/ja00200a039 ↗
41. Liu Y. Y. · Nanoscale Res. Lett. · 2009 · 4 · 21010.1007/s11671-008-9227-0 ↗
42. Cherevko S. · Sens. Actuators, B · 2009 · 142 · 21610.1016/j.snb.2009.07.023 ↗
43. Mena M. L. · Anal. Biochem. · 2005 · 336 · 2010.1016/j.ab.2004.07.038 ↗
44. Delvaux M. · Biosens. Bioelectron. · 2005 · 20 · 158710.1016/j.bios.2004.07.017 ↗
45. Li Y. · Electrochem. Commun. · 2007 · 9 · 98110.1016/j.elecom.2006.11.035 ↗
46. Li X. · Biotechnol. Bioeng. · 2007 · 98 · 76410.1002/bit.21489 ↗
47. Öhgren K. · J. Biotechnol. · 2006 · 126 · 48810.1016/j.jbiotec.2006.05.001 ↗