journal article·2015-04-29

Microscale Sensing of Oxygen via Encapsulated Porphyrin Nanofibers: Effect of Indicator and Polymer “Core” Permeability

Ruipeng Xue, Chen Ge, Kris Richardson, Andre Palmer, Mariano Viapiano, John J. Lannutti

Publisher page

Abstract

Biomimetic polymer nanofibers integrate sensing capabilities creating utility across many biological and biomedical applications. We created fibers consisting of either a poly(ether sulfone) (PES) or a polysulfone (PSU) core coated by a biocompatible polycaprolactone (PCL) shell to facilitate cell attachment. Oxygen sensitive luminescent probes Pt(II) meso-tetra(pentafluorophenyl)porphine (PtTFPP) or Pd(II) meso-tetra(pentafluorophenyl)porphine (PdTFPP), were incorporated in the core via single-step coaxial electrospinning providing superior sensitivity, high brightness, linear response, and excellent stability. Both PES-PCL and PSU-PCL fibers provide more uniform probe distribution than polydimethylsiloxane (PDMS). PSU-based sensing fibers possessed optimum sensitivity due to their relatively higher oxygen permeability. During exposure to 100% nitrogen and 100% oxygen, PES-PCL fiber displayed an I0/I100 value of 6.7; PSU-PCL exhibited a value of 8.9 with PtTFPP as the indicator. In contrast, PdTFPP-containing fibers possess higher sensitivity due to the long porphyrin lifetime. The corresponding I0/I100 values were 80.6 and 106.7 for the PES-PCL and PSU-PCL matrices, respectively. The response and recovery times were 0.24/0.39 s for PES-PCL and 0.38/0.83 s for PSU-PCL which are 0.12 and 0.11 s faster, respectively, than the Pt-based porphyrin in the same matrices. Paradoxically, lower oxygen permeabilities make these polymers better suited to measuring higher (i. e., ∼20%) oxygen contents than PDMS. Individual fiber sensing was studied by fluorescence spectrometry and at a sub-micrometer scale by total internal reflection fluorescence (TIRF). Specific polymer blends relate polymer composition to the resulting sensor properties. All compositions displayed linear Stern-Volmer plots; sensitivity could be tailored by matrix or the sensing probe selection.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Analytical Chemistry and Sensors · Electrochemical sensors and biosensors · Conducting polymers and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Neurosurgery, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts 02115, United States

Funding

Division of Engineering Education and Centers · Institute for Materials Research, Ohio State University · Division of Civil, Mechanical and Manufacturing Innovation

References (38)

Show source-provided references
1. Semenza G. L. · Science · 2007 · 318 · 6210.1126/science.1147949 ↗
2. Napp J. · Anal. Chem. · 2011 · 83 · 903910.1021/ac201870b ↗
3. Ji J. · J. Biomed. Opt. · 2002 · 7 · 40410.1117/1.1483082 ↗
4. Lecoq J. · Nat. Med. · 2011 · 17 · 89310.1038/nm.2394 ↗
5. Suresh S. · J. Chem. Technol. Biotechnol. · 2009 · 84 · 109110.1002/jctb.2154 ↗
6. Wang X.-d. · Chem. Soc. Rev. · 2014 · 43 · 366610.1039/C4CS00039K ↗
7. Wang X.-d. · J. Am. Chem. Soc. · 2012 · 134 · 1701110.1021/ja308830e ↗
8. Habibagahi A. · ACS Appl. Mater. Interfaces · 2009 · 1 · 178510.1021/am900306a ↗
9. Fercher A. · ACS Nano · 2011 · 5 · 549910.1021/nn200807g ↗
10. Thomas P. C. · Anal. Chem. · 2009 · 81 · 923910.1021/ac9013379 ↗
11. Baleizao C. · Anal. Chem. · 2008 · 80 · 644910.1021/ac801034p ↗
12. Tian Y. Q. · Sens. Actuators, B · 2010 · 150 · 57910.1016/j.snb.2010.08.036 ↗
13. Xue R. · Sens. Actuators, B · 2014 · 192 · 69710.1016/j.snb.2013.10.084 ↗
14. Wang L.-Y. · J. Lumin. · 2011 · 131 · 127710.1016/j.jlumin.2011.03.017 ↗
15. Quaranta M. · Bioanal. Rev. · 2012 · 4 · 11510.1007/s12566-012-0032-y ↗
16. Tian Y. Q. · Chem. Mater. · 2010 · 22 · 206910.1021/cm903361y ↗
17. Spellane P. J. · Inorg. Chem. · 1980 · 19 · 38610.1021/ic50204a021 ↗
18. Lai S.-W. · Inorg. Chem. · 2004 · 43 · 372410.1021/ic049902h ↗
19. Kneas K. A. · Microsc. Microanal. · 2000 · 6 · 55110.1007/S100050010052 ↗
20. Evans R. C. · ACS Appl. Mater. Interfaces · 2009 · 1 · 102310.1021/am900007m ↗
21. McKeen L. W. · 2012
22. Arai T. · ACS Appl. Mater. Interfaces · 2012 · 4 · 545310.1021/am3013664 ↗
23. Nam J. · J. Appl. Polym. Sci. · 2008 · 107 · 154710.1002/app.27063 ↗
24. Hartmann P. · Anal. Chem. · 1995 · 67 · 8810.1021/ac00097a015 ↗
25. Reneker D. H. · 2007 · 41 · 43
26. Xue R. · Mater. Sci. Eng., C · 2013 · 33 · 345010.1016/j.msec.2013.04.030 ↗
27. Lakowicz J. R. · 200610.1007/978-0-387-46312-4 ↗
28. Demas J. N. · Anal. Chem. · 1995 · 67 · 137710.1021/ac00104a012 ↗
29. Grist S. M. · Sensors · 2010 · 10 · 928610.3390/s101009286 ↗
30. Eastwood D. · J. Mol. Spectrosc. · 1970 · 35 · 35910.1016/0022-2852(70)90179-7 ↗
31. Borisov S. M. · Anal. Chim. Acta · 2011 · 690 · 10810.1016/j.aca.2011.01.057 ↗
32. Kellner K. · Biotechnol. Bioeng. · 2002 · 80 · 7310.1002/bit.10352 ↗
33. Klimant I. · Anal. Chem. · 1995 · 67 · 316010.1021/ac00114a010 ↗
34. Sinkala E. · Lab Chip · 2010 · 10 · 329110.1039/c0lc00244e ↗
35. Wang X. · J. Mater. Chem. · 2012 · 22 · 1606610.1039/c2jm32122j ↗
36. Abdel-Shafi A. A. · J. Phys. Chem. A · 1999 · 104 · 19210.1021/jp991876z ↗
37. Moreno M. J. · Sens. Actuators, B · 2003 · 90 · 8210.1016/S0925-4005(03)00057-1 ↗
38. Rao S. S. · Biomaterials · 2013 · 34 · 518110.1016/j.biomaterials.2013.03.069 ↗