journal article·2010-12-22

All-(111) Surface Silicon Nanowires: Selective Functionalization for Biosensing Applications

M. N. Masood, S. Chen, E. T. Carlen, A. van den Berg

Publisher page

Abstract

We demonstrate the utilization of selective functionalization of carbon-silicon (C-Si) alkyl and alkenyl monolayers covalently linked to all-(111) surface silicon nanowire (Si-NW) biosensors. Terminal amine groups on the functional monolayer surfaces were used for conjugation of biotin n-hydroxysuccinimide ester. The selective functionalization is demonstrated by contact angle, X-ray photoelectron spectroscopy (XPS), and high-resolution scanning electron microscopy (HRSEM) of 5 nm diameter thiolated Au nanoparticles linked with streptavidin and conjugated to the biotinylated all-(111) surface Si-NWs. Electrical measurements of monolayer passivated Si-NWs show improved device behavior and performance. Furthermore, an analytical model is presented to demonstrate the improvement in detection sensitivity of the alkyl and alkenyl passivated all-(111) Si-NW biosensors compared to conventional nanowire biosensor geometries and silicon dioxide passivation layers as well as interface design and electrical biasing guidelines for depletion-mode sensors.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Nanowire Synthesis and Applications · Semiconductor materials and interfaces · Semiconductor materials and devices

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

BIOS Lab on a Chip Group, MESA+ Institute for Nanotechnology, University of Twente, Enschede 7500 AE, The Netherlands

References (34)

Show source-provided references
1. Cui Y. · Science · 2001 · 293 · 128910.1126/science.1062711 ↗
2. Bunimovich Y. L. · J. Am. Chem. Soc. · 2006 · 128 · 1632310.1021/ja065923u ↗
3. Gao Z. Q. · Anal. Chem. · 2007 · 79 · 329110.1021/ac061808q ↗
4. Patolsky F. · Mater. Today · 2005
5. Wanekaya A. K. · Electroanalysis · 2006 · 18 · 53310.1002/elan.200503449 ↗
6. Tong H. D. · Nano Lett. · 2009 · 9 · 101510.1021/nl803181x ↗
7. Chen S. · ACS Nano · 2009 · 3 · 348510.1021/nn901220g ↗
8. Buriak J. M. · Chem. Rev. · 2002 · 102 · 127210.1021/cr000064s ↗
9. A ligand refers to a receptor biomolecule attached to the sensor surface. An analyte refers to the complementary biomolecule in the solution. A ligand-analyte pair is a selectively hybridized biomolecular conjugate.
10. van der Voort D. · Sens. Actuator, B · 2005 · 105 · 5010.1016/j.snb.2004.02.035 ↗
11. Bunimovich Y. L. · Langmuir · 2004 · 20 · 1063010.1021/la047913h ↗
12. Park I. · Nano Lett. · 2007 · 7 · 310610.1021/nl071637k ↗
13. Zhang G.-J. · Nano Lett. · 2008 · 8 · 106610.1021/nl072991l ↗
14. Doping concentration dependent carrier mobility has been included in all calculations.
15. Sze S. M. · 1981
16. The calculated sensitivity data is normalized to the maximum sensitivity occurring fortf= 1 nm andNa= 1017 cm−3at Ψo= 0. For the surface charge sensitivity calculation, εw= 80 andco= 10 mM.
17. Israelachvili J. · 1992
18. Fritz J. · Proc. Natl. Acad. Sci. U.S.A. · 2002 · 99 · 1414210.1073/pnas.232276699 ↗
19. Kar S. · Appl. Phys. Lett. · 2001 · 78 · 128810.1063/1.1351530 ↗
20. Weldon M. K. · Surf. Sci. · 2002 · 500 · 85910.1016/S0039-6028(01)01585-0 ↗
21. Leão C. R. · Nano Lett. · 2007 · 7 · 117210.1021/nl0628697 ↗
22. Scheres L. · Langmuir · 2010 · 26 · 479010.1021/la9035503 ↗
23. Wu Y. · Nano Lett. · 2004 · 4 · 43310.1021/nl035162i ↗
24. Choi Y.-K. · J. Vac. Sci. Technol., B · 2003 · 21 · 295110.1116/1.1627805 ↗
25. Stern E. · Nature · 2007 · 445 · 51910.1038/nature05498 ↗
26. Yablonovitch E. · Phys. Rev. Lett. · 1986 · 57 · 24910.1103/PhysRevLett.57.249 ↗
27. Cheng Y. C. · Prog. Surf. Sci. · 1977 · 8 · 18110.1016/0079-6816(77)90003-X ↗
28. Bent S. F. · Surf. Sci. · 2002 · 500 · 87910.1016/S0039-6028(01)01553-9 ↗
29. Puniredd S. R. · J. Am. Chem. Soc. · 2008 · 130 · 1372710.1021/ja804674z ↗
30. Zuilhof H. · Adv. Mater. · 2000 · 12 · 145710.1002/1521-4095(200010)12:19<1457::AID-ADMA1457>3.0.CO;2-# ↗
31. Ciero R. L. · Langmuir · 2002 · 18 · 30510.1021/la010823h ↗
32. Gorostiza P. · J. Phys. Chem. B · 2006 · 110 · 557610.1021/jp054825c ↗
33. The maximum ideal current in the undepleted triangular isids≈qμbNavdsL−1wh/2 with μb≈ 300 cm2V−1s−1,Na= 1 × 1017cm−3,vds= 100 mV,L= 10 μm,h= 100 nm, andw= 2h/tan(54.74°), where μbis the concentration-dependent hole mobility.
34. The alkenyl monolayer Si-NW sensitivity was estimated for Δψ = 10 mV:Go= 2 nA/vdsandG= 63 pA/mV × 10 mV/vds= 0.63 nA/vdsand ΔG/Go= 0.315. The oxide Si-NW sensitivity was estimated for Δψ = 10 mV:Go= 10 nA/vdsandG= 36 pA/mV × 10 mV/vds=0.36 nA/vdsand ΔG/Go= 0.036.