journal article·2016-01-13

Implantable Graphene-based Neural Electrode Interfaces for Electrophysiology and Neurochemistry in In Vivo Hyperacute Stroke Model

Ta-Chung Liu, Min-Chieh Chuang, Chao-Yi Chu, Wei-Chen Huang, Hsin-Yi Lai, Chao-Ting Wang, Wei-Lin Chu, San-Yuan Chen, You-Yin Chen

Publisher page

Abstract

Implantable microelectrode arrays have attracted considerable interest due to their high temporal and spatial resolution recording of neuronal activity in tissues. We herein presented an implantable multichannel neural probe with multiple real-time monitoring of neural-chemical and neural-electrical signals by a nonenzymatic neural-chemical interface, which was designed by creating the newly developed reduced graphene oxide-gold oxide (rGO/Au2O3) nanocomposite electrode. The modified electrode on the neural probe was prepared by a facile one-step cyclic voltammetry (CV) electrochemical method with simultaneous occurrence of gold oxidation and GOs reduction to induce the intimate attachment by electrostatic interaction using chloride ions (Cl(-)). The rGO/Au2O3-modified electrode at a low deposition scan rate of 10 mVs(-1) displayed significantly improved electrocatalytic activity due to large active areas and well-dispersive attached rGO sheets. The in vitro amperometric response to H2O2 demonstrated a fast response of less than 5 s and a very low detection limit of 0.63 μM. In in vivo hyperacute stroke model, the concentration of H2O2 was measured as 100.48 ± 4.52 μM for rGO/Au2O3 electrode within 1 h photothrombotic stroke, which was much higher than that (71.92 μM ± 2.52 μM) for noncoated electrode via in vitro calibration. Simultaneously, the somatosensory-evoked potentials (SSEPs) test provided reliable and precise validation for detecting functional changes of neuronal activities. This newly developed implantable probe with localized rGO/Au2O3 nanocomposite electrode can serve as a rapid and reliable sensing platform for practical H2O2 detection in the brain or for other neural-chemical molecules in vivo.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Conducting polymers and applications · Neuroscience and Neural Engineering

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Materials Science and Engineering, National Chiao Tung University, No. 1001, Ta-Hsueh Rd., Hsinchu, Taiwan 300, Republic of China

Department of Chemistry, Tunghai University, No. 181, Sec. 3, Taichung Port Rd., Taichung, Taiwan 407, Republic of China

Department of Materials Science and Engineering, Carnegie Mellon University, No.5000 Forbes Avenue, Wean Hall 3325, Pittsburgh, Pennsylvania 15213, United States

Interdisciplinary Institute of Neuroscience and Technology, Zhejiang University, No.866 Yuhangtang Rd., Hangzhou, Zhejiang Province 310058, China

Department of Biomedical Engineering, National Yang Ming University, No.155, Sec. 2, Linong St., Taipei, Taiwan 112, Republic of China

Department of Biomedical Engineering, University of Michigan, No.2200 Bonisteel Boulevard, Ann Arbor, Michigan 48109-2099, United States

Funding

Ministry of Science and Technology, Taiwan

References (35)

Show source-provided references
1. 10.1002/adma.20130449610.1002/adma.201304496 ↗
2. 10.1016/j.jneumeth.2008.06.03610.1016/j.jneumeth.2008.06.036 ↗
3. 10.1088/0957-4484/21/8/08530310.1088/0957-4484/21/8/085303 ↗
4. 10.1146/annurev.bioeng.10.061807.16051810.1146/annurev.bioeng.10.061807.160518 ↗
5. 10.1016/j.biomaterials.2007.11.02210.1016/j.biomaterials.2007.11.022 ↗
6. 10.1007/s10544-013-9804-610.1007/s10544-013-9804-6 ↗
7. 10.1039/C3TB21171A10.1039/C3TB21171A ↗
8. 10.1016/j.snb.2010.11.05610.1016/j.snb.2010.11.056 ↗
9. 10.1016/j.bios.2010.04.04010.1016/j.bios.2010.04.040 ↗
10. 10.1016/S0003-2670(00)01204-610.1016/S0003-2670(00)01204-6 ↗
11. 10.1021/cr068010r10.1021/cr068010r ↗
12. 10.1039/b923596e10.1039/b923596e ↗
13. 10.1126/science.115818010.1126/science.1158180 ↗
14. 10.1021/cr300115g10.1021/cr300115g ↗
15. 10.1016/j.trac.2010.05.01110.1016/j.trac.2010.05.011 ↗
16. 10.1039/c2jm34870e10.1039/c2jm34870e ↗
17. 10.1016/0891-5849(89)90056-710.1016/0891-5849(89)90056-7 ↗
18. 10.3171/jns.1986.64.5.080310.3171/jns.1986.64.5.0803 ↗
19. 10.3390/s15020270910.3390/s150202709 ↗
20. 10.1007/s13404-013-0094-910.1007/s13404-013-0094-9 ↗
21. 10.1039/c3nr33954h10.1039/c3nr33954h ↗
22. 10.1021/am503110s10.1021/am503110s ↗
23. 10.1016/j.nbd.2014.12.02210.1016/j.nbd.2014.12.022 ↗
24. 10.1016/j.jneumeth.2009.05.01010.1016/j.jneumeth.2009.05.010 ↗
25. 10.1016/j.elecom.2010.11.03310.1016/j.elecom.2010.11.033 ↗
26. 10.1149/1.212408510.1149/1.2124085 ↗
27. 10.1016/j.elecom.2006.08.05010.1016/j.elecom.2006.08.050 ↗
28. 10.1103/PhysRevB.64.07541410.1103/PhysRevB.64.075414 ↗
29. 10.1126/science.111942610.1126/science.1119426 ↗
30. 10.1080/0003271000854319610.1080/00032710008543196 ↗
31. 10.1002/elan.20100009410.1002/elan.201000094 ↗
32. 10.1016/j.electacta.2011.02.10510.1016/j.electacta.2011.02.105 ↗
33. Paxinos G. · 2006
34. 10.1016/0006-8993(94)01291-O10.1016/0006-8993(94)01291-O ↗
35. 10.1161/01.STR.21.1.12410.1161/01.STR.21.1.124 ↗