Graphene Functionalization by O2, H2, and Ar Plasma Treatments for Improved NH3 Gas Sensing
Source abstract
Abstract
High Resolution Image Download MS PowerPoint Slide Graphene-based materials have gained attention for their promise in various applications owing to their two-dimensional structure. Functionalizing the graphene surface can help realize materials with noble properties. In this study, graphene was functionalized by plasma treatment in O 2, H 2, and Ar environments, and the effects on the NH 3 gas-sensing performance were evaluated. The O 2 plasma treatment induced oxidation of the graphene (i.e., graphoxide), while the H 2 plasma treatment induced hydrogenation (i.e., graphane). Raman scattering spectroscopy suggested that graphoxide had vacancy-type defects and graphane had sp 3 -type defects, while Ar-treated graphene had both types of defects. Graphane had the highest sheet resistance followed by graphoxide, Ar-treated graphene, and pristine graphene, which can be attributed to the large bandgap of 3.0 eV for graphane. In contrast, graphoxide had the best NH 3 gas-sensing performance, which indicates that NH 3 gas interacts more strongly with vacancy-type defects than with sp 3 -type defects. The results showed that functionalizing the graphene structure generated noble materials with a superior NH 3 gas-sensing performance compared with pristine graphene.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Gas Sensing Nanomaterials and Sensors · Graphene research and applications · Advanced Sensor and Energy Harvesting Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Graduate School of Science, Chiba University, 1-33 Yayoi, Inage, Chiba 263-8522, Japan
Funding
Japan Society for the Promotion of Science
References (59)
Show source-provided references
1. Capone S. · J. Optoelectron. Adv. Mater. · 2003 · 5 · 1335
2. 10.1134/S106193482202008310.1134/S1061934822020083 ↗
3. 10.1007/s12034-021-02581-510.1007/s12034-021-02581-5 ↗
4. 10.1039/D0RA09438B10.1039/D0RA09438B ↗
5. 10.3390/chemosensors1009035510.3390/chemosensors10090355 ↗
6. 10.1103/PhysRevLett.100.01660210.1103/PhysRevLett.100.016602 ↗
7. 10.1016/j.ssc.2008.02.02410.1016/j.ssc.2008.02.024 ↗
8. 10.1002/adfm.20180679210.1002/adfm.201806792 ↗
9. 10.1016/S1369-7021(12)70114-110.1016/S1369-7021(12)70114-1 ↗
10. 10.1126/science.115799610.1126/science.1157996 ↗
11. 10.1002/adem.20210128310.1002/adem.202101283 ↗
12. 10.1103/PhysRevB.77.12541610.1103/PhysRevB.77.125416 ↗
13. 10.1038/nmat196710.1038/nmat1967 ↗
14. 10.1016/j.matlet.2015.11.12910.1016/j.matlet.2015.11.129 ↗
15. 10.1186/s11671-016-1343-710.1186/s11671-016-1343-7 ↗
16. 10.1016/j.snb.2016.12.07510.1016/j.snb.2016.12.075 ↗
17. 10.1039/C9NA00048H10.1039/C9NA00048H ↗
18. 10.1021/jp312285310.1021/jp3122853 ↗
19. 10.1007/s11783-013-0491-610.1007/s11783-013-0491-6 ↗
20. 10.1021/acsomega.7b0208510.1021/acsomega.7b02085 ↗
21. 10.1186/s11671-019-3060-510.1186/s11671-019-3060-5 ↗
22. 10.1021/nl801300710.1021/nl8013007 ↗
23. 10.1021/jp802102410.1021/jp8021024 ↗
24. 10.1039/C9CP05586J10.1039/C9CP05586J ↗
25. 10.1126/science.117124510.1126/science.1171245 ↗
26. 10.1021/acs.langmuir.1c0237210.1021/acs.langmuir.1c02372 ↗
27. 10.1103/PhysRevB.54.1116910.1103/PhysRevB.54.11169 ↗
28. 10.1103/PhysRevLett.77.386510.1103/PhysRevLett.77.3865 ↗
29. 10.1103/PhysRevB.13.518810.1103/PhysRevB.13.5188 ↗
30. 10.1021/nl902623y10.1021/nl902623y ↗
31. 10.1126/science.115696510.1126/science.1156965 ↗
32. 10.1098/rsta.2004.145410.1098/rsta.2004.1454 ↗
33. 10.1039/B613962K10.1039/B613962K ↗
34. 10.1103/PhysRevLett.88.02740110.1103/PhysRevLett.88.027401 ↗
35. 10.3390/ma1101009310.3390/ma11010093 ↗
36. 10.1103/PhysRevLett.97.18740110.1103/PhysRevLett.97.187401 ↗
37. 10.1063/1.497902310.1063/1.4979023 ↗
38. 10.1038/nnano.2008.6710.1038/nnano.2008.67 ↗
39. 10.1021/nl300901a10.1021/nl300901a ↗
40. 10.1038/ncomms418610.1038/ncomms4186 ↗
41. 10.1007/s40843-023-2833-y10.1007/s40843-023-2833-y ↗
42. 10.1016/j.carbon.2009.12.05710.1016/j.carbon.2009.12.057 ↗
43. 10.1103/PhysRevX.8.02105110.1103/PhysRevX.8.021051 ↗
44. 10.1038/srep0016610.1038/srep00166 ↗
45. 10.1063/1.490503910.1063/1.4905039 ↗
46. 10.1021/acs.jpcc.3c0239410.1021/acs.jpcc.3c02394 ↗
47. 10.1039/C7NR01120B10.1039/C7NR01120B ↗
48. 10.1088/0957-4484/24/24/24550210.1088/0957-4484/24/24/245502 ↗
49. 10.3390/s1812440510.3390/s18124405 ↗
50. 10.3390/mi1111096510.3390/mi11110965 ↗
51. 10.1002/adfm.20150547710.1002/adfm.201505477 ↗
52. 10.1016/j.diamond.2016.11.01310.1016/j.diamond.2016.11.013 ↗
53. 10.1166/jnn.2018.1556310.1166/jnn.2018.15563 ↗
54. 10.1016/j.snb.2017.05.11710.1016/j.snb.2017.05.117 ↗
55. 10.1039/C4CP03552F10.1039/C4CP03552F ↗
56. 10.1186/1556-276X-9-25110.1186/1556-276X-9-251 ↗
57. 10.1039/c4nj00162a10.1039/c4nj00162a ↗
58. 10.1021/acsami.9b2176510.1021/acsami.9b21765 ↗
59. 10.1016/j.snb.2016.01.08610.1016/j.snb.2016.01.086 ↗