journal article·2022-05-18

Anisotropy of Additively Manufactured Co–28Cr–6Mo Influences Mechanical Properties and Biomedical Performance

Srijan Acharya, Vasanth Gopal, Saurabh Kumar Gupta, Sagar Nilawar, Geetha Manivasagam, Satyam Suwas, Kaushik Chatterjee

ACS Applied Materials & Interfaces· Volume 14· Issue 19
Publisher page

Abstract

Additive manufacturing (AM) of biomedical alloys such as Co-Cr-Mo alloys holds immense potential for fabricating implants with complex geometry and tailored to meet patient-specific needs. However, layer-by-layer fabrication in AM processes results in undesired anisotropy due to the solidification texture and grain morphology. The present study aimed to investigate the effect of build orientation on the mechanical properties and functional performance, including tribocorrosion behavior and cytocompatibility of an orthopedic Co-28Cr-6Mo alloy manufactured by selective laser melting. Although the fabricated alloy showed weak crystallographic texture due to the rotational scanning strategy, significant anisotropy was found in the tensile properties due to the grain size and morphology. The presence of larger, elongated grains along the build direction as compared to smaller, equiaxed grains perpendicular to the build direction imparted the observed tensile anisotropy. Quantitative analysis based on current models for strengthening mechanisms is insufficient to explain the observed anisotropy, which is ascribed to the possible role of the cellular dendrites and stacking fault strengthening in Co-Cr alloys. Unlike the electrochemical behavior, which was largely independent of the build orientation, the bio-tribocorrosion studies revealed an anisotropic wear rate under fretting conditions. Osteoblast attachment and proliferation were found to be higher on the plane perpendicular to the build direction, owing to the differences in grain size. This work provides novel insights into the role of the manufacturing parameters in a selective-laser-melted Co-Cr alloy and its potential application in engineering load-bearing orthopedic implants.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Additive Manufacturing Materials and Processes · Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Materials Engineering, Indian Institute of Science, Sir C.V. Raman Avenue, Bangalore 560012, India

Centre for Biomaterials, Cellular and Molecular Theranostics (CBCMT), Vellore Institute of Technology, Vellore 632014, Tamil Nadu, India

Funding

Department of Science and Technology, Ministry of Science and Technology

References (46)

Show source-provided references
1. 10.1016/j.pmatsci.2017.08.00310.1016/j.pmatsci.2017.08.003 ↗
2. 10.1016/j.addma.2019.04.01610.1016/j.addma.2019.04.016 ↗
3. 10.1016/j.actamat.2018.09.06410.1016/j.actamat.2018.09.064 ↗
4. 10.1016/j.msea.2019.13826810.1016/j.msea.2019.138268 ↗
5. 10.1016/j.addma.2019.04.01110.1016/j.addma.2019.04.011 ↗
6. 10.1016/j.actamat.2010.02.00410.1016/j.actamat.2010.02.004 ↗
7. 10.1016/j.addma.2014.08.00210.1016/j.addma.2014.08.002 ↗
8. 10.1007/s11661-010-0388-y10.1007/s11661-010-0388-y ↗
9. 10.1016/j.actamat.2015.07.01410.1016/j.actamat.2015.07.014 ↗
10. 10.1016/j.jmbbm.2016.02.03210.1016/j.jmbbm.2016.02.032 ↗
11. 10.1557/s43578-021-00244-z10.1557/s43578-021-00244-z ↗
12. 10.1016/J.MSEC.2019.10975510.1016/J.MSEC.2019.109755 ↗
13. 10.1080/09506608.2020.173582910.1080/09506608.2020.1735829 ↗
14. 10.1016/S0142-9612(97)00146-410.1016/S0142-9612(97)00146-4 ↗
15. 10.1016/j.mser.2014.10.00110.1016/j.mser.2014.10.001 ↗
16. Atapek Ş. H. · Mach., Technol., Mater. · 2016 · 10 · 61
17. 10.1557/jmr.2014.16310.1557/jmr.2014.163 ↗
18. 10.1007/s10856-018-6043-710.1007/s10856-018-6043-7 ↗
19. 10.1016/j.wear.2013.04.00710.1016/j.wear.2013.04.007 ↗
20. 10.1016/j.wear.2016.11.04810.1016/j.wear.2016.11.048 ↗
21. 10.1016/j.jmbbm.2013.01.02110.1016/j.jmbbm.2013.01.021 ↗
22. 10.1016/j.actamat.2013.10.01710.1016/j.actamat.2013.10.017 ↗
23. 10.1007/s11661-018-4771-410.1007/s11661-018-4771-4 ↗
24. 10.1016/j.jmbbm.2019.10349610.1016/j.jmbbm.2019.103496 ↗
25. 10.1007/s00170-016-9429-z10.1007/s00170-016-9429-z ↗
26. 10.1016/j.jnucmat.2015.12.03410.1016/j.jnucmat.2015.12.034 ↗
27. 10.1016/j.scriptamat.2019.10.00510.1016/j.scriptamat.2019.10.005 ↗
28. 10.1038/nmat502110.1038/nmat5021 ↗
29. 10.1016/j.msea.2016.01.05810.1016/j.msea.2016.01.058 ↗
30. 10.1016/j.msea.2019.13827010.1016/j.msea.2019.138270 ↗
31. 10.1016/j.jallcom.2020.15505510.1016/j.jallcom.2020.155055 ↗
32. 10.1016/S0013-4686(01)00679-X10.1016/S0013-4686(01)00679-X ↗
33. 10.1016/j.jallcom.2016.12.20910.1016/j.jallcom.2016.12.209 ↗
34. 10.1016/j.addma.2020.10179210.1016/j.addma.2020.101792 ↗
35. 10.1016/j.scriptamat.2012.06.01410.1016/j.scriptamat.2012.06.014 ↗
36. 10.1016/j.pmatsci.2017.10.00110.1016/j.pmatsci.2017.10.001 ↗
37. 10.1016/j.msea.2016.03.03610.1016/j.msea.2016.03.036 ↗
38. 10.1016/j.jmst.2016.06.01610.1016/j.jmst.2016.06.016 ↗
39. 10.1007/s11661-014-2218-010.1007/s11661-014-2218-0 ↗
40. 10.1016/j.dental.2020.10.02010.1016/j.dental.2020.10.020 ↗
41. 10.1016/j.matdes.2020.10907610.1016/j.matdes.2020.109076 ↗
42. 10.1007/s12540-018-0164-x10.1007/s12540-018-0164-x ↗
43. 10.1016/j.wear.2019.04.00110.1016/j.wear.2019.04.001 ↗
44. 10.1002/adma.20060227610.1002/adma.200602276 ↗
45. ASTM F1537-20, ASTM Standard Specification for Wrought Cobalt-28Chromium-6Molybdenum Alloys for Surgical Implants (UNS R31537, UNS R31538, and UNS R31539); ASTM International, 2020.
46. ASTM F75-18: Standard Specification for Cobalt-28 Chromium-6 Molybdenum Alloy Castings and Casting Alloy for Surgical Implants (UNS R30075); ASTM International, 2018; pp 1–5.