Triple-Configurational Magnetic Robot for Targeted Drug Delivery and Sustained Release
Source abstract
Abstract
Active targeted therapy for bowel cancer using untethered microrobots has attracted extensive attention. However, traditional microrobots face challenges, such as issues of mobility, biocompatibility, drug loading, sustained-release capabilities, and targeting accuracy. Here, we propose an untethered triple-configurational magnetic robot (TCMR) that is composed of three geometrically nested parts: actuation and guarding, anchoring and seeding, and drug release part. A targeting magnetic driving system actuates the TCMR along the predetermined trajectory to the target position. The pH-sensitive actuation and guarding part formed by electrodeposition is degraded in the intestinal environment and separates from the two other parts. A majority of magnetic nanoparticles encapsulated in this part are retrieved. The anchoring and seeding part anchors the lesion area and seeds the drug release part in the gaps of intestinal villi by hydrolysis. Ultimately, the drug release part containing the therapeutic completes the sustained release to prolong the duration of the therapeutic agent. Cytotoxicity and therapeutic tests reveal that TCMRs are biocompatible and suitable for targeted therapy and have good therapeutic performance. The newly designed TCMR will provide new ideas for targeted therapy, thus expanding the application scope of robotics technology in the biomedical field.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Micro and Nano Robotics · Nanoparticle-Based Drug Delivery · Advanced Materials and Mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
State Key Laboratory of Robotics and Systems, Harbin Institute of Technology, 2 Yikuang, Harbin 150080, China
Funding
Ministry of Science and Technology of the People's Republic of China · State Key Laboratory of Robotics and System · National Natural Science Foundation of China
References (42)
Show source-provided references
1. 10.1016/j.ctrv.2020.10202110.1016/j.ctrv.2020.102021 ↗
2. 10.1016/j.ijbiomac.2020.04.07410.1016/j.ijbiomac.2020.04.074 ↗
3. 10.1038/3510216710.1038/35102167 ↗
4. 10.1038/s41598-020-61402-710.1038/s41598-020-61402-7 ↗
5. 10.1038/nrd436310.1038/nrd4363 ↗
6. 10.1002/adhm.20200103110.1002/adhm.202001031 ↗
7. 10.1016/j.biomaterials.2017.07.01310.1016/j.biomaterials.2017.07.013 ↗
8. 10.1002/bit.26022050410.1002/bit.260220504 ↗
9. 10.1016/j.addr.2016.05.01210.1016/j.addr.2016.05.012 ↗
10. 10.1002/smll.20190690810.1002/smll.201906908 ↗
11. 10.1016/j.apmt.2020.10058310.1016/j.apmt.2020.100583 ↗
12. 10.1021/acs.langmuir.9b0389210.1021/acs.langmuir.9b03892 ↗
13. 10.3389/fchem.2019.0040810.3389/fchem.2019.00408 ↗
14. 10.1038/ncomms412410.1038/ncomms4124 ↗
15. 10.1002/adfm.20191032310.1002/adfm.201910323 ↗
16. 10.1016/j.apsb.2019.07.00310.1016/j.apsb.2019.07.003 ↗
17. 10.1038/s41573-018-0005-010.1038/s41573-018-0005-0 ↗
18. 10.1021/acsami.1c0174210.1021/acsami.1c01742 ↗
19. 10.1039/D0TB02384A10.1039/D0TB02384A ↗
20. 10.1038/s41467-019-12679-410.1038/s41467-019-12679-4 ↗
21. 10.1007/BF0206418410.1007/BF02064184 ↗
22. 10.1016/j.lfs.2019.01.05610.1016/j.lfs.2019.01.056 ↗
23. 10.1002/adma.20070197510.1002/adma.200701975 ↗
24. 10.1007/s10544-016-0135-210.1007/s10544-016-0135-2 ↗
25. 10.1002/advs.20180080710.1002/advs.201800807 ↗
26. Iacovacci, V.; Ricotti, L.; Signore, G.; Vistoli, F.; Sinibaldi, E.; Menciassi, A. Retrieval of Magnetic Medical Microrobots From the Bloodstream, International Conference on Robotics and Automation (ICRA), IEEE, Montreal, QC, 2019; pp 2495–2501.10.1109/ICRA.2019.8794322 ↗
27. 10.1002/adhm.20200011810.1002/adhm.202000118 ↗
28. 10.1002/jbm.a.3246610.1002/jbm.a.32466 ↗
29. 10.1016/j.ijbiomac.2015.09.06410.1016/j.ijbiomac.2015.09.064 ↗
30. 10.3109/1061186X.2015.108635910.3109/1061186X.2015.1086359 ↗
31. 10.1002/adv.2193810.1002/adv.21938 ↗
32. 10.1016/j.ijbiomac.2020.06.24010.1016/j.ijbiomac.2020.06.240 ↗
33. 10.2147/VHRM.S5053610.2147/VHRM.S50536 ↗
34. 10.1016/j.ijbiomac.2016.09.11010.1016/j.ijbiomac.2016.09.110 ↗
35. 10.1038/natrevmats.2016.7110.1038/natrevmats.2016.71 ↗
36. 10.1007/s10856-012-4759-310.1007/s10856-012-4759-3 ↗
37. 10.1016/j.bej.2009.12.01210.1016/j.bej.2009.12.012 ↗
38. 10.1016/S0169-409X(97)00124-510.1016/S0169-409X(97)00124-5 ↗
39. 10.1246/cl.17000310.1246/cl.170003 ↗
40. 10.1002/adfm.20110196310.1002/adfm.201101963 ↗
41. 10.1016/j.eurpolymj.2020.11012610.1016/j.eurpolymj.2020.110126 ↗
42. 10.1016/j.mechatronics.2021.10249810.1016/j.mechatronics.2021.102498 ↗