Evaluation of Graphene as a Novel Bioactive Stent Coating: Comparative Performance and Vascular Response in Porcine Coronary Arteries
Source abstract
Abstract
Coronary drug-eluting stents (DESs) are the current clinical standard, yet delayed endothelialization remains a critical challenge. Graphene-based coatings have emerged as promising cardiovascular biomaterials due to their favorable hemocompatibility and ability to support endothelial cell growth. In this study, we evaluated the in vivo performance of graphene-coated stents (GCSs) compared with commercial sirolimus-eluting stents in a Polish White swine model (n = 10). Stents were implanted into major coronary branches, with follow-up at 30 and 90 days using quantitative coronary angiography (QCA), optical coherence tomography (OCT), and cryogenic scanning electron microscopy (cryo-SEM). No systemic toxicity, mortality, thrombotic events, or ischemic complications were observed during the study period. QCA demonstrated no significant differences in percent diameter stenosis between GCSs and DESs at either 30 days (12.3 ± 6.1% vs. 8.6 ± 5.8%, p = 0.2782) or 90 days (18.3 ± 10.5% vs. 9.6 ± 6.6%, p = 0.1074). OCT analysis confirmed comparable lumen and neointimal parameters between groups, while demonstrating a favorable, although non-significant, trend toward a lower percentage of uncovered struts in GCSs. Cryo-SEM imaging demonstrated stable tissue integration and a preserved healing response surrounding GCSs. Collectively, these findings indicate that GCSs are safe and biocompatible and demonstrate mid-term vascular performance comparable to clinically used DES platforms. The presented results support further investigation of graphene-based coatings as potential surface-modification strategies for coronary stents.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Graphene and Nanomaterials Applications · Electrospun Nanofibers in Biomedical Applications · Nanoparticles: synthesis and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Pre-Clinical Research Center, Wrocław Medical University, K. Marcinkowskiego 1, 50-368 Wrocław, Poland
Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wrocław University of Science and Technology, Wybrzeże S. Wyspiańskiego 27, 50-370 Wrocław, Poland
Department of Diagnostics and Clinical Sciences, Faculty of Veterinary Medicine, University of Agriculture in Kraków, Aleja A. Mickiewicza 21, 31-120 Kraków, Poland
Funding
Wroclaw Medical University
References (37)
Show source-provided references
1. Innovations in interventional cardiology: Pioneering techniques for a new era10.1016/j.cpcardiol.2024.102836 ↗
2. Epidemiology and the Magnitude of Coronary Artery Disease and Acute Coronary Syndrome: A Narrative Review10.2991/jegh.k.201217.001 ↗
3. Evolutionary perspective of drug eluting stents: From thick polymer to polymer free approach10.1186/s13019-022-01812-y ↗
4. Surface Engineering of Cardiovascular Devices for Improved Hemocompatibility and Rapid Endothelialization10.1002/adhm.202000920 ↗
5. Biomimetic cardiovascular stents for in vivo re-endothelialization10.1016/j.biomaterials.2016.06.042 ↗
6. Strohbach, A., and Busch, R. (2021). Predicting the In Vivo Performance of Cardiovascular Biomaterials: Current Approaches In Vitro Evaluation of Blood–Biomaterial Interactions. Int. J. Mol. Sci., 22.10.3390/ijms222111390 ↗
7. Surface engineering at the nanoscale: A way forward to improve coronary stent efficacy10.1063/5.0037298 ↗
8. Raikar, A.S., Priya, S., Bhilegaonkar, S.P., Somnache, S.N., and Kalaskar, D.M. (2023). Surface Engineering of Bioactive Coatings for Improved Stent Hemocompatibility: A Comprehensive Review. Materials, 16.10.20944/preprints202310.0470.v1 ↗
9. Safety and Efficacy of Polymer-Free Drug-Eluting Stents10.1161/CIRCINTERVENTIONS.118.007311 ↗
10. Functionalization with a VEGFR2-binding antibody fragment leads to enhanced endothelialization of a cardiovascular stent in vitro and in vivo10.1002/jbm.b.34380 ↗
11. In vitro examinations of the anti-inflammatory interleukin functionalized polydopamine based biomaterial as a potential coating for cardiovascular stents10.1016/j.bbe.2023.02.001 ↗
12. Functionalized CD133 antibody coated stent surface simultaneously promotes EPCs adhesion and inhibits smooth muscle cell proliferation–A novel approach to prevent in-stent restenosis10.1016/j.colsurfb.2018.11.061 ↗
13. Late Endothelial Progenitor Cell-Capture Stents with CD146 Antibody and Nanostructure Reduce In-Stent Restenosis and Thrombosis10.1016/j.actbio.2020.05.011 ↗
14. Benjamin, S.R., and Júnior, E.J.M.R. (2024). Carbon-based nanomaterials as antimicrobial nanocoatings for medical devices and implants. Next-Generation Antimicrobial Nanocoatings for Medical Devices and Implants, Woodhead Publishing.10.1016/B978-0-323-95756-4.00012-9 ↗
15. Graphene coatings for enhanced hemo-compatibility of nitinol stents10.1039/C2RA23073A ↗
16. Biocompatible Carbon-Based Coating as Potential Endovascular Material for Stent Surface
17. Innovative coating based on graphene and their decorated nanoparticles for medical stent applications10.1016/j.msec.2018.11.084 ↗
18. Yang, M.-C., Tsou, H.-M., Hsiao, Y.-S., Cheng, Y.-W., Liu, C.-C., Huang, L.-Y., Peng, X.-Y., Liu, T.-Y., Yung, M.-C., and Hsu, C.-C. (2019). Electrochemical Polymerization of PEDOT–Graphene Oxide–Heparin Composite Coating for Anti-Fouling and Anti-Clotting of Cardiovascular Stents. Polymers, 11.10.3390/polym11091520 ↗
19. Anticoagulation and endothelial cell behaviors of heparin-loaded graphene oxide coating on titanium surface10.1016/j.msec.2016.03.001 ↗
20. Inhibition of in-stent restenosis after graphene oxide double-layer drug coating with good biocompatibility10.1093/rb/rbz010 ↗
21. Wasyluk, Ł., Hreniak, D., Boiko, V., Sobieszczańska, B., Bologna, E., Zingales, M., Pasławski, R., Arkowski, J., Sareło, P., and Wawrzyńska, M. (2024). Functional Mechanical Behavior and Biocompatible Characteristics of Graphene-Coated Cardiovascular Stents. Int. J. Mol. Sci., 25.10.3390/ijms252413345 ↗
22. The effects of stenting on coronary endothelium from a molecular biological view: Time for improvement?10.1111/jcmm.13936 ↗
23. Gherasie, F.-A., Valentin, C., and Busnatu, S.-S. (2023). Is There an Advantage of Ultrathin-Strut Drug-Eluting Stents over Second- and Third-Generation Drug-Eluting Stents?. J. Pers. Med., 13.10.3390/jpm13050753 ↗
24. Shen, Y., Yu, X., Cui, J., Yu, F., Liu, M., Chen, Y., Wu, J., Sun, B., and Mo, X. (2022). Development of Biodegradable Polymeric Stents for the Treatment of Cardiovascular Diseases. Biomolecules, 12.10.3390/biom12091245 ↗
25. Magmaris Resorbable Magnesium Scaffold Versus Conventional Drug-Eluting Stent in ST-Segment Elevation Myocardial Infarction: 1-Year Results of a Propensity-Score-Matching Comparison10.1016/j.carrev.2022.05.028 ↗
26. Comparison of an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent for the treatment of coronary artery stenosis (ABSORB II): A 3 year, randomised, controlled, single-blind, multicentre clinical trial10.1016/S0140-6736(16)32050-5 ↗
27. Long-term efficacy and safety of drug-coated balloons versus drug-eluting stents for small coronary artery disease (BASKET-SMALL 2): 3-year follow-up of a randomised, non-inferiority trial10.1016/S0140-6736(20)32173-5 ↗
28. Stepwise dual antiplatelet therapy de-escalation in patients after drug coated balloon angioplasty (REC-CAGEFREE II): Multicentre, randomised, open label, assessor blind, non-inferiority trial10.1136/bmj-2024-082945 ↗
29. Indications for Use of Drug-Coated Balloons in Coronary Intervention: Academic Research Consortium Position Statement10.1016/j.jacc.2025.07.049 ↗
30. Synergistic fusion of CD47, VE-cadherin and mussel adhesion protein promotes endothelialization and suppresses inflammation in vascular stents
31. Characterization of carotid endothelial cell proliferation on Au, Au/GO, and Au/rGO surfaces by electrical impedance spectroscopy10.1007/s11517-020-02166-0 ↗
32. Mechanical and physio-biological properties of peptide-coated stent for re-endothelialization10.1186/s40824-020-0182-x ↗
33. A CO-releasing coating based on carboxymethyl chitosan-functionalized graphene oxide for improving the anticorrosion and biocompatibility of magnesium alloy stent materials10.1016/j.ijbiomac.2024.132487 ↗
34. Synthesis and characterization of amine-functionalized graphene as a nitric oxide-generating coating for vascular stents10.1063/5.0192379 ↗
35. Long-term safety of an everolimus-eluting bioresorbable vascular scaffold and the cobalt-chromium XIENCE V stent in a porcine coronary artery model10.1161/CIRCINTERVENTIONS.113.000990 ↗
36. Two-year longitudinal evaluation of a second-generation thin-strut sirolimus-eluting bioresorbable coronary scaffold with hybrid cell design in porcine coronary arteries10.5603/CJ.a2018.0095 ↗
37. Intracoronary Optical Coherence Tomography and Histology of Overlapping Everolimus-Eluting Bioresorbable Vascular Scaffolds in a Porcine Coronary Artery Model: The Potential Implications for Clinical Practice10.1016/j.jcin.2012.12.131 ↗