journal article·2026-04-17Open access

Accuracy of Static Computer-Aided Implant Surgery: A Clinical Comparison of Tooth-, Bone-, and Mucosa-Supported Surgical Guides

Igor Smojver, Roko Bjelica, Marko Vuletić, Luka Stojić, Vlatka Njari Galić, Dragana Gabrić

Abstract

The accuracy of static computer-aided implant surgery (s-CAIS) is fundamental for predictable clinical outcomes. The objective of this study was to evaluate the influence of different guide-support modalities on the linear and angular accuracy of implant placement. In this retrospective clinical investigation conducted at a single specialty hospital, a total of 180 implants were analyzed, divided into three equal groups (n = 60) based on the guide support type: tooth-supported, bone-supported, and mucosa-supported. Accuracy was assessed by superimposing preoperative virtual plans with postoperative cone-beam computed tomography (CBCT) scans, measuring linear deviations at the neck and apex of the implant, as well as angular discrepancies. The type of guide support was found to be a significant factor associated with surgical accuracy (p < 0.001). Tooth-supported guides demonstrated the highest level of accuracy, with a mean angular deviation of 1.81° ± 0.45° and linear deviations at the neck and apex of 0.59 ± 0.18 mm and 0.73 ± 0.19 mm, respectively. These were followed by bone-supported guides (2.14° ± 0.48°; 1.04 ± 0.26 mm; 1.61 ± 0.31 mm), while mucosa-supported guides exhibited the greatest deviations (2.95° ± 0.60°; 1.47 ± 0.29 mm; 1.87 ± 0.37 mm). Significant intergroup differences and large effect sizes were observed, particularly regarding angular and horizontal discrepancies. These findings demonstrate a distinct gradient of accuracy based on guide support, establishing tooth-supported guides as the most accurate, followed by bone-supported and, lastly, mucosa-supported guides. While all modalities are clinically applicable, the use of mucosa-supported guides necessitates increased safety margins to account for the increased risk of linear and angular discrepancies inherent to mucosal tissue displacement.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Orthodontics and Dentofacial Orthopedics · Dental Radiography and Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Oral Surgery, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia

St. Catherine Specialty Hospital, 10000 Zagreb, Croatia

Department of Dental Medicine, Clinical Hospital Centre Zagreb, 10000 Zagreb, Croatia

Private Practice DentA Centar, 10000 Zagreb, Croatia

Mund-Kiefer-Gesichtschirurgie Steffen Wirth, 82538 Geretsried, Germany

Funding

National Recovery and Resilience Plan · Evaluation of Innovative and Standard Protocols in Endodontic and Surgical Therapy

References (30)

Show source-provided references
1. Computer Technology Applications in Surgical Implant Dentistry: A Systematic Review10.11607/jomi.2014suppl.g1.2 ↗
2. Accuracy of Computer-Guided Surgery for Dental Implant Placement in Fully Edentulous Patients: A Systematic Review10.4103/ejd.ejd_249_17 ↗
3. The Accuracy of Static Computer-Aided Implant Surgery: A Systematic Review and Meta-Analysis10.1111/clr.13346 ↗
4. Depth Distortion and Angular Deviation of a Fully Guided Tooth-supported Static Surgical Guide in a Partially Edentulous Patient: A Systematic Review and Meta-analysis10.1111/jopr.13893 ↗
5. Current State of the Art of Computer-Guided Implant Surgery10.1111/prd.12175 ↗
6. A Comparative Retrospective Study of Different Surgical Guide Designs for Static Computer-assisted Implant Surgery in Posterior Single Edentulous Sites10.1111/clr.13858 ↗
7. Azevedo, M., Correia, F., and Faria Almeida, R. (2024). Accuracy of Implant Guided Surgery in Fully Edentulous Patients: Prediction vs. Actual Outcome—Systematic Review. J. Clin. Med., 13.10.3390/jcm13175178 ↗
8. Accuracy of Guided Surgery via Stereolithographic Mucosa-Supported Surgical Guide in Implant Surgery for Edentulous Patient: A Systematic Review10.5037/jomr.2018.9101 ↗
9. Khaohoen, A., Powcharoen, W., Sornsuwan, T., Chaijareenont, P., Rungsiyakull, C., and Rungsiyakull, P. (2024). Accuracy of Implant Placement with Computer-Aided Static, Dynamic, and Robot-Assisted Surgery: A Systematic Review and Meta-Analysis of Clinical Trials. BMC Oral Health, 24.10.1186/s12903-024-04033-y ↗
10. Accuracy Comparison of Guided Surgery for Dental Implants According to the Tissue of Support: A Systematic Review and Meta-analysis10.1111/clr.12841 ↗
11. A Systematic Review of the Accuracy of Digital Surgical Guides for Dental Implantation10.1186/s40729-023-00507-w ↗
12. Rattan, S., Sabu, A.M., Varghese, K.G., and Kurian, N. (2026). Accuracy of Implant Placement Using Surgical Guides in Edentulous Patients: A Systematic Review and Meta-Analysis. Int. J. Oral Maxillofac. Surg., S0901-5027(26)00088-3. online ahead of print.10.1016/j.ijom.2026.03.004 ↗
13. Implant Surgery Using Bone- and Mucosa-supported Stereolithographic Guides in Totally Edentulous Jaws: Surgical and Post-operative Outcomes of Computer-aided vs. Standard Techniques10.1111/j.1600-0501.2010.01957.x ↗
14. Bjelica, R., Smojver, I., Stojić, L., Vuletić, M., Katanec, T., and Gabrić, D. (2026). Accuracy of Fully Guided Implant Placement Using Bone-Supported Stackable Surgical Guides in Completely Edentulous Patients—A Retrospective Study. J. Clin. Med., 15.10.3390/jcm15020652 ↗
15. Influence of Surgical Guide Support and Implant Site Location on Accuracy of Static Computer-Assisted Implant Surgery10.1111/clr.13520 ↗
16. Markiewicz, M., and Nowicki, A. (2025). Accuracy of Computer-Guided Dental Implant Placement: A Clinical Comparison of Three Surgical Guide Types. J. Clin. Med., 14.10.3390/jcm14248652 ↗
17. Is There a Learning Curve in Static Computer-Assisted Implant Surgery? A Prospective Clinical Study10.1016/j.ijom.2020.03.007 ↗
18. Accuracy of Two Stereolithographic Guide Systems for Computer-Aided Implant Placement: A Computed Tomography-Based Clinical Comparative Study10.1902/jop.2009.090348 ↗
19. Computer-supported Implant Planning and Guided Surgery: A Narrative Review10.1111/clr.12638 ↗
20. Accuracy of Pin-Supported Surgical Guides for Complete Arch Implant Placement: A Comparison with Conventional Mucosa-Supported Guides10.1016/j.prosdent.2025.11.006 ↗
21. Vinci, R., Manacorda, M., Abundo, R., Lucchina, A.G., Scarano, A., Crocetta, C., Lo Muzio, L., Gherlone, E.F., and Mastrangelo, F. (2020). Accuracy of Edentulous Computer-Aided Implant Surgery as Compared to Virtual Planning: A Retrospective Multicenter Study. J. Clin. Med., 9.10.3390/jcm9030774 ↗
22. Kernen, F., Kramer, J., Wanner, L., Wismeijer, D., Nelson, K., and Flügge, T. (2020). A Review of Virtual Planning Software for Guided Implant Surgery—Data Import and Visualization, Drill Guide Design and Manufacturing. BMC Oral Health, 20.10.1186/s12903-020-01208-1 ↗
23. Comparison between Computer-Guided and Freehand Dental Implant Placement Surgery: A Systematic Review and Meta-Analysis10.1016/j.ijom.2020.08.004 ↗
24. Proceedings of the 6th ITI Consensus Conference10.1111/clr.13301 ↗
25. Accuracy Assessment of Dynamic Computer–Aided Implant Placement: A Systematic Review and Meta-Analysis10.1007/s00784-021-03833-8 ↗
26. Accuracy of Computer-Aided Oral Implant Surgery: A Clinical and Radiographic Study
27. Accuracy of Implant Placement with Computer-Guided Surgery: A Systematic Review and Meta-Analysis Comparing Cadaver, Clinical, and In Vitro Studies10.11607/jomi.5556 ↗
28. A Randomized Controlled Study on the Accuracy of Free-handed, Pilot-drill Guided and Fully Guided Implant Surgery in Partially Edentulous Patients10.1111/jcpe.12897 ↗
29. The Accuracy of Different Dental Impression Techniques for Implant-supported Dental Prostheses: A Systematic Review and Meta-analysis10.1111/clr.13273 ↗
30. Association between Ridge Morphology and Complexity of Implant Placement Planning in the Posterior Mandible10.1016/j.prosdent.2020.07.034 ↗