Retrievability of Fractured Abutment Screws in Dental Implants Using Three Removal Techniques: An In Vitro Pilot Study
Source abstract
Abstract
Introduction: The fracturing of abutment screws is a recurrent technical complication in implant-supported prostheses that may compromise prosthetic maintenance. Although multiple retrieval approaches have been described, comparative data under controlled experimental conditions remain limited. Materials and Methods: This in vitro pilot study evaluated the retrievability of fractured abutment screws when using three commonly applied instruments: an ultrasonic scaler, a fissure bur, and a screw removal kit. Eighteen implants from a single implant system were embedded in epoxy resin, and abutment screws were fractured under clockwise monotonic torque either with (w/A) or without (w/oA) abutments (n= 3 per retrieval method). Retrieval success and procedure time were recorded. Scanning electron microscopy (SEM) was performed to qualitatively assess deformation of the implant internal hex and screw thread morphology. Results: Fracture torque values were higher in specimens fractured with abutments compared with those without abutments. Fractures induced without abutments appeared to extend deeper within the screw channel, engaging a greater number of internal threads. In this pilot study, a shorter retrieval time was observed with the screw removal kit and fissure bur compared with the ultrasonic scaler, although retrieval outcomes varied between specimens. SEM observations suggested differing patterns of internal hex deformation between the retrieval techniques. Conclusions: Within the limitations of this in vitro pilot study, different retrieval approaches demonstrated characteristic mechanical behaviors and deformation patterns in the implant internal connection. These preliminary findings provide descriptive insight into the retrievability of fractured screws and may serve as a basis for future studies with larger sample sizes and clinically relevant fracture models.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Facial Trauma and Fracture Management · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Dentistry, Far Eastern Memorial Hospital, New Taipei City 220216, Taiwan
Department of Dentistry, Kaohsiung Medical University, Kaohsiung City 807378, Taiwan
Funding
Far Eastern Memorial Hospital and National Taiwan University of Taiwan
References (30)
Show source-provided references
1. Clinical complications with implants and implant prostheses10.1016/S0022-3913(03)00212-9 ↗
2. Improvements in implant dentistry over the last decade: Comparison of survival and complication rates in older and newer publications10.11607/jomi.2014suppl.g5.2 ↗
3. Cho, S.-M., Byun, S.-H., Ahn, S.-Y., Han, H.-S., On, S.-W., Park, S.-Y., Yi, S.-M., Park, I.-Y., Yang, B.-E., and Kim, L.-K. (2025). Biomechanical Evaluation of a Novel Non-Engaging Abutment and Screw in Internal Implant Systems: Comparative Fatigue and Load Testing. J. Funct. Biomater., 16.10.3390/jfb16030107 ↗
4. Pantaleo, G., Acerra, A., Giordano, F., D’Ambrosio, F., Langone, M., and Caggiano, M. (2022). Immediate Loading of Fixed Prostheses in Fully Edentulous Jaws: A 7-Year Follow-Up from a Single-Cohort Retrospective Study. Appl. Sci., 12.10.3390/app122312427 ↗
5. Four-year post-loading results of full-arch rehabilitation with immediate placement and immediate loading implants: A retrospective controlled study
6. Fracture mechanisms of retrieved titanium screw thread in dental implant10.1016/S0142-9612(01)00380-5 ↗
7. Vinhas, A.S., Aroso, C., Salazar, F., López-Jarana, P., Ríos-Santos, J.V., and Herrero-Climent, M. (2020). Review of the mechanical behavior of different implant–abutment connections. Int. J. Environ. Res. Public Health, 17.10.3390/ijerph17228685 ↗
8. Implant screw mechanics and the settling effect: An overview10.1563/1548-1336(2003)029<0242:ISMATS>2.3.CO;2 ↗
9. SEM and fractography analysis of screw thread loosening in dental implants10.1177/039463200702001s05 ↗
10. Prosthetic failures in dental implant therapy10.1111/prd.12416 ↗
11. Occurrence and clustering of complications in implant dentistry10.1111/clr.13647 ↗
12. Survival and complications: A 9-to 15-year retrospective follow-up of dental implant therapy10.1111/joor.12866 ↗
13. Fracture strength of zirconia implant abutments on narrow diameter implants with internal and external implant abutment connections: A study on the titanium resin base concept10.1111/clr.13139 ↗
14. In Vitro Evaluation of Three Methods for the Retrieval of Fractured Screw Fragments from Dental Implants10.11607/jomi.5174 ↗
15. Hollow abutment screw design for easy retrieval in case of screw fracture in dental implant system10.1155/2017/4842072 ↗
16. Martínez-Alcaraz, P., Flores-Fraile, J., Agustín-Panadero, R., Senent-Vicente, G., Gómez-Polo, C., de la Cruz-Jiménez, S., Zubizarreta-Macho, Á., and Lobo Galindo, A.B. (2024). Retrievability of Fractured Abutment Screws and Damage to Implant–Abutment Connections: An In Vitro Comparative Analysis of Conventional vs. Drilling Techniques. Appl. Sci., 14.10.3390/app142411846 ↗
17. Influence of the implant-abutment connection design and diameter on the screw joint stability10.4047/jap.2014.6.2.126 ↗
18. Biological factors contributing to failures of osseointegrated oral implants (I). success criteria and epidemiology10.1046/j.0909-8836..t01-2-.x ↗
19. Factors associated with early and late failure of dental implants10.1111/j.2041-1626.2012.00162.x ↗
20. Load fatigue performance evaluation on two internal tapered abutment–implant connection implants under different screw tightening torques10.1563/aaid-joi-D-16-00129 ↗
21. Mechanism of and factors associated with the loosening of the implant abutment screw: A review10.1111/jerd.12494 ↗
22. Prosthetic complications with implant prostheses
23. Measurements of repeated tightening and loosening torque of seven different implant/abutment connection designs and their modifications: An in vitro study10.1111/jopr.12467 ↗
24. Jeng, M.-D., Lin, Y.-S., and Lin, C.-L. (2020). Biomechanical evaluation of the effects of implant neck wall thickness and abutment screw size: A 3D nonlinear finite element analysis. Appl. Sci., 10.10.3390/app10103471 ↗
25. Non-linear 3D evaluation of different oral implant-abutment connections10.1177/0022034512463396 ↗
26. Changes in the abutment-implant interface in Morse taper implant connections after mechanical cycling: A pilot study10.11607/jomi.3113 ↗
27. The micromechanical behavior of implant-abutment connections under a dynamic load protocol10.1111/cid.12651 ↗
28. The influence of the connection, length and diameter of an implant on bone biomechanics10.3109/00016357.2014.961957 ↗
29. The influence of implant-abutment connection to peri-implant bone loss: A systematic review and meta-analysis10.1111/cid.12620 ↗
30. Neji, G., Gasparro, R., Tlili, M., Dhahri, A., Khanfir, F., Sammartino, G., Aliberti, A., Campana, M.D., and Ben Amor, F. (2026). AI-Powered Predictive Models in Implant Dentistry: Planning, Risk Assessment, and Outcomes. J. Clin. Med., 15.10.3390/jcm15010228 ↗