journal article·2026-02-08Open access

Comparative Finite Element Evaluation of Polymeric and Metallic Bioresorbable Sinus Stents Under Quasi-Static Radial Compression

Wenyu Fu, Aiping Yang, Aike Qiao

Abstract

To address the issues of displacement and insufficient positional stability observed in the clinical use of the PROPEL Mini stent, this study investigates the influence of different biodegradable materials on the mechanical properties of the stent under the constraint of a fixed monofilament braided closed-loop geometry. Finite element analyses are conducted using Abaqus/Explicit to quantitatively evaluate the nonlinear mapping between nominal diameter, axial length, and radial pressure throughout a loading–unloading cycle. The results reveal that while axial behavior is consistent during compression, material-specific plasticity causes irreversible geometric sets in Mg alloy and PLGA models, whereas the PCL stent achieves total elastic recovery to its initial dimensions. During unloading, the Mg alloy stent recovers to a nominal diameter of 28 mm with a reduced axial length of approximately 22 mm, whereas the PLGA stent exhibits a much smaller recovery diameter of 14 mm with an axial length of approximately 23 mm. These post-release configurations directly determine the functional expansion range of the biodegradable stents after implantation. During unloading, the Mg alloy stent provides the highest radial pressure (peak 6.8 kPa) with a functional recovery range up to 26.5 mm, ensuring superior scaffolding stability. In contrast, while PCL achieves the widest recovery (52 mm), its radial pressure is clinically negligible (the maximum value is still less than 165 Pa), and the PLGA model exhibits both insufficient support and a restricted functional recovery limit (13 mm). By using high-strength materials such as Mg alloys, the radial anchoring force of the stent can be effectively enhanced without changing the existing structure, providing a scientific basis for solving clinical displacement problems.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Magnesium Alloys: Properties and Applications · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

College of Robotics, Beijing Union University, Beijing 100027, China

Beijing Engineering Research Center of Smart Mechanical Innovation Design Service, Beijing 100027, China

College of Chemistry and Life Science, Beijing University of Technology, Beijing 100124, China

Beijing International Science and Technology Cooperation Base for Intelligent Physiological Measurement and Clinical Transformation, Beijing 100124, China

Funding

National Natural Science Foundation of China · Beijing Union University’s Top 100 Talents Program

References (33)

Show source-provided references
1. Evaluation of the PROPEL® mini sinus implant for the treatment of frontal sinus disease10.1080/17425247.2016.1250740 ↗
2. Effect of steroid-releasing sinus implants on postoperative medical and surgical interventions: An efficacy meta-analysis10.1002/alr.21044 ↗
3. Complications associated with PROPEL mometasone furoate bioabsorbable drug-eluting sinus stents from 2012 to 202010.1177/19458924211035641 ↗
4. Management of the middle turbinate during and after sinus surgery
5. A thermoresponsive hydrogel system for long-acting corticosteroid delivery into the paranasal sinuses10.1016/j.jconrel.2020.10.062 ↗
6. Drug-eluting implants in chronic rhinosinusitis: An evidence-based review with recommendations10.1002/alr.22565 ↗
7. Adverse events associated with corticosteroid-eluting sinus stents: A MAUDE database analysis10.1177/01945998211006930 ↗
8. Biomechanical characteristics of self-expanding sinus stents during crimping and deployment_A comparison between different biomaterials10.1016/j.jmbbm.2023.105669 ↗
9. A review of biodegradable biliary stents made of magnesium metals: Current progress and future trends10.1016/j.jma.2024.11.014 ↗
10. Ayechu-Abendaño, A., Pérez-Jiménez, A., Sánchez-Matás, C., López-Villalobos, J.L., Díaz-Jiménez, C., Fernández-Parra, R., and Malvè, M. (2024). Computational analysis of polymeric biodegradable and customizable airway stent designs. Polymers, 16.10.3390/polym16121691 ↗
11. A finite element strategy to investigate the free expansion behavior of a biodegradable polymeric stent10.1016/j.jbiomech.2015.03.024 ↗
12. A study of the geometrical and mechanical properties of a self-expanding metallic stent—Theory and experiment10.1002/jab.770040111 ↗
13. Numerical investigations of the mechanical properties of braided vascular stents
14. Experimental mechanical testing of Poly (l-Lactide) (PLLA) to facilitate preegradation characteristics for application in cardiovascular stenting10.1016/j.polymertesting.2016.07.011 ↗
15. Finite element analyses for design evaluation of biodegradable magnesium alloy stents in arterial vessels10.1016/j.mseb.2011.03.013 ↗
16. Yu, H., Zheng, L., Qiu, J., Wang, J., Xu, Y., Fan, B., Li, R., Liu, J., Wang, C., and Fan, Y. (2022). Mechanical property analysis and design parameter optimization of a novel nitinol nasal stent based on numerical simulation. Front. Bioeng. Biotechnol., 10.10.3389/fbioe.2022.1064605 ↗
17. Computer modeling of deployment and mechanical expansion of neurovascular flow diverter in patient-specific intracranial aneurysms10.1016/j.jbiomech.2012.06.013 ↗
18. Comparative friction of orthodontic wires under dry and wet conditions10.1016/0002-9416(86)90006-0 ↗
19. Carotid artery stenting simulation: From patient-specific images to finite element analysis10.1016/j.medengphy.2010.10.011 ↗
20. Finite element analysis of transcatheter aortic valve implantation: Insights on the modelling of self-expandable devices10.1016/j.jmbbm.2021.104772 ↗
21. Finite element shape optimization for biodegradable magnesium alloy stents10.1007/s10439-010-0057-8 ↗
22. A promising biodegradable magnesium alloy suitable for clinical vascular stent application10.1038/srep46343 ↗
23. Multiple bioabsorbable corticosteroid-eluting stent placement with associated skull base injury10.1002/lary.27659 ↗
24. Performance characteristics of self-expanding peripheral nitinol stents10.1055/s-0028-1109108 ↗
25. Fabrication and characterization of bioresorbable radiopaque PLLA/PCL/Mg alloy composite tubes for cardiovascular stent application10.1080/00914037.2023.2182783 ↗
26. Posterior ethmoid sinus: A computed tomography analysis and classification10.1186/s43163-022-00248-4 ↗
27. Frontal sinus surgery 2004: Update of clinical anatomy and surgical techniques10.1053/j.otot.2004.02.004 ↗
28. Evaluation of the stress relaxation behavior of poly (L-lactic acid) self-expanding braided stents10.1002/pat.6199 ↗
29. Novel application of steroid eluting stent in petrous apex cholesterol granuloma
30. Bergström, J.S. (2015). Theory and Computational Modeling. Mechanics of Solid Polymers, Chenango County. [1st ed.].
31. Physical and mechanical degradation behaviour of semi-crystalline PLLA for bioresorbable stent applications10.1016/j.jmbbm.2021.104409 ↗
32. Degryse, O. (2025). Personalized Bioresorbable Sinus Stents for Chronic Rhinosinusitis: Addressing Material, Process and Design Challenges. [Ph.D. Thesis, Catholic University of Leuven].
33. Numerical simulation of stent deployment within patient-specific artery and its validation against clinical data10.1016/j.cmpb.2019.04.005 ↗