Evaluation of the Dimensional Accuracy of 3D-Printed Aligners: An In Vitro Study Using Reverse Engineering Analysis
Source abstract
Abstract
Background: This study aimed to investigate the dimensional deformation that can occur during the fabrication of a 3D-printed aligner made with the TC-85 DAC resin (Graphy Inc., Seoul, Republic of Korea) and determine if the manual removal of the print supports before final aligner curing affects the dimensional accuracy. Methods: 10 subjects with permanent dentition were selected, and a set of aligners was digitally designed using the uDesign Direct Aligner beta software (Graphy Inc., Seoul, Republic of Korea). Each aligner was 3D-printed using TC-85 DAC resin (Graphy Inc., Seoul, Republic of Korea) twice: one copy was produced removing the print supports before final curing, whereas the other was cured with the supports still attached. The aligners were digitized and compared to the original design of the digitally designed aligner using RMS and Inter-second molar distance data to identify variations between 3D-produced aligners and their respective digital design. Results: the comparison between aligners produced in two different ways was statistically significant with a p-value < 0.0001 for both the records used. Conclusions: the manual removal of the print supports before final curing affects the dimensional accuracy of aligners made by direct 3D printing, permanently altering the aligner’s internal geometry, confirming that post-processing conditions significantly affect dimensional stability.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Orthodontics and Dentofacial Orthopedics · Anatomy and Medical Technology
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical and Aerospace Engineering, Polytechnic University of Turin, 10129 Torino, Italy
Specialization School in Orthodontics, Department of Surgical Sciences, Dental School of the University of Torino, 10126 Torino, Italy
Department of Surgical Sciences, Dental School of the University of Torino, 10126 Torino, Italy
Funding
University of Turin
References (26)
Show source-provided references
1. Tartaglia, G.M., Mapelli, A., Maspero, C., Santaniello, T., Serafin, M., Farronato, M., and Caprioglio, A. (2021). Direct 3D Printing of Clear Orthodontic Aligners: Current State and Future Possibilities. Materials, 14.10.3390/ma14071799 ↗
2. The mechanical properties of dental thermoplastic materials in a simulated intraoral environment10.1016/j.odw.2006.03.003 ↗
3. In-house 3D-printed aligners: Effect of in vivo ageing on mechanical properties10.1093/ejo/cjab022 ↗
4. Thermo-mechanical properties of 3D printed photocurable shape memory resin for clear aligners10.1038/s41598-022-09831-4 ↗
5. Comparative analysis of mechanical properties of orthodontic aligners produced by different contemporary 3D printers10.1111/ocr.12537 ↗
6. Force profile assessment of direct-printed aligners versus thermoformed aligners and the effects of non-engaged surface patterns10.1186/s40510-022-00443-2 ↗
7. Cytotoxicity and estrogenicity of a novel 3-dimensional printed orthodontic aligner10.1016/j.ajodo.2022.06.014 ↗
8. Biocompatibility of variable thicknesses of a novel directly printed aligner in orthodontics10.1038/s41598-025-85359-7 ↗
9. Direct 3D printing aligners—Past, present and future possibilities10.1038/s41415-024-7126-0 ↗
10. Comparison of dimensional accuracy between direct-printed and thermoformed aligners10.4041/kjod21.269 ↗
11. Physiochemical and mechanical characterisation of orthodontic 3D printed aligner material made of shape memory polymers (4D aligner material)10.1016/j.jmbbm.2023.106337 ↗
12. Advances in orthodontic clear aligner materials
13. Class II Correction and Crowding Treatment Using In-House Direct Printed Clear Aligners: A Literature Review and Case Report
14. Dizon, J.R.C., Gache, C.C.L., Cascolan, H.M.S., Cancino, L.T., and Advincula, R.C. (2021). Post-Processing of 3D-Printed Polymers. Technologies, 9.10.3390/technologies9030061 ↗
15. Precision of 3D-printed splints with different dental model offsets10.1016/j.ajodo.2018.09.012 ↗
16. Analysis of the thickness of 3-dimensional-printed orthodontic aligners10.1016/j.ajodo.2020.07.029 ↗
17. Wada, J., Wada, K., Gibreel, M., Wakabayashi, N., Iwamoto, T., Vallittu, P.K., and Lassila, L. (2022). Effect of Nitrogen Gas Post-Curing and Printer Type on the Mechanical Properties of 3D-Printed Hard Occlusal Splint Material. Polymers, 14.10.3390/polym14193971 ↗
18. Wada, J., Wada, K., Gibreel, M., Wakabayashi, N., Iwamoto, T., Vallittu, P.K., and Lassila, L. (2022). Effect of 3D Printer Type and Use of Protection Gas during Post-Curing on Some Physical Properties of Soft Occlusal Splint Material. Polymers, 14.10.3390/polym14214618 ↗
19. Effect of heat treatment and nitrogen atmosphere during post-curing on mechanical properties of 3D-printed orthodontic aligners10.1093/ejo/cjad074 ↗
20. Evaluation of the effects of temperature and centrifugation time on elimination of uncured resin from 3D-printed dental aligners10.1038/s41598-024-66150-6 ↗
21. Grassia, V., Ronsivalle, V., Isola, G., Nucci, L., Leonardi, R., and Lo Giudice, A. (2023). Accuracy (trueness and precision) of 3D printed orthodontic models finalized to clear aligners production, testing crowded and spaced dentition. BMC Oral Health, 23.10.1186/s12903-023-03025-8 ↗
22. Determinant factors of Yemeni maxillary arch dimensions10.1016/j.sdentj.2014.08.005 ↗
23. Tsolakis, I.A., Papaioannou, W., Papadopoulou, E., Dalampira, M., and Tsolakis, A.I. (2022). Comparison in Terms of Accuracy between DLP and LCD Printing Technology for Dental Model Printing. Dent. J., 10.10.3390/dj10100181 ↗
24. The effect of layer thıckness on the accuracy of the different ın-house clear alıgner attachments10.1007/s00784-023-05153-5 ↗
25. Boo, H.S., Sivarajan, S., Nor Zahidah Mohd Tahir, N., and Bahar, A.D. (2025). Accuracy of three-dimensionally printed retainers and aligners: A systematic review. Genauigkeit von dreidimensional gedruckten Retainern und Alignern: Eine systematische Überprüfung. J Orofac. Orthop.10.1007/s00056-024-00570-x ↗
26. Effect of print orientation on the dimensional accuracy of orthodontic aligners printed 3-dimensionally10.1016/j.ajodo.2021.01.018 ↗