Use of electrical resistivity of concrete in assessing state and efficiency of moist curing

Meili Li

Open full text

Abstract

Monitoring the state of moist curing of concrete can be carried out by measuring its electrical resistivity.The variation of electrical resistivity in the surfacial zone of concrete from the surface 1 to 5cm with different curing age and curing conditions was measured.Then the change of electrical resistivity in the surfacial zone of concrete specimen cured at different conditions for 28d,which was being immersed in water,was measured.Finally,the variation tendency of the electrical resistivity in different depth of the surfacial zone was compared and analyzed.It is shown that the difference between the average electrical resistivity in the depth of 1 to 2cm and that of 4-5cm could be used to indicate the curing state of concrete;the higher the difference,the poor the curing.The reduction of the electrical resistivity in a certain depth of concrete after immersing in water could be used to assess the curing efficiency;the higher the reduction,the lower the efficiency.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Concrete and Cement Materials Research · Concrete Corrosion and Durability · Concrete Properties and Behavior