Effect of process parameters on the microstructure and properties of copper film deposited by arc ion plating
Source abstract
Abstract
Copper films were deposited by pulsed bias arc ion plating technique at different levels of process parameters,such as arc current or negative substrate bias.The influences of arc current and negative substrate bias on microstructure,corrosion resistance performance,and cohesive performance of the copper films were respectively investigated by metallographic microscope,corrosion weight loss test,and bidirectional bend method.The result shows that with the arc current increasing from 40 to 80A,the grain content on the film surface increases obviously,and the large grain size grows from 13.71 to 19.36μm,meanwhile,the average corrosion rate of copper film decreases.The cohesive performance of copper films increases before decreasing with the increase of arc current,and reaches the top at 60 A.With the negative substrate bias increasing,both the grain content and the grain size decrease,while the cohesive performance of copper films increases.The effect of grain purging become considerably obvious when the negative substrate bias reach 200 V.When the negative substrate bias was increased from 20 to 180V,the average corrosion rate of copper film decreases first then increases and reaches the best at 140 V.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Metal and Thin Film Mechanics · Welding Techniques and Residual Stresses · Electrical Contact Performance and Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.