article·2009-01-01Open access

The study of amorphous SiO_x:H nanocoated on biomedical NiTi alloy by low-temperature plasma deposition

Qingsong Yu

Open full text

Abstract

Low-temperature plasma deposition technique was used to prepare amorphous SiOx∶H nanocoating on the surface of biomedical NiTi alloy.The surface chemistry and crystal structure of SiOx∶H coating were characterized.The results showed that the surface hydrophilicity and thickness of SiOx∶H nanocoating could be controlled by adjusting the flow ratio of TMS:O2 and deposition duration.The prepared plasma SiOx∶H nanocoating is amorphous structure.The optimal condition of plasma coating is TMS∶O2=1∶4ml/min,4min,D.C 5W,system pressure 3.33Pa.Under the condition,the thickness of SiOx∶H coating is about 45nm,the water contact angle on surface is about 30-40°.The corrosion resistance of NiTi alloy could be improved with plasma SiOx∶H nanocoating.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Metal and Thin Film Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References