article·2012-01-01Open access

Measurement of ultra small residual stress in deep submicron thick films by the annular thin plates

Xiaopei Zheng

Open full text

Abstract

In order to sensitive measure the small residual stress in deep submicron thick films,some improvement have been made on the annular structures,three deep submicron films of various thickness were prepared to measure the residual stress with this improved annular structures,and released in HF solution to get the critical etching length under an on line monitoring system.The critical etching length was inputted into the ANSYS software to predict the residual stress by the eigenvalue buckling analysis.Small compressive stress less than 10MPa within films were resolved successfully with this improved annular structure,but the micro rotating structures fabricated in the same die cannot generate a distinguishable deformation and failed to measure the residual stress.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Metal and Thin Film Mechanics · Advanced Surface Polishing Techniques · Welding Techniques and Residual Stresses

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References