journal article·2023-04-24Open access

Effect of Splinting on Orthodontic Mini-Implant Tipping and Bone Histomorphometric Parameters: An In Vivo Animal Model Study

Joana Fontes, Victor Zacharias Martin, Marta Resende, Bruno Colaço, Pedro de Sousa Gomes, José Manuel Amarante

Abstract

This study aimed to address the stability of orthodontic mini-implants submitted to an immediate orthodontic functional load, in splinted or unsplinted conditions, further characterizing the histomorphometric parameters of the neighboring bone tissue, in an in vivo experimental model. Mini-implants (1.4 × 6.0 mm) were placed in the proximal tibia of New Zealand White rabbits and immediately loaded with a 150 g force. Tissue healing was characterized within 8 weeks. Microtomography was used to assess the mini-implants’ tipping and bone histomorphometric indexes. Loaded implants were evaluated in splinted and unsplinted conditions, with data being compared to that of unloaded mini-implants with the Kruskal–Wallis nonparametric test, followed by Dunn’s multiple comparison tests. The splinting of mini-implants submitted to immediate orthodontic loading significantly reduced the tipping to levels similar to those of unloaded mini-implants. Immediate loading further increased the histomorphometric indexes associated with bone formation at the peri-implant region, in both splinted and unsplinted conditions, with no significant differences between the tension and compression regions. Accordingly, within this experimental setting, splinting was found to lessen tipping and mini-implants’ displacement, without affecting the increased bone formation at the peri-implant region, induced by a functional orthodontic load.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthodontics and Dentofacial Orthopedics · dental development and anomalies · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Faculty of Medicine, University of Porto, 4200-319 Porto, Portugal

BoneLab—Laboratory for Bone Metabolism and Regeneration, Faculty of Dental Medicine, University of Porto, Rua Dr. Manuel Pereira da Silva, 4200-393 Porto, Portugal

LAQV/REQUIMTE—Laboratório Associado para a Química Verde/Rede de Química e Tecnologia, University of Porto, 4100-007 Porto, Portugal

Faculty of Dental Medicine, University of Porto, 4200-393 Porto, Portugal

Department of Zootechnics, University of Trás-os-Montes and Alto Douro (UTAD), 5000-801 Vila Real, Portugal

Center for the Research and Technology of Agro-Environmental and Biological Sciences (CITAB), University of Trás-os-Montes and Alto Douro (UTAD), 5000-801 Vila Real, Portugal

Associate Laboratory for Animal and Veterinary Sciences (AL4AnimalS), 5000-801 Vila Real, Portugal

Funding

PT national funds (FCT/MCTES, Fundação para a Ciência e Tecnologia and Ministério da Ciência, Tecnologia e Ensino Superior)

References (67)

Show source-provided references
1. Orthodontic anchorage: A systematic review
2. Comparison of the effects of mini-implant and traditional anchorage on patients with maxillary dentoalveolar protrusion10.2319/051016-375.1 ↗
3. Mini-implants for orthodontic anchorage10.1038/sj.ebd.6401257 ↗
4. The application of mini-implants for orthodontic anchorage10.1016/j.ijom.2006.02.018 ↗
5. The use of miniscrew implants for temporary skeletal anchorage in orthodontics: A comprehensive review10.1016/j.tripleo.2006.11.022 ↗
6. Mini-screws success rates sufficient for orthodontic treatment10.1038/sj.ebd.6400777 ↗
7. An umbrella review of the effectiveness of temporary anchorage devices and the factors that contribute to their success or failure10.1016/j.jebdp.2020.101402 ↗
8. Risk factors associated with the stability of mini-implants and mini-plates: Systematic review and meta-analysis10.1007/s00784-021-04212-z ↗
9. Failure rates and associated risk factors of orthodontic miniscrew implants: A meta-analysis10.1016/j.ajodo.2012.05.016 ↗
10. Survival estimates and risk factors for failure of palatal and buccal mini-implants10.2319/090720-777.1 ↗
11. Risk factors for orthodontic mini-implants in skeletal anchorage biological stability: A systematic literature review and meta-analysis10.1038/s41598-020-62838-7 ↗
12. Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: A systematic review and meta-analysis10.1186/s40510-018-0225-1 ↗
13. Patient and miniscrew implant factors influence the success of orthodontic miniscrew implants10.1038/sj.ebd.6401202 ↗
14. Jedliński, M., Janiszewska-Olszowska, J., Mazur, M., Grocholewicz, K., Suárez Suquía, P., and Suárez Quintanilla, D. (2022). How Does Orthodontic Mini-Implant Thread Minidesign Influence the Stability? Systematic Review with Meta-Analysis. J. Clin. Med., 11.10.3390/jcm11185304 ↗
15. Systematic review of mini-implant displacement under orthodontic loading10.1038/ijos.2013.92 ↗
16. Displacement of mini-implants under orthodontic force loading: A systematic review10.5005/jp-journals-10015-1829 ↗
17. Can implants move in bone? A longitudinal in vivo micro-CT analysis of implants under constant forces in rat vertebrae10.1111/clr.13531 ↗
18. Becker, K., Rauch, N., Brunello, G., Azimi, S., Beller, M., Hüfner, M., Nienkemper, M., Schwarz-Herzke, B., and Drescher, D. (2021). Bone remodelling patterns around orthodontic mini-implants migrating in bone: An experimental study in rat vertebrae. Eur. J. Orthod., in press.10.1093/ejo/cjab065 ↗
19. Primary migration of a mini-implant under a functional orthodontic loading10.1007/s00784-013-1045-9 ↗
20. Mini-Implants, Mega Solutions: A Case Series10.1111/jopr.12382 ↗
21. Mini implants for definitive prosthodontic treatment: A systematic review10.1016/S0022-3913(13)60035-9 ↗
22. Effect of splinting mini-implants on marginal bone loss: A biomechanical model and clinical randomized study with mandibular overdentures
23. Stability of connected mini-implants and miniplates for skeletal anchorage in orthodontics10.1093/ejo/cjm124 ↗
24. The efficient use of midpalatal miniscrew implants
25. Improvement of mini-implant stability in orthodontics10.1051/orthodfr/2012021 ↗
26. Pranskunas, M., Šimoliūnas, E., Alksne, M., Martin, V., Gomes, P., Puisys, A., Kaupinis, A., and Juodzbalys, G. (2021). Assessment of the Bone Healing Process Mediated by Periosteum-Derived Mesenchymal Stem Cells’ Secretome and a Xenogenic Bioceramic—An In Vivo Study in the Rabbit Critical Size Calvarial Defect Model. Materials, 14.10.3390/ma14133512 ↗
27. Santiago, E., Martin, V., Colaço, B., Fernandes, M., Santos, C., and Gomes, P. (2022). Hydrothermal Synthesis of Fluorapatite Coatings over Titanium Implants for Enhanced Osseointegration—An In Vivo Study in the Rabbit. J. Funct. Biomater., 13.10.3390/jfb13040241 ↗
28. A new ex vivo model of the bone tissue response to the hyperglycemic environment–The embryonic chicken femur organotypic culture in high glucose conditions10.1016/j.bone.2022.116355 ↗
29. Animal Models for Evaluation of Bone Implants and Devices:Comparative Bone Structure and Common Model Uses10.1177/0300985815593124 ↗
30. The rabbit as experimental model for research in implant dentistry and related tissue regeneration10.3109/08941939.2013.778922 ↗
31. Comparison of the loading behavior of self-drilling and predrilled miniscrews throughout orthodontic loading10.1016/j.ajodo.2006.01.042 ↗
32. Loss of anchorage of miniscrews: A 3-dimensional assessment10.1016/j.ajodo.2007.10.059 ↗
33. Evaluation of the stability of self-drilling mini-implants for maxillary anchorage under immediate loading
34. Anchorage value of surgical titanium screws in orthodontic tooth movement10.1016/j.ijom.2006.10.020 ↗
35. Primary stability and viscoelastic displacement of mini-implant system under loading10.1016/j.clinbiomech.2016.11.004 ↗
36. Different loading strategies for dental implants: A Cochrane systematic review of randomized controlled trials
37. Indications for Splinting Implant Restorations10.1016/j.joms.2005.05.149 ↗
38. Midpalatal miniscrews for orthodontic anchorage: Factors affecting clinical success10.1016/j.ajodo.2007.11.036 ↗
39. The effect of digital diagnostic setups on orthodontic treatment planning10.1016/j.ajodo.2019.09.008 ↗
40. Francisco, I., Ribeiro, M.P., Marques, F., Travassos, R., Nunes, C., Pereira, F., Caramelo, F., Paula, A.B., and Vale, F. (2022). Application of Three-Dimensional Digital Technology in Orthodontics: The State of the Art. Biomimetics, 7.10.3390/biomimetics7010023 ↗
41. Clinical and histologic analysis of the stability of microimplants with immediate orthodontic loading in dogs10.1016/j.ajodo.2007.10.046 ↗
42. Comparison of micro-computed tomography and histomorphometry in the measurement of bone–implant contact ratios10.1016/j.oooo.2018.12.023 ↗
43. Hong, J.-M., Kim, U.-G., and Yeo, I.-S.L. (2022). Comparison of three-dimensional digital analyses and two-dimensional histomorphometric analyses of the bone-implant interface. PLoS ONE, 17.10.1371/journal.pone.0276269 ↗
44. Computer-based automatic classification of trabecular bone pattern can assist radiographic bone quality assessment at dental implant site10.1259/bjr.20180437 ↗
45. Comparison of different microCT-based morphology assessment tools using human trabecular bone10.1016/j.bonr.2020.100261 ↗
46. Osseointegration of miniscrews: A histomorphometric evaluation10.1093/ejo/cjm078 ↗
47. A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage
48. Reaction of peri-implant tissues to continuous loading of osseointegrated implants10.1016/S0889-5406(98)70211-2 ↗
49. Long-term evaluation of sandblasted and acid-etched implants used as orthodontic anchors in dog10.1016/S0889-5406(03)00629-2 ↗
50. Bone response to orthodontic loading of endosseous implants in the rabbit calvaria: Early continuous distalizing forces10.1093/ejo/21.3.223 ↗
51. Bone microdamage, remodeling and bone fragility: How much damage is too much damage?
52. The effect of force, timing, and location on bone-to-implant contact of miniscrew implants10.1093/ejo/cjn091 ↗
53. Load-related implant reaction of mini-implants used for orthodontic anchorage10.1111/j.1600-0501.2005.01149.x ↗
54. Endosseous titanium implants during and after orthodontic load-an experimental study in the dog10.1034/j.1600-0501.1993.040203.x ↗
55. Orthodontic anchorage capacity of short titanium screw implants in the maxilla. An experimental study in the dog10.1034/j.1600-0501.1997.080208.x ↗
56. Osseous adaptation to continuous loading of rigid endosseous implants10.1016/0002-9416(84)90301-4 ↗
57. The impact of healing time before loading on orthodontic mini-implant stability: A histomorphometric study in minipigs10.1016/j.archoralbio.2012.12.010 ↗
58. Micro-CT and histologic analyses of bone surrounding immediately loaded miniscrew implants: Comparing compression and tension loading10.4012/dmj.2013-223 ↗
59. Kim, J.-M., Lin, C., Stavre, Z., Greenblatt, M., and Shim, J.-H. (2020). Osteoblast-osteoclast communication and bone homeostasis. Cells, 9.10.3390/cells9092073 ↗
60. Role of angiogenesis in bone repair10.1016/j.abb.2014.07.006 ↗
61. Effect of load-induced local mechanical strain on peri-implant bone cell activity related to bone resorption and formation in mice: An analysis of histology and strain distributions10.1016/j.jmbbm.2021.104370 ↗
62. Effect of tension and compression on dynamic alveolar histomorphometry10.1016/j.jmbbm.2023.105666 ↗
63. Stress influence on orthodontic system components under simulated treatment loadings10.1016/j.cmpb.2020.105569 ↗
64. Load-related bone modelling at the interface of orthodontic micro-implants10.1111/j.1600-0501.2006.01233.x ↗
65. Effects of Mechanical Stress Stimulation on Function and Expression Mechanism of Osteoblasts10.3389/fbioe.2022.830722 ↗
66. Anatomical variations in cortical bone surface permeability: Tibia versus femur10.1016/j.jmbbm.2020.104122 ↗
67. Effects of fluid shear stress on expression of focal adhesion kinase in MG-63 human osteoblast-like cells on different surface modification of titanium10.1080/21655979.2021.1962686 ↗