Biomechanical Testing of Two-Unit Bridges and a Comparison of Replacement Retention Depending on a Cementation Medium, Replacement Position, and Gap Size
Source abstract
Abstract
Dental replacements are placed between the abutment teeth. The exceptions are two-unit bridges, as they are supported by a single tooth prepared only on one side of the missing tooth. The presented study deals with an analysis of a pressure force action on two-unit bridges placed in the frontal part (20 samples), where the pressure action is lower, and in the distal part (20 samples), where the pressure action is higher. A CAD program by 3Shape was used for digital designing with two different gap settings, 10 μm (20 samples) and 30 μm (20 samples). Two-unit bridges were attached to the prepared tooth using two types of dental cement (20/20 samples), which were selected for their physical and bioactive properties. All two-unit bridges (a total of 80 samples) were fabricated from CoCr alloys on Mlab cusing R by applying the Selective Laser Melting (SLM) technology. Mechanical testing was performed using the Inspekt5 table blue. The obtained data were used to verify the hypotheses—a difference between both types of cement (A ≠ B), a difference between the frontal and distal two-unit bridges (F ≠ D) and a difference between the gap sizes (10 ≠ 30). To confirm the given theories, data were statistically evaluated using the F-test and subsequent t-tests. The resulting p-value was compared with the level of significance (α = 0.05). A statistical evaluation revealed a significant difference between the compared groups; however, no explicit correlation between the individual groups of specimens was identified.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Additive Manufacturing and 3D Printing Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Biomedical Engineering and Measurement, Faculty of Mechanical Engineering, Technical University of Košice, 040 01 Košice, Slovakia
Clinic of Pneumology and Phthisiology, L. Pasteur University Hospital Košice, 040 11 Košice, Slovakia
Department of Applied Mathematics and Informatics, Faculty of Mechanical Engineering, Technical University of Košice, 040 01 Košice, Slovakia
Funding
Slovak Research and Development Agency
References (35)
Show source-provided references
1. Mechanical properties of dental Co-Cr alloys fabricated via casting and Selective Laser Melting
2. Mechanical performance, corrosion and tribological evaluation of a Co–Cr–Mo alloy processed by MIM for biomedical applications10.1016/j.jmbbm.2020.103706 ↗
3. Tresca stress study of CoCrMo-on-CoCrMo bearings based on body mass index using 2D computational model
4. Viderščak, D., Schauperl, Z., Šolić, S., Ćatić, A., Godec, M., Kocijan, A., Paulin, I., and Donik, Č. (2021). Additively Manufactured Commercial Co-Cr Dental Alloys: Comparison of Microstructure and Mechanical Properties. Materials, 14.10.3390/ma14237350 ↗
5. Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology10.1016/j.dental.2008.02.011 ↗
6. Rapid Prototyping Technologies and their Applications in Prosthodontics, a Review of Literature
7. Accuracy of marginal fit and axial wall contour for lithium disilicate crowns fabricated using three digital workflows10.1016/j.prosdent.2018.11.003 ↗
8. Effect of CNC-milling on the marginal and internal fit of dental ceramics: A pilot study10.1016/j.dental.2013.04.018 ↗
9. Evaluation of marginal and internal fit of ceramic crown copings10.1016/j.dental.2012.10.012 ↗
10. In vitro Evaluation of the Marginal Fit and Internal Adaptation of Zirconia and Lithium Disilicate Single Crowns: Micro-CT Comparison Between Different Manufacturing Procedures10.2174/1874210601812010160 ↗
11. Volumetric shrinkage and film thickness of cementation materials for veneers: An in vitro 3D microcomputed tomography analysis10.1016/j.prosdent.2016.08.029 ↗
12. Musleh, A.M., AbuNasser, B.S., Faraj, A.J., Awwad, A., Hamad, Y.J., Al Hour, F., and Elshanti, A. (2020, September 15). Evaluation of Marginal Gap and Internal Adaptation of All-Ceramic Coping Fabricated With CAD/CAM and Press-Laboratory Technique; an In Vitro Study. Available online: http://dspace.alazhar.edu.ps/xmlui/handle/123456789/642.
13. Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques10.4047/jap.2017.9.1.1 ↗
14. Marginal fit of all-ceramic crowns fabricated using two extraoral CAD/CAM systems in comparison with the conventional technique10.2147/CCIDE.S130856 ↗
15. Marginal and internal fit of metal copings fabricated with rapid prototyping and conventional waxing10.1016/j.prosdent.2016.04.010 ↗
16. Current status and applications of additive manufacturing in dentistry: A literature-based review10.1016/j.jobcr.2019.04.004 ↗
17. Applications of additive manufacturing in dentistry: A review10.1002/jbm.b.33961 ↗
18. Defects-tolerant Co-Cr-Mo dental alloys prepared by selective laser melting10.1016/j.dental.2015.09.003 ↗
19. Selective laser melting technique of Co-Cr dental alloys: A review of structure and properties and comparative analysis with other available techniques10.1111/jopr.12268 ↗
20. A comparative study of additive and subtractive manufacturing for dental restoration10.1016/j.prosdent.2016.11.004 ↗
21. Geometrical accuracy of metallic objects produced with additive or subtractive manu-facturing: A comparative in vitro study10.1016/j.dental.2018.03.009 ↗
22. Han, X., Sawada, T., Schille, C., Schweizer, E., Scheideler, L., Geis-Gerstorfer, J., Rupp, F., and Spintzyk, S. (2018). Comparative analysis of mechanical properties and metal-ceramic bond strength of Co-Cr dental alloy fabricated by different manufacturing processes. Materials, 22.10.3390/ma11101801 ↗
23. Comparative analysis of the microstructures and mechanical properties of Co-Cr dental alloys fabricated by different methods10.1016/j.prosdent.2017.11.015 ↗
24. A comparison of traditional manufacturing vs additive manufacturing, the best method for the job10.1016/j.promfg.2019.02.003 ↗
25. 3D metal printing technology
26. Dental materials foundations and applications
27. Pressure transmission and distribution under impact load using artificial denture teeth made of different materials10.1016/S0022-3913(09)60183-9 ↗
28. Bite Force and Influential Factors on Bite Force Measurements: A Literature Review10.1055/s-0039-1697833 ↗
29. Anusavice, K.J., Shen, C., and Rawls, H.R. (2013). Phillip’s Science of Dental Materials Health Sciences, Elsevier.
30. Effect of Surface Modifications on the Retention of Cement-retained Implant Crowns under Fatigue Loads: An In vitro Study10.4103/jpbs.JPBS_146_17 ↗
31. Guided tooth preparation device fabricated with a complete digital workflow: A dental technique10.1016/j.prosdent.2020.10.009 ↗
32. Abad-Coronel, C., Naranjo, B., and Valdiviezo, P. (2019). Adhesive Systems Used in Indirect Restorations Cementation: Review of the Literature. Dent. J., 7.10.3390/dj7030071 ↗
33. Longevity of metal-ceramic crowns cemented with self-adhesive resin cement: A prospective clinical study10.1590/1807-3107bor-2017.vol31.0022 ↗
34. Characteristic of intermetallic phases in cast dental CoCrMo alloy
35. A Comparative Assessment of Bond Strength of PEEK Crowns to Natural Teeth with Two Different Resin Cements10.11648/j.ijdm.20200601.12 ↗