The application of AC impedance technology on oxygen sensor of solid electrolyte
Source abstract
Abstract
In this article, the measuring principle of AC impedance applying for the oxygen sensor solid electrolyte was introduced, and by means of equipment of AC impedance, the samples ,which ware compounded by (Y_2O_3)_(0.08)(ZrO_2)_(0.92),sintered by Spark plasma sintering (SPS) at 1350℃10min and fried electrode at 950℃2h ,were tested. At the same time, using the ZVIEW soft the AC impedance tested result of the(Y_2O_3)_(0.08)(ZrO_2)_(0.92) samples sintered by Spark plasma sintering (SPS) and conventional sintering (CS) was fitted and the definite resistance of grain and grain boundary with measuring temperature were gotten. It show that many definite parameters which relate to the process of physics or electrochemistry in oxygen sensor solid electrolyte by means of equipment of AC impedance can been gotten and these parameter ware very helpful to definitely study the characteristic variety of oxygen sensor solid electrolyte with change of other conditions.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advancements in Solid Oxide Fuel Cells · Advanced Sensor and Control Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References
Reference metadata was not supplied for this record.