article·2006-01-01Open access

Polymer-modified fireproof coating for tunnel by redispersible powders

Yi N

Open full text

Abstract

Silicate fireproof coatings for tunnels(FCT) have many eminent properties.But lowadhesion strength and poor water/fire-resistance of this kind of materials largelyli mit its applications.Here fireproof coating for tunnels was modified by adding re-dispersible powders(2wt %).The ideal bonding systemconsisting of cement and redispersible powders could increase the adhe-sive strength with other base material and i mprove properties of water-resistance,fire-resistant ti me,weather-resisting of FCT.The polymer-modified FCT was a new kind of mono-integradient composite with easily application,and was greatly reduced thecost for transportation,storage and package.Results showthat whenthe thickness of the dry fil mis 10 mm,the fire-resistant ti meof the coating couldlast over two hours according to GA98-1995(Currency techno-termfire resistive coating for prestressed con-crete floor) and GB/T7798-88(Fire-resistance tests-elements of building construction).
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Civil and Geotechnical Engineering Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References