journal article·2025-09-08Open access

Finite Element Analysis of Trabecular-Surfaced Implants and Implant Angulation in Different Mandibular Arch Forms

Ahmet İlter Atay, Bahattin Alper Gültekin, Serdar Yalçın

Abstract

Finite element analysis is commonly used to evaluate implant biomechanics, yet limited data exist on arch form and trabecular-surfaced implants. This study aimed to investigate the biomechanical impact of a designed trabecular surface compared with a standard implant surface in full-arch, four-implant-supported restorations, using two mandibular arch forms and four placement configurations. Finite element analyses were conducted under a 250-N oblique load applied at 30° to the posterior segment. The prosthesis was modeled as a titanium–acrylic hybrid structure. Stress distribution was evaluated in cortical and cancellous bones, implants, and prosthetic frameworks. Implants with a trabecular surface demonstrated lower stress concentrations in both bone and implant structures. The von Mises stress at the neck of the posterior implant decreased from 383.3 MPa (standard implant, hyperbolic arch, configuration 1) to 194.9 MPa (trabecular-surfaced implant, U-shaped arch, configuration 4). Similarly, the average maximum principal tensile stress in cortical bone reduced from 44.32 to 40.99 MPa with the trabecular design. Among placement strategies, Configuration 3 (all implants tilted distally) yielded the highest bone stress, whereas Configurations 2 and 4 provided more favorable load distribution. Stress concentrations were also higher in hyperbolic arches, whereas U-shaped arches exhibited a more uniform distribution. These findings emphasized the biomechanical advantage of the designed trabecular surface in reducing stress across bone and implant components, indicating that trabecular titanium may represent a more reliable and cost-effective alternative for clinical applications, potentially enhancing long-term stability. Independently, the arch form and placement strategy also significantly influenced load distribution. Despite assumptions such as isotropic, homogeneous, and linearly elastic material properties, and the use of a single oblique loading condition, this study offers valuable biomechanical insights such as the stress-reducing effect of the trabecular surface, the influence of three-dimensional arch anatomy on stress concentration sites, and the necessity of selecting implant configurations according to arch forms, which may inform future full-arch implant rehabilitations.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Dental Radiography and Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Oral Implantology Program, Institute of Graduate Studies in Health Sciences, Istanbul University, 34098 Istanbul, Turkey

Faculty of Dentistry, Department of Oral Implantology, Istanbul University, 34098 Istanbul, Turkey

Funding

Scientific Research Projects Coordination Unit of Istanbul University

References (36)

Show source-provided references
1. Burden of severe periodontitis and edentulism in 2021, with projections up to 2050: The Global Burden of Disease 2021 study10.1111/jre.13337 ↗
2. Prevalence of complete edentulism among US adults 65 years and older: A Behavioral Risk Factor Surveillance System study from 2012 through 202010.1016/j.adaj.2024.02.002 ↗
3. Full-arch restoration of the jaw with fixed ceramometal prosthesis
4. Soto-Peñaloza, D., Zaragozí-Alonso, R., Peñarrocha-Diago, M., and Peñarrocha-Diago, M. (2017). The all-on-four treatment concept: Systematic review. J. Clin. Exp. Dent., 9.10.4317/jced.53613 ↗
5. Implants in the severely resorbed mandibles: Whether or not to augment? What is the clinician’s preference?10.1007/s10006-011-0285-6 ↗
6. Kloss, F.R., Kämmerer, P.W., and Kloss-Brandstätter, A. (2022). Risk factors for complications following staged alveolar ridge augmentation and dental implantation: A retrospective evaluation of 151 cases with allogeneic and 70 cases with autogenous bone blocks. J. Clin. Med., 12.10.3390/jcm12010006 ↗
7. Survival rates of axial and tilted implants in the rehabilitation of edentulous jaws using the All-on-four™ concept: A systematic review10.4103/jips.jips_100_20 ↗
8. “All-on-Four” immediate-function concept with Brånemark System® implants for completely edentulous mandibles: A retrospective clinical study10.1111/j.1708-8208.2003.tb00010.x ↗
9. Resnik, R. (2020). Misch’s Contemporary Implant Dentistry E-Book, Mosby.
10. Tilting of posterior mandibular and maxillary implants for improved prosthesis support
11. The All-on-4 treatment concept for the rehabilitation of the completely edentulous mandible: A longitudinal study with 10 to 18 years of follow-up10.1111/cid.12769 ↗
12. Ayali, A., Altagar, M., Ozan, O., and Kurtulmus-Yilmaz, S. (2020). Biomechanical comparison of the All-on-4, M-4, and V-4 techniques in an atrophic maxilla: A 3D finite element analysis. Comput. Biol. Med., 123.10.1016/j.compbiomed.2020.103880 ↗
13. The all on 4 shelf: Mandible10.1016/j.joms.2010.06.207 ↗
14. Misch, C.E. (2014). Dental Implant Prosthetics—E-Book, Mosby.10.1016/B978-0-323-07845-0.00016-6 ↗
15. Yadav, R., Sonwal, S., Sharma, R.P., Saini, S., Huh, Y.S., Brambilla, E., and Ionescu, A.C. (2024). Ranking Analysis of Tribological, Mechanical, and Thermal Properties of Nano Hydroxyapatite Filled Dental Restorative Composite Materials Using the R-Method. Polym. Adv. Technol., 35.10.1002/pat.70010 ↗
16. Development and applications of porous tantalum trabecular metal-enhanced titanium dental implants10.1111/cid.12059 ↗
17. Tantalum: A transmogrifying material in dental implant10.4103/srmjrds.srmjrds_109_20 ↗
18. Bilgin, T. (1989). Tam protezlerde kullanılan hazır ölçü kaşıkları için ülkemize uygun standartların araştırılması. Protetik Diş Tedavisi Anabilim Dalı, İstanbul Üniversitesi. Available online: https://nek.istanbul.edu.tr/ekos/TEZ/21499.pdf.
19. An overview of selected material properties in finite element modeling of the human femur10.3390/biomechanics3010012 ↗
20. Evaluation of Stress in Tilted Implant Concept with Variable Diameters in the Atrophic Mandible: Three-Dimensional Finite Element Analysis10.1563/aaid-joi-D-19-00066 ↗
21. Karacan, Ö., Keskin Yalcin, B., and Kocak Berberoglu, H. (2025, August 01). Evaluation of the Stress After Marginal Mandibular Resection With and Without Plates in Different Residual Bone Heights: A 3D Finite Element Analysis. Available online: https://papers.ssrn.com/sol3/papers.cfm?abstract_id=5205613.10.2139/ssrn.5205613 ↗
22. Assessment of the stresses produced on the bone implant/tissue interface to the different insertion angulations of the implant- a three-dimensional analysis by the finite elements’ method10.4317/jced.57387 ↗
23. Evaluation of the Relationship Between Marginal Bone Loss and Implant Angulation in All-on-Four System
24. Sevinç Gül, S.N., Murat, F., and Şensoy, A.T. (2025). Evaluation of Biomechanical Effects of Mandible Arch Types in All-on-4 and All-on-5 Dental Implant Design: A 3D Finite Element Analysis. J. Funct. Biomater., 16.10.3390/jfb16040134 ↗
25. Influence of arch shape and implant position on stress distribution around implants supporting fixed full-arch prosthesis in edentulous maxilla10.1097/ID.0b013e3181fa4267 ↗
26. Farklı Ark Formuna Sahip Maksillada Uygulanan All On Four Tedavilerinde, Anterior Bölgedeki İmplant İhtiyacının Sonlu Elemanlar Analizi ile Değerlendirilmesi10.34087/cbusbed.1628586 ↗
27. Battula, S., Papanicolaou, S., Lomicka, M., Bassett, J., and Wen, H.B. (2012). Mechanical and Interfacial Strength Evaluations of a Trabecular Metal Dental Implant Assembly. Academy of Osseointegration Annual Meeting, Academy of Osseointegration.
28. Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial10.1302/0301-620X.81B5.0810907 ↗
29. new bone formation and trabecular bone microarchitecture of highly porous tantalum compared to titanium implant threads: A pilot canine study10.1111/clr.13074 ↗
30. Zhang, L., Li, K., Pan, Q., Chen, J.C., Li, W.Y., Lv, L.H., Zhang, Y.S., and Guo, L. (2017). Biomechanical features of trabecular metal dental implants. Chin. J. Tissue Eng. Res., 21.10.1145/3127404 ↗
31. Carraro, F., and Bagno, A. (2023). Tantalum as trabecular metal for endosseous implantable applications. Biomimetics, 8.10.3390/biomimetics8010049 ↗
32. Akbarzadeh, A., Hemmati, Y., and Saleh-Saber, F. (2021). Evaluation of stress distribution of porous tantalum and solid titanium implant-assisted overdenture in the mandible: A finite element study. Dent. Res. J., 18.10.4103/1735-3327.332102 ↗
33. Micro-finite element analysis of trabecular bone yield behavior—Effects of tissue nonlinear material properties10.1142/S0219519411004010 ↗
34. Trabecular bone strength predictions using finite element analysis of micro-scale images at limited spatial resolution10.1016/j.bone.2008.11.020 ↗
35. Al Deeb, M., Aldosari, A.A., and Anil, S. (2023). Osseointegration of tantalum trabecular metal in titanium dental implants: Histological and micro-CT study. J. Funct. Biomater., 14.10.3390/jfb14070355 ↗
36. The Effect of Implant Length and Diameter on Stress Distribution of Tooth-Implant and Implant Supported Fixed Prostheses: An In Vitro Finite Element Analysis Study10.1563/aaid-joi-D-21-00023 ↗